Percutaneous recanalization of superior vena cava occlusions for cardiac implantable electronic device implantation: Tools and techniques

Heart Rhythm ◽  
2020 ◽  
Vol 17 (11) ◽  
pp. 2010-2015 ◽  
Author(s):  
Naga Venkata K. Pothineni ◽  
C. Anwar A. Chahal ◽  
David S. Frankel ◽  
Fermin C. Garcia ◽  
Jay Giri ◽  
...  
2016 ◽  
Vol 57 (2) ◽  
pp. 101-106 ◽  
Author(s):  
Roman Steckiewicz ◽  
Dariusz A. Kosior ◽  
Marek Rosiak ◽  
Elżbieta Świętoń ◽  
Przemysław Stolarz ◽  
...  

1989 ◽  
Vol 9 (1) ◽  
pp. 91-94 ◽  
Author(s):  
Thomas Meinertz ◽  
Wolfgang Kasper ◽  
Sabine Löhr-Schwaab ◽  
Hans Jürgen Brambs ◽  
Wolfgang Gerok ◽  
...  

PLoS ONE ◽  
2021 ◽  
Vol 16 (5) ◽  
pp. e0251829
Author(s):  
Sameer Al-Maisary ◽  
Gabriele Romano ◽  
Matthias Karck ◽  
Raffaele De Simone ◽  
Jamila Kremer

Background The implantation of cardiac implantable electronic devices (CIED) has increased in the last decades with improvement in the quality of life of patients with cardiac rhythm disorders. The presence of bilateral subclavian, innominate or superior vena cava obstruction is a major limitation to device revision and/or upgrade. Methods and material This is retrospective study of patients who underwent laser-assisted lead extraction (LLE) (GlideLight laser sheath, Spectranetics Corporation, Colorado Springs, USA) with lead revision or upgrade using the laser sheath as a guide rail. Patients with known occlusion, severe stenosis or functional obstruction of the venous access vessels with indwelling leads were included in this study. Results 106 patients underwent percutaneous LLE with lead revision and/or upgrade. Preoperative known complete occlusion or severe stenosis of access veins was present in 23 patients (21.5%). More patients with implantable cardioverter-defibrillator (ICD) underwent LLE (64.1%) than patients with CRT-Ds (24.5%) and pacemaker patients (11.3%). In total 172 leads were extracted: 79 (45.9%) single-coil defibrillator leads, 35 (20.3%) dual-coil defibrillator leads, 31 (18.0%) right atrial leads, 24 (13.9%) right ventricular leads and three (1.7%) malfunctional coronary sinus left ventricular pacing leads. The mean age of leads was 99.2±65.6 months. The implantation of new leads after crossing the venous stenosis/obstruction was successful in 98 (92.4%) cases. Postoperative complications were pocket hematoma in two cases and wound infection in one case. No peri-operative and no immediate postoperative death was recorded. One intraoperative superior vena cava tear was treated by immediate thoracotomy and surgical repair. Conclusion In a single-center study on LLE in the presence of supra-cardiac occlusion of the central veins for CIED lead upgrade and revision we could demonstrate a low procedural complication rate with no procedural deaths. Most of the leads could be completely extracted to revise or upgrade the system. Our study showed a low complication rate, with acceptable mortality rates.


2020 ◽  
Vol 30 (8) ◽  
pp. 1186-1187
Author(s):  
Ali Hakan Konuş ◽  
Muhammet Raşit Sayın ◽  
Ahmet Vural

AbstractPersistent left superior vena cava is a thoracic venous return anomaly. Tetralogy of Fallot is one of the most common congenital anomalies seen with persistent left superior vena cava. We are presenting a successful cardiac resynchronisation therapy device implantation in a patient with repaired tetralogy of Fallot and persistent left superior vena cava combination which has not been previously reported in the literature.


2005 ◽  
Vol 65 (1) ◽  
pp. 54-59 ◽  
Author(s):  
Islam Bolad ◽  
Sree Karanam ◽  
Dilip Mathew ◽  
Roy John ◽  
Thomas Piemonte ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document