scholarly journals Limited diagnostic accuracy and clinical impact of single-operator peroral cholangioscopy for indeterminate biliary strictures

Endoscopy ◽  
2019 ◽  
Vol 52 (02) ◽  
pp. 107-114 ◽  
Author(s):  
Adriaan B. de Vries ◽  
Frans van der Heide ◽  
Rinze W. F. ter Steege ◽  
Jan Jacob Koornstra ◽  
Karel T. Buddingh ◽  
...  

Abstract Background Single-operator peroral cholangioscopy (sPOCS) is considered a valuable diagnostic modality for indeterminate biliary strictures. Nevertheless, studies show large variation in its characteristics and measures of diagnostic accuracy. Our aim was to estimate the diagnostic accuracy of sPOCS visual assessment and targeted biopsies for indeterminate biliary strictures. Additional aims were: estimation of the clinical impact of sPOCS and comparison of diagnostic accuracy with brush cytology. Methods A retrospective single-center study of adult patients who underwent sPOCS for indeterminate biliary strictures was performed. Diagnostic accuracy was defined as sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The clinical impact of sPOCS was assessed by review of medical records, and classified according to its influence on patient management. Results 80 patients were included, with 40 % having primary sclerosing cholangitis (PSC). Prior ERCP was performed in 88 %, with removal of a biliary stent prior to sPOCS in 55 %. The sensitivity, specificity, PPV, and NPV for sPOCS visual impression and targeted biopsies were 64 %, 62 %, 41 %, and 84 %, and 15 %, 65 %, 75 %, and 69 %, respectively. The clinical impact of sPOCS was limited; outcome changed management in 17 % of patients. Sequential brush cytology sensitivity, specificity, PPV, and NPV were 47 %, 95 %, 80 %, and 83 %. Conclusions The diagnostic accuracy of sPOCS for indeterminate biliary strictures was found to be inferior to brush cytology, with a low impact on patient management. These findings are obtained from a select patient population with a high prevalence of PSC and plastic stents in situ prior to sPOCS.

2019 ◽  
Vol 12 ◽  
pp. 263177451985316 ◽  
Author(s):  
Stephanie Yan ◽  
Sooraj Tejaswi

Aims: Endoscopic management of indeterminate strictures and complex stones remains a challenge, for which the latest generation single-operator digital cholangioscope (SpyGlass DS) has shown promising results. We aimed to study the clinical impact of single-operator digital cholangioscope at our tertiary academic center. Methods: We retrospectively reviewed all digital cholangioscopies performed from June 2015 to May 2018. Patient characteristics, procedure characteristics, and post-procedural patient outcomes were recorded. Results: A total of 50 patients (26 men, average age 61.4 years) underwent 67 procedures. Indications were biliary stones (21/50, 42%), strictures and primary sclerosing cholangitis surveillance (22/50, 46%), and miscellaneous (7/50, 14%). The average procedure time was 82 ± 29 min (99.5 min for stones and 74.2 min for strictures). Stone clearance was achieved in 19/21 (90.47%) cases, with electrohydraulic lithotripsy employed in 16/21 and repeat cholangioscopy necessary in 9/21. Malignant strictures (10) were differentiated from benign (12) in all cases both in patients with primary sclerosing cholangitis (9) and in those without (13), based on visual cholangioscopic features (sensitivity and specificity 100%), single-operator digital cholangioscope–directed biopsies (sensitivity 60% and specificity 100%), and brush cytology (sensitivity 37.5% and specificity 100%). Complications included one post-sphincterotomy bleeding and one post-procedural cholangitis despite antibiotic prophylaxis, but no procedure-related mortality. Conclusion: Single-operator digital cholangioscope had a high success rate and a low rate of complications for management of indeterminate strictures and difficult biliary stones. Visual cholangioscopic features of biliary strictures had excellent diagnostic accuracy, and targeted biopsies outperformed brush cytology. Early implementation of cholangioscopy for select indications leads to successful patient outcomes and reduces diagnostic delays, cost, and risks of repeat endoscopic retrograde cholangiopancreatographies.


