Anisotropic buckypaper through shear-induced mechanical alignment of carbon nanotubes in water

Carbon ◽  
2014 ◽  
Vol 80 ◽  
pp. 433-439 ◽  
Author(s):  
Danny Vennerberg ◽  
Michael R. Kessler
Author(s):  
V. Beck

Recently a number of experiments have been carried out on a STEM which included a multipole corrector for primary spherical aberration. The results of these experiments indicate that the correction of primary spherical aberration with magnetic multipoles is beset with very serious difficulties related to hysteresis.The STEM and corrector have been described previously. In theory, the corrector should cancel primary spherical aberration so that other aberrations limit the resolution. For this instrument, secondary spherical aberration should limit the resolution to 1 A at 50 kV. A thorough study of misalignment aberrations was made. The result of the study indicates that the octopoles must be aligned to 1000 A. Since mechanical alignment cannot be done to this accuracy, trim coils were built into the corrector in order to achieve the required alignment electrically. The trim coils are arranged to excite all the lower order moments of an element.


Author(s):  
Jun Jiao

HREM studies of the carbonaceous material deposited on the cathode of a Huffman-Krätschmer arc reactor have shown a rich variety of multiple-walled nano-clusters of different shapes and forms. The preparation of the samples, as well as the variety of cluster shapes, including triangular, rhombohedral and pentagonal projections, are described elsewhere.The close registry imposed on the nanotubes, focuses attention on the cluster growth mechanism. The strict parallelism in the graphitic separation of the tube walls is maintained through changes of form and size, often leading to 180° turns, and accommodating neighboring clusters and defects. Iijima et. al. have proposed a growth scheme in terms of pentagonal and heptagonal defects and their combinations in a hexagonal graphitic matrix, the first bending the surface inward, and the second outward. We report here HREM observations that support Iijima’s suggestions, and add some new features that refine the interpretation of the growth mechanism. The structural elements of our observations are briefly summarized in the following four micrographs, taken in a Hitachi H-8100 TEM operating at an accelerating voltage of 200 kV and with a point-to-point resolution of 0.20 nm.


Nature China ◽  
2007 ◽  
Author(s):  
Rachel Pei Chin Won
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document