In vivo kinematics of fixed-bearing total ankle arthroplasty

2020 ◽  
Vol 26 (4) ◽  
pp. 371-377 ◽  
Author(s):  
Gloria Casaroli ◽  
Tomaso Villa ◽  
Alberto Bianchi ◽  
Eleonora Caboni ◽  
Francesco Malerba ◽  
...  
2011 ◽  
Vol 44 (6) ◽  
pp. 995-1000 ◽  
Author(s):  
Satoshi Yamaguchi ◽  
Yasuhito Tanaka ◽  
Shinichi Kosugi ◽  
Yoshinori Takakura ◽  
Takahisa Sasho ◽  
...  

2012 ◽  
Vol 45 (12) ◽  
pp. 2103-2108 ◽  
Author(s):  
Satoshi Yamaguchi ◽  
Yasuhito Tanaka ◽  
Scott Banks ◽  
Shinichi Kosugi ◽  
Takahisa Sasho ◽  
...  

2013 ◽  
Vol 95 (11) ◽  
pp. 1002-1011 ◽  
Author(s):  
Karl M. Schweitzer ◽  
Samuel B. Adams ◽  
Nicholas A. Viens ◽  
Robin M. Queen ◽  
Mark E. Easley ◽  
...  

2018 ◽  
Vol 40 (2) ◽  
pp. 131-138 ◽  
Author(s):  
Barbara H. Currier ◽  
Paul J. Hecht ◽  
James A. Nunley ◽  
Michael B. Mayor ◽  
John H. Currier ◽  
...  

Background: Although advances in joint-replacement technology have made total ankle arthroplasty a viable treatment for end-stage arthritis, revision rates for ankle replacements are higher than in hip or knee replacements. The questions asked in this study were what can retrieved ankle devices demonstrate about ankle arthroplasty failures and how can understanding the causes of these failures inform clinical decisions for current and future ankle arthroplasty patients? Methods: An IRB-approved retrieval laboratory received retrieved components and surgeon-supplied reason for revision from 70 total-ankles (7 designs, including 5 currently marketed designs) from 2002 to 2018. These retrievals were rated for clinical wear and damage. Metal components were rated by method and effectiveness of fixation. Polyethylene inserts received by the laboratory 6 months or less after retrieval (n = 45) were analyzed for oxidation using Fourier transform infrared spectroscopy. Statistical analysis was performed using IBM SPSS, version 22. Results: The ankle implants were retrieved most commonly for loosening and polyethylene fracture. Loosening occurred more frequently in fixed-bearing designs (n = 18) than in the mobile-bearing designs (n = 4) and after shorter in vivo time (mean in vivo time to retrieval for loosening: fixed bearing 3.2 ± 2.1 years, mobile bearing 9.7 ± 4.5 years). Gamma-sterilized ankle inserts oxidized at a higher rate than non-gamma (EtO or gas-plasma) sterilized ankle inserts (gamma 0.29 ± 0.22/y, non-gamma 0.07 ± 0.05/y, mean difference=0.215, 95% CI 0.128-0.303, P < .001). The presence of clinical fatigue (cracking and/or delamination) of the polyethylene insert correlated with measured oxidation (Spearman rho = 0.685, P < .001). Nine inserts, all gamma-sterilized, fractured in vivo. Conclusions: This study suggests that loosening could be more of a problem in fixed-bearing devices than in mobile bearing devices. Gamma-sterilized polyethylene inserts were found to suffer fatigue damage or fracture in vivo, resulting in the need for revision. Retrieval analysis can provide insight into implant-related reasons for revision, with the goal of understanding the implant-related causes of these failures, informing future ankle design and clinical decisions for current and future ankle arthroplasty patients. Level of Evidence: Level III, comparative series.


2019 ◽  
Vol 4 (2) ◽  
pp. 2473011419S0000
Author(s):  
James Lachman ◽  
Michel Taylor ◽  
Elizabeth Cody ◽  
Daniel Scott ◽  
James A. Nunley ◽  
...  