Digestion ◽  
2021 ◽  
pp. 1-7
Author(s):  
Kilian Weigand ◽  
Merlin Küchle ◽  
Ina Zuber-Jerger ◽  
Martina Müller ◽  
Arne Kandulski

Background/Aims: Digital single-operator cholangioscopy (dSOC) has revolutionized bile duct visualization. Interventions like electrohydraulic or laser lithotripsy, inspection of suspicious areas, and targeted biopsies have become possible quick and easy. One main indication for dSOC remains the evaluation of indeterminate biliary strictures. Objective and Methods: We analyzed 180 consecutive dSOCs procedures performed in a high-volume tertiary center to evaluate sensitivity, specificity as well as positive and negative predictive values (PPV and NPV) for indeterminate strictures. Furthermore, technical success and complications were analyzed. Results: In 92–97%, the region of interest was reached and successfully visualized. In 83–100%, targeted biopsies were obtained from the suspicious area. Only the distal bile duct was less successful with only 84 and 62%, respectively. In general, dSOC procedures were safe. Cholangitis was the main complication. Regarding the diagnostic accuracy of dSOC of indeterminate biliary strictures, we found a sensitivity of 0.87 and specificity of 0.88, over all. Within the whole cohort, the investigators’ assessment directly after dSOC had a PPV of 0.63 and a NPV of 0.97. In patients with biliary lesions or stenosis suspicious for malignancy, the dSOC-based visual diagnosis revealed a very high diagnostic accuracy with sensitivity and specificity of 1.0 (95% CI 0.86–1.0) and 0.76 (95% CI 0.56–0.9) with a PPV of 0.77 (95% CI 0.59–0.9) and a high NPV of 1.0 (95% CI 0.85–1.0). Conclusions: Our study demonstrates that dSOC has a high diagnostic accuracy as well as a favorable safety profile. Therefore, dSOC should be discussed as standard of care during endoscopic retrograde cholangiography for indeterminate biliary lesions.


2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
pp. 8-13
Author(s):  
Pankaj Kumar Singh ◽  
Budhaditya Sanyal ◽  
Mohit Bhatnagar ◽  
Mandeep Joshi ◽  
Shreya Verma

Aims and objectives: This study aims to assess the diagnostic accuracy and timeliness of ultrasonography by static method only for identication of Endotracheal tube (ET Tube) placement in the trachea in emergency settings vs existing clinical methods. Material and Methods: This prospective study was carried out in the emergency room from October 2018 till the end of March 2019. The ultrasonography was performed in 120 emergency patients only after the intubation had been completed ie, static phase. A linear probe was used over the neck to identify the predened signs of ET intubation. Residents who perform ultrasound examination ll a form after assessment of each patient. Results: It was found that Tracheal Intubation-USG Sensitivity was 99.1, Specicity was 91.7, Positive Predictive Value: 99.1, Negative Predictive Value was 91.7 and Accuracy was 98.3%. Ultrasonography can be used as an adjunct tool to verify the ETTposition by Emergency Physicians which can be performed easily after a brieng or short-course training.Conclusion:This study demonstrates that US imaging has a high diagnostic accuracy to immediately conrm proper ETT placement post-intubation in an emergency setup. Therefore, it seems that ultrasonography using a static technique only is a proper screening tool in determining endotracheal tube placement.


