Su1588 Performance Characteristics and Lack of Factors Affecting Diagnostic Yield of Single Operator PerOral Cholangioscopy for Indeterminate Biliary Strictures

2015 ◽  
Vol 81 (5) ◽  
pp. AB341
Author(s):  
Aaron J. Small ◽  
Gregory Lutzak ◽  
Seng-Ian Gan ◽  
Shayan Irani ◽  
Michael Gluck ◽  
...  
Endoscopy ◽  
2019 ◽  
Vol 52 (02) ◽  
pp. 107-114 ◽  
Author(s):  
Adriaan B. de Vries ◽  
Frans van der Heide ◽  
Rinze W. F. ter Steege ◽  
Jan Jacob Koornstra ◽  
Karel T. Buddingh ◽  
...  

Abstract Background Single-operator peroral cholangioscopy (sPOCS) is considered a valuable diagnostic modality for indeterminate biliary strictures. Nevertheless, studies show large variation in its characteristics and measures of diagnostic accuracy. Our aim was to estimate the diagnostic accuracy of sPOCS visual assessment and targeted biopsies for indeterminate biliary strictures. Additional aims were: estimation of the clinical impact of sPOCS and comparison of diagnostic accuracy with brush cytology. Methods A retrospective single-center study of adult patients who underwent sPOCS for indeterminate biliary strictures was performed. Diagnostic accuracy was defined as sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The clinical impact of sPOCS was assessed by review of medical records, and classified according to its influence on patient management. Results 80 patients were included, with 40 % having primary sclerosing cholangitis (PSC). Prior ERCP was performed in 88 %, with removal of a biliary stent prior to sPOCS in 55 %. The sensitivity, specificity, PPV, and NPV for sPOCS visual impression and targeted biopsies were 64 %, 62 %, 41 %, and 84 %, and 15 %, 65 %, 75 %, and 69 %, respectively. The clinical impact of sPOCS was limited; outcome changed management in 17 % of patients. Sequential brush cytology sensitivity, specificity, PPV, and NPV were 47 %, 95 %, 80 %, and 83 %. Conclusions The diagnostic accuracy of sPOCS for indeterminate biliary strictures was found to be inferior to brush cytology, with a low impact on patient management. These findings are obtained from a select patient population with a high prevalence of PSC and plastic stents in situ prior to sPOCS.


2012 ◽  
Vol 75 (4) ◽  
pp. AB387
Author(s):  
Raffaele Manta ◽  
Emanuele Dabizzi ◽  
Helga Bertani ◽  
Mauro Manno ◽  
Vincenzo G. Mirante ◽  
...  

2016 ◽  
Vol 84 (4) ◽  
pp. 681-687 ◽  
Author(s):  
Shyam Varadarajulu ◽  
Ji Young Bang ◽  
Muhammad K. Hasan ◽  
Udayakumar Navaneethan ◽  
Robert Hawes ◽  
...  

2016 ◽  
Vol 60 (2) ◽  
pp. 167-172 ◽  
Author(s):  
Shafqat Mehmood ◽  
Asif Loya ◽  
Muhammed Aasim Yusuf