Category: Ankle Arthritis Introduction/Purpose: The Scandinavian Total Ankle Replacement(STAR) system and Salto Talaris(ST) total ankle system are two of the more commonly studied total ankle implants. As the STAR is one of the oldest total ankle arthroplasty (TAA) implants still in use today, most studies focus on longevity and survivorship. Reported rates of cyst formation for these two prosthesis in most series vary from 11-22% but no large study has focused on surgical management of these cysts or included patient reported outcomes after surgery. In this series, we aimed to investigate rates of cyst formation between mobile(MB) and fixed-bearing(FB) TAA and examine clinical and patient reported outcomes of bone grafting or cementing of large cysts surrounding the STAR and ST implants. Methods: A prospectively collected database at a high volume total ankle replacement center was retrospectively reviewed to identify patients who underwent TAA with either the STAR or the ST total ankle system between 2007 and 2015. Cysts were identified and measured on standard weight bearing radiographs and confirmed on computed tomography(CT) when available. Visual analog scale (VAS) score, Short Form-36 (SF-36) physical and mental component scores, Short Musculoskeletal Function Assessment(SMFA), and AOFAS hindfoot scores were collected from all patients preoperatively and then at 6 months, 1 year and annually postoperatively. Patients with a minimum 2 years follow-up who underwent revision TAA secondary to catastrophic bone cysts or who were managed with either curettage and bone grafting or curettage and cementing of bone cysts surrounding the TAA prosthesis were included in the patient reported outcomes (PRO) analysis Results: Excluding 53 patients for inadequate follow-up, 232 patients (29% female, 71% male; follow-up 6.7 years) who underwent STAR-TAA and 147 patients (26.6% female, 73.5% male; follow-up 7 years) who underwent ST-TAA were identified. Cysts <20 mm diameter occurred more often in the MB TAAs, and more often in the tibia than talus (table). Cysts >10 mm were identified in 95/232 (41%) STAR and 24/147 (16%) ST ankles. In the STAR group, 24 patients underwent cyst bone grafting (13), cementing (6) or both (8) at a mean 4.8 years. In the ST group, 14 patients underwent cyst bone grafting (6), cementing (4), or both (4) at a mean of 2.7 years. PRO data improved significantly for both the STAR and ST group in all questionnaires (p<0.05 for all). Conclusion: Mobile-bearing total ankle arthroplasty in this cohort had a higher rate of cyst formation greater than 10 mm (95/232 patients, 41%) when compared to a fixed-bearing TAA (24/147, 16.3%). Only 24/95 (25%) of STAR patients and 14/24 (58%) of ST patients required surgical intervention for cyst management. Patient reported outcomes after cyst surgery improved significantly when compared to pre-cyst management surgery and did not differ between MB and FB cohorts (p=0.424). Successful surgical management of large cyst surrounding either mobile-bearing or fixed-bearing total ankle systems can be expected based on the results of this study. [Table: see text]


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0042
Author(s):  
Hatem Salem-Saqer ◽  
Martin Raglan ◽  
Sunil Dhar

Category: Ankle; Ankle Arthritis Introduction/Purpose: Total ankle arthroplasty (TAA) is increasingly used for treatment of end stage arthritis of the ankle; improvements continue to evolve in implant design and instrumentation. We present our experience of the Infinity Total Ankle Arthroplasty (Wright Medical), a fixed bearing 4th generation implant with improved instrumentation Methods: This is a retrospective review of prospectively collected data. From October 2016 to July 2019, we identified 92 (52M/40F) who had the infinity Total Ankle Replacement. This review is of 70 patients with a minimum of 1 year follow up (33M,37F). The mean age was 67.5 years (33-87); 32 right side and 38 left no bilaterals. The indication for surgery was end stage Osteoarthritis in 52, post traumatic arthritis 12, inflammatory arthritis 4, conversion of fusion to TAR 2. The preoperative deformity was graded according to the COFAS classification. All patients had follow up at 6 weeks, 3,6 and 12 months and then annually, with MOXFQ questionnaire and weight bearing radiographs. Results: TAA was performed with the use of fluoroscopy. 77% (54/70) had concomitant procedures as listed in Table.5% (4/70) had complications consisting of, 1 DVT, 1 intra operative medial malleolus fracture, 1 EHL tendon laceration and 1 wound break down. There were no deep or superficial infections. Improvement in clinical outcome and PROMS data was noted on follow up. The MOXFQ for Pain improved from 72 pre-op to 25 at 1year (p<0.001). The outcome for Walking improved from 83 pre-op to 30 at one year (p<0.001). Radiological alignment was maintained asymptomatic posterior heterotopic ossification was noted in 23(16%) patients, lucent lines under the tibial implant were noted in 4 ankles and 1 fibula erosion. 2 TAA (3%) needed to be revised due to malpositioning. Conclusion: Our results show significant improvement in patient outcomes, a short recovery time and marked improvement in mobility post operatively with a very low complication rate, we had no deep infection to date. Two implants were revised which we attribute to the learning curve at the start of practice. This implant is fluoroscopically navigated allowing precise implantation with dedicated instrumentation and we feel this attributed to the low complication rate and good results in our short-term study [Table: see text]


2018 ◽  
Vol 3 (2) ◽  
pp. 2473011418S0001
Author(s):  
Benjamin Hendy ◽  
Steven Raikin ◽  
David Pedowitz ◽  
Rachel Shakked ◽  
Ryan Rogero ◽  
...  