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


2012 ◽  
Vol 20 (01) ◽  
pp. 132-138
Author(s):  
MUHAMMAD ATIF ◽  
MUHAMMAD ABDULLAH ◽  
MUHAMMAD JAVAD YOUSAF ◽  
Khalid Buland

Objective: To compare the accuracy of Upper lip bite test with modified Mallampati classification for predicting the difficultlaryngoscopic intubation. Study Design: Cross sectional Study. Place and duration of study: The study was carried out at Department ofAnaesthesiology, Intensive Care and Pain management, Combined Military hospital, Rawalpindi from September 2008 to August 2009.Patients and Methods: Four hundred patients undergoing elective surgery meeting the inclusion/exclusion criteria were enrolled afterwritten informed consent. The airways of the patients were evaluated by using the modified Mallampati classification (MMP) and theUpper lip bite test (ULBT). MMP class 3 or 4 and ULBT class 3 were considered as indicators of difficult intubation. The laryngeal view wasgraded by Cormack and Lehane classification (Gold standard). Grade 1 or 2 was considered to represent easy intubation and grade 3 or 4to represent difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy werecalculated for both the tests separately by using the 2×2 table. Results: ULBT had a higher accuracy of 94%, specificity of 99.2% andpositive predictive value 70% compared to MMP accuracy of 82.7%, specificity of 84.4% and positive predictive value of 22.7%.Conclusions: The diagnostic accuracy of the Upper lip bite test was more than the modified Mallampati classification. We suggest that itbe compared with the other prevailing tests as well which are often used to assess difficult intubations.


2017 ◽  
Vol 19 (6) ◽  
pp. 720-728 ◽  
Author(s):  
Gloria J. Guzmán Pérez-Carrillo ◽  
Christopher Owen ◽  
Katherine E. Schwetye ◽  
Spencer McFarlane ◽  
Ananth K. Vellimana ◽  
...  

OBJECTIVEMany patients with medically intractable epilepsy have mesial temporal sclerosis (MTS), which significantly affects their quality of life. The surgical excision of MTS lesions can result in marked improvement or even complete resolution of the epileptic episodes. Reliable radiological diagnosis of MTS is a clinical challenge. The purpose of this study was to evaluate the utility of volumetric mapping of the hippocampi for the identification of MTS in a case-controlled series of pediatric patients who underwent resection for medically refractory epilepsy, using pathology as a gold standard.METHODSA cohort of 57 pediatric patients who underwent resection for medically intractable epilepsy between 2005 and 2015 was evaluated. On pathological investigation, this group included 24 patients with MTS and 33 patients with non-MTS findings. Retrospective quantitative volumetric measurements of the hippocampi were acquired for 37 of these 57 patients. Two neuroradiologists with more than 10 years of experience who were blinded to the patients' MTS status performed the retrospective review of MR images. To produce the volumetric data, MR scans were parcellated and segmented using the FreeSurfer software suite. Hippocampal regions of interest were compared against an age-weighted local regression curve generated with data from the pediatric normal cohort. Standard deviations and percentiles of specific subjects were calculated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined for the original clinical read and the expert readers. Receiver operating characteristic curves were generated for the methods of classification to compare results from the readers with the authors' results, and an optimal threshold was determined. From that threshold the sensitivity, specificity, PPV, and NPV were calculated for the volumetric analysis.RESULTSWith the use of quantitative volumetry, a sensitivity of 72%, a specificity of 95%, a PPV of 93%, an NPV of 78%, and an area under the curve of 0.84 were obtained using a percentage difference of normalized hippocampal volume. The resulting specificity (95%) and PPV (93%) are superior to the original clinical read and to Reader A and Reader B's findings (range for specificity 74%–86% and for PPV 64%–71%). The sensitivity (72%) and NPV (78%) are comparable to Reader A's findings (73% and 81%, respectively) and are better than those of the original clinical read and of Reader B (sensitivity 45% and 63% and NPV 71% and 70%, respectively).CONCLUSIONSVolumetric measurement of the hippocampi outperforms expert readers in specificity and PPV, and it demonstrates comparable to superior sensitivity and NPV. Volumetric measurements can complement anatomical imaging for the identification of MTS, much like a computer-aided detection tool would. The implementation of this approach in the daily clinical workflow could significantly improve diagnostic accuracy.


Sign in / Sign up

Export Citation Format

Share Document