scholarly journals A charging time energy fraction method for evaluating the performance of a latent thermal energy storage heat exchanger

Author(s):  
Wim Beyne ◽  
Kenny Couvreur ◽  
Ilya T' Jollyn ◽  
Robin Tassenoy ◽  
Steven Lecompte ◽  
...  
2021 ◽  
Vol 11 (11) ◽  
pp. 4848
Author(s):  
Hitoshi Kiyokawa ◽  
Hiroki Tokutomi ◽  
Shinichi Ishida ◽  
Hiroaki Nishi ◽  
Ryo Ohmura

Kinetic characteristics of thermal energy storage (TES) using tetrabutylammonium acrylate (TBAAc) hydrate were experimentally evaluated for practical use as PCMs. Mechanical agitation or ultrasonic vibration was added to detach the hydrate adhesion on the heat exchanger, which could be a thermal resistance. The effect of the external forces also was evaluated by changing their rotation rate and frequency. When the agitation rate was 600 rpm, the system achieved TES density of 140 MJ/m3 in 2.9 hours. This value is comparable to the ideal performance of ice TES when its solid phase fraction is 45%. UA/V (U: thermal transfer coefficient, A: surface area of the heat exchange coil, V: volume of the TES medium) is known as an index of the ease of heat transfer in a heat exchanger. UA/V obtained in this study was comparable to that of other common heat exchangers, which means the equivalent performance would be available by setting the similar UA/V. In this study, we succeeded in obtaining practical data for heat storage by TBAAc hydrate. The data obtained in this study will be a great help for the practical application of hydrate heat storage in the future.


2015 ◽  
Vol 787 ◽  
pp. 27-31
Author(s):  
M. Gajendiran ◽  
P.M. Sivaram ◽  
N. Nallusamy

In the present work the thermal performance of Phase Change Material (PCM) based solar thermal energy storage system under the influence of different heat transfer fluids (HTF) have been investigated. Water, Ethylene Glycol–water and Copper nanofluid are selected as HTF. Paraffin is used as PCM and encapsulated in cylindrical capsules. The thermal energy storage (TES) tank acts as a storage unit consisting PCM capsules packed in three beds surrounded by water, which acts as sensible heat storage (SHS) material. HTF circulated by a pump transfers heat from solar flat plate collector (FPC) to the TES tank. 25% ethylene glycol -75% water HTF is prepared by mixing ethylene glycol (EG) with water. Copper-distilled water nanofluids (0.3% by weight) are prepared using prolonged sonication with sodium dodecyl benzene sulphonate (SDBS) as the surfactant. Various performance parameters such as charging time, instantaneous heat stored, cumulative heat stored and system efficiency are studied for various HTFs. It is found that the charging time is reduced by 33.3% for copper nanofluid and 22.2% for ethylene glycol- water mixture HTFs. It is also observed that there is an increase in system efficiency and cumulative heat stored with reference to charging time for these HTFs when compared with conventional HTF 1 i.e. water.


1992 ◽  
Vol 114 (3) ◽  
pp. 204-208 ◽  
Author(s):  
R. J. Krane ◽  
M. J. M. Krane

This investigation is presented in two parts. The basic analytical model is developed in Part I. Part II includes the completion of the analytical model and the results of an optimization study performed with this model. The results show that: 1) Significant performance gains, that is, reductions in the entropy generation number on the order of 10 percent, are possible by employing perfectly stratified thermal energy storage systems that are designed on the basis of the second law of thermodynamics. 2) These performance gains are mainly due to the complete elimination of the entropy generation due to heat transfer through finite temperature differences within the storage element. 3) In general, the optimum design of a perfectly stratified thermal energy storage system requires the use of a very large heat exchanger; however, it is possible to employ a much smaller than optimum heat exchanger without seriously degrading the superior performance of the system. 4) The operation of a stratified system is quite flexible because it has no optimum storage time. 5) The optimum values of the capacity rate ratios, (φR)opt and (φR)opt, for a perfectly stratified thermal energy storage system are in general not equal to unity; however, this finding is shown to be in concert with Bejan’s theory of “remanent” irreversibilities for a heat exchanger.


2018 ◽  
Vol 70 ◽  
pp. 01010
Author(s):  
Marta Kuta ◽  
Dominika Matuszewska ◽  
Tadeusz Michał Wójcik

Increasing energy consumption in residential and public buildings requires development of new technologies for thermal energy production and storage. One of possibilities for the second listed need is the use of phase change materials (PCMs). This work is focused on solutions in this area and consists of two parts. First one is focused on different designs of thermal energy storage (TES) tanks based on the phase change materials. The second part is the analysis of tests results for TES tank containing shelf and tube heat exchanger and filled with phase change material. Thermal energy storage tank is analyzed in order to use it in domestic heating and hot utility water installations. The aim of this research was to check the applicability of phase change material for mentioned purpose. Results show that using phase change materials for thermal energy storage can increase amount of stored heat. The use of properly selected PCM and heat exchanger enables the process of thermal energy storing and releasing to become more efficient.


2020 ◽  
Vol 273 ◽  
pp. 123030
Author(s):  
Renkun Dai ◽  
Javad Mostaghimi ◽  
Nianqi Li ◽  
Tianrui Deng ◽  
Qiuwang Wang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document