Category: Ankle, Ankle Arthritis Introduction/Purpose: Reports of ankle range of motion and how it affects patient outcomes following total ankle arthroplasty (TAA) have been mixed. Furthermore, recent studies have relied on clinical exam to obtain postoperative range of motion and have lacked preoperative functional scores. The purpose of our study was to analyze how preoperative range of motion and functional scores change with time following TAA using postoperative functional scores and radiographs for range of motion calculations. Methods: A retrospective chart review was performed on 107 patients (109 ankles) that had undergone fixed-bearing implant TAA by a single surgeon between 2010 and 2015. Preoperative range of motion was gathered clinically in office by the senior author. Postoperative range of motion through the ankle joint was evaluated with dedicated weight-bearing maximum dorsiflexion and plantarflexion lateral radiographs at 3 and 6 months, 1 and 2 years. The range of motion was measured using the angle measurement tool on the picture archiving and communication system. Patients completed visual analogue scale (VAS) for pain and the Foot and Ankle Ability Measure (FAAM) questionnaire subcategorized into activities of daily (ADL) and sports subscale preoperatively and at postoperative intervals of 3 and 6 months, 1 and 2 years. The mean age was 65 years (range, 31-83 years). Mean BMI was 28.1 (range, 14.9-44.9). There were 53 males (50%). Results: The mean total arc of ankle motion preoperatively was 20.7 degrees and improved significantly to 28.3, 34.3, 33.3, and 33.3 degrees at 3 and 6 months, 1 and 2 years, respectively (P<0.001) (Figure 1). Mean VAS pain and mean FAAM ADL preoperative scores improved significantly at each postoperative time point as seen in Figure 1 (P<0.001). Increased ankle range of motion was correlated with lower VAS preoperatively (r=-0.38, P=0.007), and at 1 year (r=-0.36, P<0.001), and 2 years (r=-0.2, P=0.033) postoperatively. Increased ankle range of motion was significantly correlated with higher FAAM-ADL at 3 months (r=0.48, P=0.012), 1 year (r=0.24, P<0.034), and 2 years (r=0.37, P<0.001) postoperatively. Conclusion: Patients undergoing fixed-bearing TAA had continued and sustained improvement from preoperative total arc of motion, pain, and function at each postoperative visit, up to 2 years. Ankle range of motion was noted to peak at 6 months, while pain and FAAM-ADL continued to improve up to 2 years postoperatively. Patients with greater ankle range of motion correlated with less pain and improved function at 1 and 2 years postoperatively. Though pain and function may continue to improve even as far out as 2 years postoperatively, it is not likely that range of motion will continue to increase.


2019 ◽  
Vol 40 (8) ◽  
pp. 880-887 ◽  
Author(s):  
Jeffrey E. Bischoff ◽  
Mehul A. Dharia ◽  
Justin S. Hertzler ◽  
Oliver N. Schipper

Background: Highly crosslinked polyethylene (HXLPE) was developed for its superior wear properties in comparison to conventional polyethylene (CPE). Concern over fatigue resistance has prevented widespread adoption of HXLPE for use in total ankle arthroplasty (TAA). The aim of this study was to determine whether HXLPE has sufficient fatigue strength for total ankle arthroplasty under simulated physiologically relevant motion profiles and loading in the ankle. Methods: Physiologic load and motion profiles representative of walking gait were incorporated into a computational model of a semiconstrained, fixed-bearing TAA to determine the loading state with highest stresses in the HXLPE bearing. Subsequent fatigue testing to 10 million cycles (Mc) at 5600 N was performed to assess bearing strength. Results: Peak stresses in the bearing were predicted at peak axial load and peak dorsiflexion during gait, occurring near heel off. All samples withstood 10 Mc of fatigue loading at that orientation without polyethylene bearing fracture. Conclusion: HXLPE had sufficient fatigue strength to withstand 10 Mc of loading at more than 5 times body weight at the point of peak stresses during simulated gait in total ankle arthroplasty. Clinical Relevance: HXLPE may be mechanically strong enough to withstand the in vivo demands of the ankle. Improvements in wear afforded by HXLPE can be obtained without compromising sufficient polyethylene strength properties in total ankle arthroplasty.


2014 ◽  
Vol 96 (23) ◽  
pp. 1983-1989 ◽  
Author(s):  
Samuel B. Adams ◽  
Constantine A. Demetracopoulos ◽  
Robin M. Queen ◽  
Mark E. Easley ◽  
James K. DeOrio ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document