Long-Term Clinical Outcomes and Survivorship After Total Knee Arthroplasty Using a Rotating Platform Knee Prosthesis

2013 ◽  
Vol 28 (1) ◽  
pp. 68-77.e3 ◽  
Author(s):  
Colin D.J. Hopley ◽  
Lawrence S. Crossett ◽  
Antonia F. Chen
Author(s):  
Ahmed A. Khalifa ◽  
Mostafa Fayez ◽  
Hesham Elkady ◽  
Ahmed M. Abdelaal ◽  
Maher A. Elassal

AbstractPosterior-stabilized, rotating platform knee prosthesis design was aimed to decrease polyethylene wear for the sake of improving implant survivorship. The purpose of the present prospective study was to evaluate the long-term clinical and radiographic results as well as the survival rate after using a rotating platform, posterior-stabilized knee prosthesis at a minimum of 10 years at a Middle East institution. We compared the results with reports in the literature on western populations. From January 2002 to June 2008, 96 patients (106 knees) underwent total knee arthroplasty (TKA) using a cemented rotating platform posterior-stabilized knee prosthesis. At a mean of 11.5 ± 1.3 years, 85 patients (95 TKAs) were available for clinical, radiographic, and implant survival analysis. At the final follow-up, 78.9% of the patients had excellent Knee Society Scoring system score, the average knee flexion was 110 ± 17 degrees, the average anatomical knee coronal alignment was 186 ± 2 degrees and 187 ± 3 degrees for varus and valgus knees, respectively. Five (5.2%) knees were revised of these: two for bearing dislocation, two for aseptic loosening, and one for infection. The Kaplan-Meier survival rate was 94.7% for all revisions and 97.8% when only revision for aseptic loosening considered as the end point. At a long-term follow-up, reasonable clinical and radiographic outcomes had been achieved after using a rotating platform, posterior-stabilized knee prosthesis in our population with acceptable survival rate reaching up to 95%, which is comparable to reports from the western population.


10.29007/3724 ◽  
2018 ◽  
Author(s):  
Eun-Kyoo Song ◽  
Jong-Keun Seon ◽  
Dong-Hyun Lee ◽  
Je-Hyoung Yeo

Total knee arthroplasty using navigation system is known to be more effective than conventional methods in achieving more accurate bone resection and neutral alignment.1 Mobile bearing is also known to reduce wear and automatically correct rotational malalignment of the tibia but the long-term follow-up results of more than 10 years are extremely rare.2, 3 The purpose of this study is to investigate the results of clinical and radiologic long-term follow-up and complications of total knee arthroplasty using navigation and multi-directional mobile bearing.From 2003 to 2006, a total of 111 navigation TKAs using multi-directional mobile bearing design were carried out and reviewed retrospectively. TKAs were performed by two experienced surgeons at one institute. Of the 111 patients, 102 were women and 9 were men. The mean duration of follow-up was 11.4 ± 1.0 years (range, 10.1 to 14.08 years). Clinical outcomes were evaluated in terms of Knee Society Score, Hospital for Special Surgery score, Western Ontario and McMaster University (WOMAC) score, range of motion and complications. Long-term radiological outcomes and survival rates were evaluated at least 10 years.Average preoperative HSS score was 66.5 ± 9.8 and KSS pain and function score were 25.0 ± 11.8 and 44.5 ± 12.3, respectively. Scores improved to 94.1 ± 8.2, 46.6 ± 11.6 and 88.2 ± 14.6 at the last follow up, respectively. Mean preoperative WOMAC scores of 75.8 ± 16.5 improved to 13.8 ± 16.0 at last follow-up. Five knees required re-operation, two for liner breakage, one for liner wear, one for distal femoral fracture and one for infection. The estimated 10-year prosthesis survival rates for any reason and for prosthesis-related problems were 95.5% and 97.4% , respectively.TKAs using each techniques resulted in similar good clinical outcomes and postoperative leg alignments. Robotic and navigation TKA appeared to reduce the number of postoperative leg alignment outliers and revision rate compared to conventional TKA.


Author(s):  
Kaiyang Wang ◽  
Fang Fang Zhang ◽  
Xu Yan ◽  
Yifan Shen ◽  
Weijie Cai ◽  
...  

AbstractAs more patients undergo total knee arthroplasty (TKA) each year, and the average age of patients gets younger, the patients are generally more active requiring a greater physiological demand and increasing range of motion on the prosthesis than the previous patients. However, there is no consensus on the optimal TKA tibial bearing design. We performed this systematic review to compare the clinical differences between mobile and fixed bearing constructs used in contemporary TKA. We searched PubMed, EMBASE, and Cochrane Library databases, identifying 515 total publications, including 17 randomized controlled trials (RCTs). A meta-analysis was performed, while the quality and bias of the evidence were rated according to the Grading of Recommendations Assessment Development and Evaluation (GRADE) guidelines and the Cochrane Database questionnaire. The meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Seventeen studies were included, with a total of 1505 knees receiving a mobile bearing TKA and 1550 knees receiving a fixed bearing TKA. The meta-analysis compared clinical outcomes between mobile bearing (MB)-TKA and fixed bearing (FB)-TKA using postoperative Knee Society Score, postoperative ROM, and survivorship and showed that there was a distinct difference in Knee Society Score between the mobile-bearing and fixed-bearing groups (overall standardized mean difference = 1.38; 95% confidence interval (CI): 0.50–2.25; p = 0.002; I2 = 60%). Patients treated with mobile-bearing prostheses were more likely to report good or excellent range of motion results (overall standardized mean difference = 2.06; 95% CI: 0.65–3.47; p = 0.004). No difference in implant survivorship or reoperation rate were identified. The fixed-bearing and mobile-bearing TKA designs are both capable of producing excellent long-term results with excellent clinical outcomes if properly implanted; however, the mobile-bearing TKA have superiority in mid- to long-term clinical results. Trial registration number for PROSPERO was CRD42019126402.


