Lateral retinacular release as a function of femoral component rotation in total knee arthroplasty

2004 ◽  
Vol 19 (4) ◽  
pp. 459-463 ◽  
Author(s):  
Samir Sodha ◽  
Jane Kim ◽  
Kevin J McGuire ◽  
Jess H Lonner ◽  
Paul A Lotke
2019 ◽  
Vol 33 (10) ◽  
pp. 971-977
Author(s):  
Diana K. Lee ◽  
Matthew J. Grosso ◽  
David P. Trofa ◽  
Julian J. Sonnenfeld ◽  
H. John Cooper ◽  
...  

AbstractProper femoral component rotation in total knee arthroplasty (TKA) is important, given the prognostic impact of a poorly positioned component. The purpose of this observational study was to determine the incidence of femoral component malrotation using posterior condylar axis (PCA) referencing. A total of 100 knees in 92 patients with varus gonarthritis of the knee undergoing primary TKA using a standard medial parapatellar approach were evaluated intraoperatively. After distal femoral resection, the standard femoral sizing guide referencing the posterior condylar axis was used to set femoral component rotation. This was then compared with both the transepicondylar (TEA) and trochlear anteroposterior axes (TRAx). Disparites were recorded and corrected in line with the epicondylar axis. Rotational adjustment for addition of further external rotation was made in 13 (13.0%) cases. In seven cases, the medial pin sites were raised between 1 and 3 mm, and in six cases, the lateral pin site was lowered between 1 and 3 mm (based on risk of notching the femoral cortex). It is critical to not rely exclusively on the PCA to confirm rotational positioning of the femoral component as predicted by posterior condylar referencing guides. Intraoperative adjustment and confirmation using the TEA and TRAx occurred in 13% of primary TKA cases, which might have, otherwise, had a significant effect on the clinical outcome.


2014 ◽  
Vol 2 (11_suppl3) ◽  
pp. 2325967114S0014
Author(s):  
Harun Reşit Güngör ◽  
Nusret Ök ◽  
Kadir Ağladıoğlu ◽  
Semih Akkaya ◽  
Esat Kıter

Objectives: Pertaining to peculiar designs of current knee prostheses, more bone is removed from posteromedial femoral condyle than posterolateral condyle to obtain desired femoral component rotation. The aim of our study was to evaluate whether there is a correlation between the asymmetry of the cuts and the femoral component rotation in total knee arthroplasty. Methods: We built a model to simulate anterior chamfer cut (ACC) performed during total knee arthroplasty for measuring posterior condylar offset (PCO). Right knee axial MRI slices of a total 290 consecutive patients (142 male, 138 female, and mean age 31.39 ± 6.6) were examined. A parallel line to surgical transepiphyseal axis was drawn, and placed at the deepest part of trochlear groove. Posteromedial and posterolateral condylar offsets were measured by drawing perpendicular lines to ACC beginning from the intersection points of both anteromedial and anterolateral cortices to posterior joint line (PJL), respectively. Differences between posteromedial and posterolateral PCO were calculated, and femoral rotation angles (FRA) relative to PJL were measured. Results: The mean surgical FRA was 4.76 ± 1.16 degrees and the mean PCO differencesss- was 4.35 ± 1.04 mm for the whole group and there was no statistically significant difference between genders. There was a strong correlation between surgical FRA and PCO difference (p<0.0001, r=0.803). Linear regression analyses revealed that 0.8 mm of difference between the anteroposterior dimensions of medial and lateral PCO corresponds to 1 degree of surgical FRA (p<0.0001, R2=0.645). Conclusion: Correlation between the asymmetry of posterior chamfer cuts and achieved femoral component rotation can verify the accuracy of desired rotation, intraoperatively. However, further clinical investigations should be planned to test the results of our morphometric study.


2012 ◽  
Vol 36 (10) ◽  
pp. 2067-2072 ◽  
Author(s):  
Anna Rienmüller ◽  
Thomas Guggi ◽  
Gerald Gruber ◽  
Stefan Preiss ◽  
Tomas Drobny

Sign in / Sign up

Export Citation Format

Share Document