Stability of Class II corrections with removable and fixed functional appliances: A literature review

2020 ◽  
Vol 9 (2) ◽  
pp. 56-67
Author(s):  
Alexandre Moro ◽  
Camila F.P. Mattos ◽  
Suelen W. Borges ◽  
Carlos Flores-Mir ◽  
Francielle Topolski
2017 ◽  
Vol 1 (1) ◽  
Author(s):  
Aakash Shah ◽  
Purvesh Shah ◽  
Santosh Goje ◽  
Romil Shah ◽  
Bhumi Modi

2021 ◽  
pp. 030157422096341
Author(s):  
Jamoy James ◽  
Payal Ostwal ◽  
Juhi Notra

The Forsus appliance is one of the most commonly used rigid fixed functional appliances in the correction of class II malocclusion. It is often seen that parts go missing with regular usage of the appliance. Replacement of the same is expensive and also requires a large inventory. An innovative low-cost and easy option for lost or broken split crimps is described in this article.


2021 ◽  
pp. 030157422110054
Author(s):  
Prachi Gohil ◽  
Sonali Mahadevi ◽  
Bhavya Trivedi ◽  
Neha Assudani ◽  
Arth Patel ◽  
...  

We are in the process of discovery of new vistas for technological advances in terms of various appliances with a vision of making orthodontic treatment compliance free as well as successful. Due to improved technology, the enigma of treating the Class II syndrome is palliated. “Out of the box” thinking has become a norm to treat certain situations that were not corrected in noncompliant patients. Fixed functional appliances are valuable tools introduced to assist the correction of skeletal Class II malocclusion with mandibular retrognathia at the deceleration stage of growth for achieving stable results. In this direction a case series is reported of patients having the above conditions and undergoing orthodontic treatment using a Forsus FFA. Joining hands with technology is a win-win situation for both the patient and the orthodontist.


2018 ◽  
Vol 8 (1) ◽  
pp. 63-67
Author(s):  
Luv Agarwal ◽  
Kamlesh Singh ◽  
Ragni Tandon

Correction of skeletal Class II malocclusion has become a major challenge for orthodontists. Class II jaw discrepancies characterized by mandibular deficiency are treated with fixed functional appliances when there is no active growth present. This case report illustrates the application of PowerScope in 16 years young adolescent male having skeletal Class II Div 2 with mandibular deficiency who was reported with forwardly and irregularly placed upper front teeth with closed bite. The case was treated initially with MBT 0.022” prescription followed by PowerScope. Successful results were obtained with a substantial improvement in facial profile, skeletal jaw relationship and overall aesthetic appearance. PowerScope produced a significant forward movement of mandible which obliterated the need of extractions


Sign in / Sign up

Export Citation Format

Share Document