The Knee ◽  
2020 ◽  
Vol 27 (6) ◽  
pp. 1778-1786
Author(s):  
Hideki Ueyama ◽  
Narihiro Kanemoto ◽  
Yukihide Minoda ◽  
Nobuo Yamamoto ◽  
Yoshiki Taniguchi ◽  
...  

2020 ◽  
Vol 102-B (6_Supple_A) ◽  
pp. 36-42
Author(s):  
Kohei Nishitani ◽  
Shinichi Kuriyama ◽  
Shinichiro Nakamura ◽  
Naoki Umatani ◽  
Hiromu Ito ◽  
...  

Aims This study aimed to evaluate the association between the sagittal alignment of the femoral component in total knee arthroplasty (TKA) and new Knee Society Score (2011KSS), under the hypothesis that outliers such as the excessive extended or flexed femoral component were related to worse clinical outcomes. Methods A group of 156 knees (134 F:22 M) in 133 patients with a mean age 75.8 years (SD 6.4) who underwent TKA with the cruciate-substituting Bi-Surface Knee prosthesis were retrospectively enrolled. On lateral radiographs, γ angle (the angle between the distal femoral axis and the line perpendicular to the distal rear surface of the femoral component) was measured, and the patients were divided into four groups according to the γ angle. The 2011KSSs among groups were compared using the Kruskal-Wallis test. A secondary regression analysis was used to investigate the association between the 2011KSS and γ angle. Results According to the mean and SD of γ angle (γ, 4.0 SD 3.0°), four groups (Extended or minor flexed group, −0.5° ≤ γ < 2.5° (n = 54)), Mild flexed group (2.5° ≤ γ < 5.5° (n = 63)), Moderate flexed group (5.5° ≤ γ < 8.5° (n = 26)), and Excessive flexed group (8.5° ≤ γ (n = 13)) were defined. The Excessive flexed group showed worse 2011KSSs in all subdomains (Symptoms, Satisfaction, Expectations, and Functional activities) than the Mild flexed group. Secondary regression showed a convex upward function, and the scores were highest at γ = 3.0°, 4.0°, and 3.0° in Satisfaction, Expectations, and Functional activities, respectively. Conclusion The groups with a sagittal alignment of the femoral component > 8.5° showed inferior clinical outcomes in 2011KSSs. Secondary regression analyses showed that mild flexion of the femoral component was associated with the highest score. When implanting the Bi-Surface Knee prosthesis surgeons should pay careful attention to avoiding flexing the femoral component extensively during TKA. Our findings may be applicable to other implant designs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):36–42.


2019 ◽  
Vol 33 (05) ◽  
pp. 513-524 ◽  
Author(s):  
Corey Scholes ◽  
Milad Ebrahimi ◽  
Nalan Ektas ◽  
John Ireland

AbstractThere is a lack of clinical outcomes reported for the rotating bearing knee (RBK) total knee arthroplasty (TKA), which is a second-generation rotating platform knee, with purported benefits over earlier versions. The purpose of the study was to report the complications, short-term (minimum 1 year) patient-reported outcomes and long-term (up to 15 years) procedure survival in a consecutive series of patients receiving a rotating platform TKA (RBK) from an independent clinic. A retrospective analysis of a single-surgeon, private/public practice, with prospectively collected data in a subset of patients were performed. A total of 1,130 procedures (primary, revision from unicompartmental knee arthroplasty (UKA) to TKA) were crossmatched with manufacturer records. Clinical outcomes (complications, reoperations) were summarized and linked to patient-reported outcome measures (Eq. 5D, KSS-function, Oxford knee score [OKS]). OKS results were classified using minimally clinical important difference (MCID) and patient acceptable symptom state (PASS). PROMs were summarized and regression models used to determine relationships between patient factors and outcomes in this cohort. Cumulative percent revision was reported by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) and compared between the senior author and national data using Kaplan–Meier survival analysis. We report a complication rate of 19.7% with the majority (> 60%) being thromboembolic events and complaints of stiffness. Significant improvements were observed in general health, knee pain, and function with > 89% exceeding the MCID for the OKS and > 65% exceeding the PASS for the OKS at an average follow-up of 3.2 years. We report a cumulative revision rate of 4.3% at 5 years and 4.8% at 14 years, with significantly lower revision rates in females and patients aged 55 to 64 years compared with AOANJRR data for fixed bearing designs. The RBK rotating platform TKA provides good functional outcomes, with relatively low revision and complications rates at up to 14 years follow-up. This design in conjunction with a gap balancing technique may be advantageous in certain patient subgroups.


Author(s):  
Tejbir S. Pannu ◽  
Jesus M. Villa ◽  
Eric M. Cohen ◽  
Roman A. Hayda ◽  
Carlos A. Higuera ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document