Effect of disinfectant residual on the interaction between bacterial growth and assimilable organic carbon in a drinking water distribution system

Chemosphere ◽  
2018 ◽  
Vol 202 ◽  
pp. 586-597 ◽  
Author(s):  
Weiying Li ◽  
Junpeng Zhang ◽  
Feng Wang ◽  
Lin Qian ◽  
Yanyan Zhou ◽  
...  
2005 ◽  
Vol 71 (12) ◽  
pp. 8611-8617 ◽  
Author(s):  
Adam C. Martiny ◽  
Hans-Jørgen Albrechtsen ◽  
Erik Arvin ◽  
Søren Molin

ABSTRACT In a model drinking water distribution system characterized by a low assimilable organic carbon content (<10 μg/liter) and no disinfection, the bacterial community was identified by a phylogenetic analysis of rRNA genes amplified from directly extracted DNA and colonies formed on R2A plates. Biofilms of defined periods of age (14 days to 3 years) and bulk water samples were investigated. Culturable bacteria were associated with Proteobacteria and Bacteriodetes, whereas independently of cultivation, bacteria from 12 phyla were detected in this system. These included Acidobacteria, Nitrospirae, Planctomycetes, and Verrucomicrobia, some of which have never been identified in drinking water previously. A cluster analysis of the population profiles from the individual samples divided biofilms and bulk water samples into separate clusters (P = 0.027). Bacteria associated with Nitrospira moscoviensis were found in all samples and encompassed 39% of the sequenced clones in the bulk water and 25% of the biofilm community. The close association with Nitrospira suggested that a large part of the population had an autotrophic metabolism using nitrite as an electron donor. To test this hypothesis, nitrite was added to biofilm and bulk water samples, and the utilization was monitored during 15 days. A first-order decrease in nitrite concentration was observed for all samples with a rate corresponding to 0.5 × 105 to 2 × 105 nitrifying cells/ml in the bulk water and 3 × 105 cells/cm2 on the pipe surface. The finding of an abundant nitrite-oxidizing microbial population suggests that nitrite is an important substrate in this system, potentially as a result of the low assimilable organic carbon concentration. This finding implies that microbial communities in water distribution systems may control against elevated nitrite concentrations but also contain large indigenous populations that are capable of assisting the depletion of disinfection agents like chloramines.


2011 ◽  
Vol 383-390 ◽  
pp. 4031-4037
Author(s):  
Deng Ling Jiang ◽  
Guo Wei Ni ◽  
Yan Hua Chen ◽  
Qing Jie Zhu

The content of assimilable organic carbon (AOC) has been proposed to control the growth of heterotrophic microbe in drinking water distribution systme. However, recent results have shown that there are regions where it is predominantly phosphorus which determines the extent of microbial growth in drinking water. The growth of bacteria was studied in a drinking water distribution system where the content of AOC was high (40.84- 551.35 μg acetate-C/L) and the content of Microbially Available Phosphorus (MAP) was also high (0.69-8.01 μg PO43--P/L). It was AOC other than phosphorus that controlled the growth of bacteria in the drinking water distribution system. Comparably obvious linear relationship was found between the maximum HPC and the maximum content of AOC of the distribution system. Removal of organic matters is ideal approach to control water quality of the drinking water distribution system.


1997 ◽  
Vol 35 (8) ◽  
pp. 37-44 ◽  
Author(s):  
A. Sathasivan ◽  
S. Ohgaki ◽  
K. Yamamoto ◽  
N. Kamiko

Conventionally organic carbon is assumed to be the limiting nutrient of regrowth. Inorganic phosphorus in comparison to carbon should be a good candidate for regrowth control because it can be measured and controlled. It may be able to limit regrowth in drinking water distribution systems. In order to clarify whether inorganic phosphorus can really control or limit regrowth, three kinds of bioassays were performed: 1. for different combinations of acetate, phosphorus, and other inorganic nutrients added to different test tubes containing pure water, 2. for different tap water dilutions with pure water, and 3. for different phosphorus addition to test tubes containing all nutrients but phosphorus. The inoculum used was taken from a drinking water distribution system carrying chlorinated groundwater. Results indicated the following: 1. tap water bacteria cannot grow on simple organic carbon source (acetate) alone, 2. not organic carbon but inorganic nutrients limited the growth in tap water, and 3. tap water bacterial growth was suppressed when phosphorus was not present and it was not affected by over-presence of phosphorus when carbon or other nutrients became limiting. This gave a clue that phosphorus might play a major role in controlling regrowth in drinking water distribution system.


2009 ◽  
Vol 43 (20) ◽  
pp. 5005-5014 ◽  
Author(s):  
Jeffrey G. Szabo ◽  
Christopher A. Impellitteri ◽  
Shekar Govindaswamy ◽  
John S. Hall

2007 ◽  
Vol 2007 (1) ◽  
pp. 449-467
Author(s):  
Stacia L. Thompson ◽  
Elizabeth Casman ◽  
Paul Fischbeck ◽  
Mitchell J. Small ◽  
Jeanne M. VanBriesen