Purpose: To evaluate the diagnostic yield of biliary brush cytology and the factors affecting positive results in patients with biliary strictures. Patients and Methods: The medical records of all patients who underwent endoscopic retrograde cholangiopancreatography (ERCP) with biliary brush cytology at our institution from November 2004 to December 2013 were reviewed in this retrospective study. The yield of positive brush cytology and the factors affecting positive yield, such as stricture location, age, gender and preprocedure CA 19.9 level were assessed. The final histopathology, diagnosis obtained by other methods, such as endoscopic ultrasound-guided fine-needle aspiration cytology, CT scan, Tru-Cut biopsy and/or clinical/radiological follow-up were used to identify true- and false-positive/negative results. The brush cytology results were divided into 4 main categories: malignant, benign, atypical cells and inadequate. Results: A total of 1,168 patients underwent ERCP during this 9-year period. Out of these, 142 patients had ERCP and biliary brushings for diagnosis. The mean age of the patients at presentation was 58.7 years (range 23-84 years; 64.8% males). The indication for referral was obstructive jaundice in all patients. Of the 142 patients, 77 (54.2%) had a distal common bile duct (CBD) stricture and 65 (45.8%) had a proximal /complex hilar stricture. The strictures were classified as proximal or distal, based on their relationship with the cystic duct; those below the cystic duct insertion were classified as distal and those above it were considered proximal. The diagnostic yield of brush cytology was 58.5%. The diagnostic yield was higher for proximal than for distal CBD strictures (67 vs. 50%; p = 0.047). It was also higher for females (58 vs. 57.6%; p = 0.94), patients >50 years (60 vs. 50%; p = 0.29) and those with a CA 19.9 level >300 IU/ml (59.4 vs. 55.5%; p = 0.65) but did not reach statistical significance for any of these parameters. Complete follow-up data were available for 96 patients and 46 patients were lost to follow-up. The sensitivity, specificity, positive predictive value and negative predictive value were 65.3, 100, 100 and 27%, respectively. When patients with atypia were included in the group with positive results, the diagnostic yield increased to 65.5% with a diagnostic sensitivity of 68.6%. There were 27 false-negative diagnoses, 10 patients were true-negative and no patients had a false-positive diagnosis. Conclusion: Biliary brush cytology is a safe and simple initial diagnostic procedure in patients with biliary strictures and can be performed at the time of therapeutic ERCP. If performed correctly and then interpreted by a dedicated cytopathologist, it has a good diagnostic yield and sensitivity. We feel that the low rates of success with this technique reported in some earlier studies have led to a feeling that this is not a particularly useful technique. We recommend that this topic should be revisited, and that the technique should be used more often.


Endoscopy ◽  
2018 ◽  
Vol 51 (01) ◽  
pp. 50-59 ◽  
Author(s):  
Yun Lee ◽  
Jong Moon ◽  
Hyun Choi ◽  
Hee Kim ◽  
Hyun Lee ◽  
...  

Abstract Background Although endoscopic retrograde cholangiopancreatography (ERCP) is a first-line diagnostic modality for suspected malignant biliary stricture (MBS), the diagnostic yield of ERCP-based tissue sampling is insufficient. Peroral cholangioscopy-guided forceps biopsy (POC-FB) and endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) are evolving as reliable diagnostic procedures for inconclusive MBS. This study aimed to evaluate the usefulness of a diagnostic approach using POC-FB or EUS-FNAB according to the stricture location in patients with suspected MBS. Methods Consecutive patients diagnosed with suspected MBS with obstructive jaundice and/or cholangitis were enrolled prospectively. ERCP with transpapillary forceps biopsy (TPB) was performed initially. When malignancy was not confirmed by TPB, POC-FB using a SpyGlass direct visualization system or direct POC using an ultraslim endoscope was performed for proximal strictures, and EUS-FNAB was performed for distal strictures as a follow-up biopsy. Results Among a total of 181 patients, initial TPB showed malignancy in 122 patients, and the diagnostic accuracy of initial TPB was 71.8 % (95 % confidence interval [CI] 65.3 % – 78.4 %]. Of the 59 patients in whom TPB was negative for malignancy, 32 had proximal biliary strictures and underwent successful POC. The remaining 27 patients had distal strictures and underwent successful EUS-FNAB. The accuracy of malignancy detection using POC-FB for proximal biliary strictures and EUS-FNAB for distal biliary strictures was 93.6 % (95 %CI 84.9 %−100 %) and 96.3 % (95 %CI 89.2 %−100 %), respectively. The overall diagnostic accuracy for the combination of TPB with either POC-FB for proximal strictures and EUS-FNAB for distal strictures was 98.3 % (95 %CI 95.9 %−100 %) and 98.4 % (95 %CI 95.3 %−100 %), respectively. Conclusions An approach using POC-FB or EUS-FNAB according to the stricture location may be useful in the diagnosis of suspected MBS.


Sign in / Sign up

Export Citation Format

Share Document