A Long-Term Survivorship Comparison Between Cemented and Uncemented Cups With Shelf Grafts in Revision Total Hip Arthroplasty After Dysplasia

2013 ◽  
Vol 28 (2) ◽  
pp. 303-308 ◽  
Author(s):  
Amir Sternheim ◽  
Mansour Abolghasemian ◽  
Oleg A. Safir ◽  
David Backstein ◽  
Allan E. Gross ◽  
...  
2021 ◽  
pp. 112070002110043
Author(s):  
Antonios A Koutalos ◽  
Sokratis Varitimidis ◽  
Konstantinos N Malizos ◽  
Theofilos Karachalios

Purpose: The aim of the study was to systematically evaluate clinical outcomes of tapered fluted stems, either monoblock or modular, in revision total hip arthroplasty. Methods: PubMed, EMBASE and Web of Science and Cochrane databases were systematically searched by 2 researchers. Clinical studies reporting primarily on survival and re-revision rates, and secondarily on subsidence, dislocation, intraoperative fractures, periprosthetic fractures and infection were included. 2 investigators assessed the quality of the studies. Results: 46 studies were included in this review, reporting on 4601 stem revisions. The pooled re-revision rate was 5.1% and long-term survival ranged from 75% to 98.5%. No differences were observed between monoblock and modular stems regarding re-revision rate, dislocation rate, periprosthetic fracture rate or infection rates. Monoblock stems exhibited more subsidence and modular stems displayed more intraoperative fractures. Conclusions: Satisfactory results can be obtained with the use of tapered fluted end-bearing stems. Monoblock stems offer the same clinical results as modular stems.


2020 ◽  
Author(s):  
Kai Zheng ◽  
Ning Li ◽  
Weicheng Zhang ◽  
Jun Zhou ◽  
Yaozeng Xu ◽  
...  

Abstract Background: Revision total hip arthroplasty is frequently accompanied by bone loss. The purpose of this study is to evaluate mid- to long-term results of revision total hip arthroplasty for massive femoral bone loss using cementless modular, fluted, tapered stems.Methods: During the period of 2007 to 2015 at a single hospital, 34 hips (33 patients) underwent primary revision surgery with cementless modular, fluted, tapered stems due to massive bone loss, and patients with prosthetic joint infection (PJI) or tumours were excluded. The hips were revised with the LINK MP (Waldemar Link, Hamburg, Germany) prosthesis. Bone loss was categorized by the Paprosky classification for prosthesis loosening and Vancouver classification for peri-prosthetic fracture. All revision bearing surfaces were ceramic-on-ceramic (CoC). Clinical outcomes, radiographic outcomes and survivorship were evaluated.Results: The mean follow-up was 9.1±2.5 years (range, 5-13 years). The Harris hip score was 43.6±11.5 preoperatively and maintained at 86.5±6.6 at the time of latest follow-up (p<0. 05). The X-ray showed bone ingrowth fixation in 30 hips (88%), fibrous stable fixation in 3 hips (9%) and instability in 1 hip (3%). The average stem subsidence was 3.9±2.2 mm (range, 1 to 10 mm). The survivorship of prostheses with re-revision for any reason was 95% (95% CI, 12.0 to 13.0) at the 10-year follow-up. Three (9%) re-revisions were needed, including 1 for aseptic loosening, 1 for dislocation and 1 for infection.Conclusions: The mid- to long-term results of revision total hip arthroplasty with the cementless modular, fluted, tapered stem (LINK MP stem) are encouraging for massive femoral bone loss.


2020 ◽  
Vol 35 (12) ◽  
pp. 3697-3702
Author(s):  
Charles N. Wallace ◽  
Justin S. Chang ◽  
Babar Kayani ◽  
Peter D. Moriarty ◽  
Jenni E. Tahmassebi ◽  
...  

2018 ◽  
Vol 43 (10) ◽  
pp. 2279-2284 ◽  
Author(s):  
Yannick Herry ◽  
Anthony Viste ◽  
Hugo Bothorel ◽  
Romain Desmarchelier ◽  
Michel-Henri Fessy

Arthroplasty ◽  
2019 ◽  
Vol 1 (1) ◽  
Author(s):  
Seung-Jae Lim ◽  
Ingwon Yeo ◽  
Chan-Woo Park ◽  
Kyung-Jae Lee ◽  
Byung-Woo Min ◽  
...  

Abstract Purpose Highly cross-linked polyethylene has been introduced to decrease osteolysis secondary to polyethylene wear debris generation. However, few long-term data on revision total hip arthroplasty (THA) using highly cross-linked polyethylene liners are available. The objective of this study was to determine long-term outcomes of a highly cross-linked polyethylene liner in revision THA. Materials & methods We evaluated 63 revision THAs performed in 63 patients using a highly cross-linked polyethylene liner between April 2000 and February 2005. Of these, nine died and four were lost to follow-up. Thus, the final study cohort consisted of 50 patients (50 hips), including 26 males and 24 females with a mean age of 53 years (range, 27–75 years). Mean follow-up was 11 years (range, 10–14 years). Results The mean Harris hip score improved from 44 points preoperatively to 85 points at the final follow-up. No radiographic evidence of osteolysis was found in any hip. The mean rate of polyethylene liner wear was 0.029 mm/year (range, 0.003 to 0.098 mm/year). A total of 5 hips (10%) required re-revision arthroplasty, including one cup loosening, one recurrent dislocation, and three deep infections. Kaplan-Meier survivorship with an end point of re-revision for any reason was 91.1% and for aseptic cup loosening was 97.9% at 11 years. Conclusion At a minimum of 10 years, the highly cross-linked polyethylene liners showed excellent clinical performance and implant survivorship, and were not associated with osteolysis in our patients with revision THAs.


2012 ◽  
Vol 94 (12) ◽  
pp. e82-1-8 ◽  
Author(s):  
Hilal Maradit Kremers ◽  
James L Howard ◽  
Youlonda Loechler ◽  
Cathy D Schleck ◽  
William S Harmsen ◽  
...  

2020 ◽  
Vol 35 (9) ◽  
pp. 2573-2580
Author(s):  
Brandon R. Bukowski ◽  
Nicholas J. Clark ◽  
Michael J. Taunton ◽  
Brett A. Freedman ◽  
Daniel J. Berry ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document