Efficacy of clinical gait analysis: A systematic review

2011 ◽  
Vol 34 (2) ◽  
pp. 149-153 ◽  
Author(s):  
Tishya A.L. Wren ◽  
George E. Gorton ◽  
Sylvia Õunpuu ◽  
Carole A. Tucker
2017 ◽  
Vol 78 (5-6) ◽  
pp. 272-286 ◽  
Author(s):  
Magaly Lecat ◽  
Pierre Decavel ◽  
Eloi Magnin ◽  
Brigitte Lucas ◽  
Vincent  Gremeaux ◽  
...  

2017 ◽  
Vol 60 ◽  
pp. e86
Author(s):  
Yoshimasa Sagawa ◽  
Magaly Lecat ◽  
Eloi Magnin ◽  
Brigitte Lucas ◽  
Vincent Gremeaux ◽  
...  

2004 ◽  
Vol 37 (1) ◽  
pp. 27-32 ◽  
Author(s):  
M. B. van Iersel ◽  
W. Hoefsloot ◽  
M. Munneke ◽  
B. R. Bloem ◽  
M G M. Olde Rikkert

2017 ◽  
Vol 16 (1) ◽  
Author(s):  
Valentina Camomilla ◽  
Andrea Cereatti ◽  
Andrea Giovanni Cutti ◽  
Silvia Fantozzi ◽  
Rita Stagni ◽  
...  

2021 ◽  
Vol 85 ◽  
pp. 55-64
Author(s):  
Julian Rudisch ◽  
Thomas Jöllenbeck ◽  
Lutz Vogt ◽  
Thomas Cordes ◽  
Thomas Jürgen Klotzbier ◽  
...  

2020 ◽  
Vol 81 ◽  
pp. 281-282
Author(s):  
S. Pitarch-Corresa ◽  
C. Herrera-Ligero ◽  
J.Y. Torres-Villanueva ◽  
E. Medina-Ripoll ◽  
F. Parra-González ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2727
Author(s):  
Hari Prasanth ◽  
Miroslav Caban ◽  
Urs Keller ◽  
Grégoire Courtine ◽  
Auke Ijspeert ◽  
...  

Gait analysis has traditionally been carried out in a laboratory environment using expensive equipment, but, recently, reliable, affordable, and wearable sensors have enabled integration into clinical applications as well as use during activities of daily living. Real-time gait analysis is key to the development of gait rehabilitation techniques and assistive devices such as neuroprostheses. This article presents a systematic review of wearable sensors and techniques used in real-time gait analysis, and their application to pathological gait. From four major scientific databases, we identified 1262 articles of which 113 were analyzed in full-text. We found that heel strike and toe off are the most sought-after gait events. Inertial measurement units (IMU) are the most widely used wearable sensors and the shank and foot are the preferred placements. Insole pressure sensors are the most common sensors for ground-truth validation for IMU-based gait detection. Rule-based techniques relying on threshold or peak detection are the most widely used gait detection method. The heterogeneity of evaluation criteria prevented quantitative performance comparison of all methods. Although most studies predicted that the proposed methods would work on pathological gait, less than one third were validated on such data. Clinical applications of gait detection algorithms were considered, and we recommend a combination of IMU and rule-based methods as an optimal solution.


Sign in / Sign up

Export Citation Format

Share Document