ankle replacement
Recently Published Documents


TOTAL DOCUMENTS

837
(FIVE YEARS 233)

H-INDEX

55
(FIVE YEARS 6)

2022 ◽  
Vol 2022 ◽  
pp. 1-10
Author(s):  
Jian Yu ◽  
Dahang Zhao ◽  
Shuo Wang ◽  
Chao Zhang ◽  
Jiazhang Huang ◽  
...  

The implant design of the talar component for total ankle replacement (TAR) should match the surface morphology of the talus so that the replaced ankle can restore the natural motion of the tibiotalar joint and may reduce postoperative complications. The purpose of this study was to introduce a new 3D fitting method (the two-sphere fitting method of the talar trochlea with three fitting resection planes) to approximate the shape of the upper part of the talus for the Chinese population. 90 models of the tali from CT images of healthy volunteers were used in this study. Geometrical fitting and morphological measurements were performed for the surface morphology of the upper part of the talus. The accuracy of the two-sphere fitting method of the talar trochlea was assessed by a comparison of previously reported data. Parameters of the fitting geometries with different sizes were recorded and compared. Results showed that compared with previously reported one-sphere, cylinder, and bitruncated cone fitting methods, the two-sphere fitting method presented the smallest maximum distance difference, indicating that talar trochlea can be approximated well as two spheres. The radius of the medial fitting sphere R M was 20.69 ± 2.19  mm which was significantly smaller than the radius of the lateral fitting sphere R L of 21.32 ± 1.88  mm. After grouping all data by the average radius of fitting spheres, the result showed that different sizes of the upper part of the talus presented significantly different parameters except the orientation of the lateral cutting plane, indicating that the orientation of the lateral cutting plane may keep consistent for all upper part of the talus and have no relationship with the size. The linear regression analyses demonstrated a weak correlation ( R 2 < 0.5 ) between the majority of parameters and the average radius of the fitting spheres. Therefore, different sizes of the upper part of the talus presented unique morphological features, and the design of different sizes of talar components for TAR should consider the size-specific characteristics of the talus. The parameters measured in this study provided a further understanding of the talus and can guide the design of different sizes of the talar components of the TAR implant.


The Foot ◽  
2021 ◽  
Vol 49 ◽  
pp. 101830
Author(s):  
Zach J. Place ◽  
Deborah J. Macdonald ◽  
Nicholas D. Clement ◽  
Hisham Shalaby ◽  
John C. McKinley

2021 ◽  
pp. 107110072110538
Author(s):  
Georg Hauer ◽  
Reinhard Hofer ◽  
Markus Kessler ◽  
Jan Lewis ◽  
Lukas Leitner ◽  
...  

Background: The aim of this study was to assess the outcome of total ankle replacement (TAR) regarding revision rates by comparing clinical studies of the last decade to data displayed in arthroplasty registers. The secondary aim was to evaluate whether dependent clinical studies show a superior outcome to independent publications. Additionally, revision rates of mobile bearing implants (MB-TARs) were compared to those of fixed bearing implants (FB-TARs). Methods: Clinical studies on TARs between 2010 and 2020 were systematically reviewed, with the endpoint being a revision for any reason. The parameter “revision rate per 100 observed component years (CYs)” was calculated for each publication. The pooled revision rate for clinical studies was compared to the data reported in arthroplasty registers. In a second step, revision rates were subdivided and analyzed for independent and dependent publications and for FB-TARs and MB-TARs. Results: A total of 43 publications met the inclusion criteria comprising 5806 TARs. A revision rate of 1.8 per 100 observed CYs was calculated, corresponding to a 7-year revision rate of 12.6%. The 3 arthroplasty registers included showed revision rates ranging from 8.2% to 12.3% after 7 years. No significant difference between dependent and independent publications nor between FB-TARs and MB-TARs was detected. Conclusion: Revision rates of clinical studies and arthroplasty registers are comparable. Surgeons can compare their own revision rates with those from this study. Dependent studies do not seem to be biased, and no superiority for one bearing type can be described. Level of Evidence: Level III, systematic review of level III studies


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Andrew Dodd ◽  
Ellie Pinsker ◽  
Alastair S.E. Younger ◽  
Murray J. Penner ◽  
Kevin J. Wing ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document