Cooling characteristics of the trailing-edge slot downstream from internal multi-ribbed channel

Author(s):  
Lin Ye ◽  
Cunliang Liu ◽  
Andong Zhu ◽  
Fan Zhang ◽  
Changxian Zhang
Keyword(s):  
Author(s):  
Suhyun Kim ◽  
Seungwon Suh ◽  
Seungchan Baek ◽  
Wontae Hwang

Abstract Convective cooling in a gas turbine blade internal trailing edge channel is often insufficient at the sharp trailing edge. This study examines convective heat transfer and pressure drop within a simplified trailing edge channel. The internal passage has been modeled as a right triangular channel with a 9° angle sharp corner. Smooth baseline and ribbed copper plates were heated from underneath via a uniform heat flux heater and examined via infrared thermography. Non-uniformity in the heat flux due to conduction is corrected by a RANS conjugate heat transfer calculation, which was validated by the mean velocity, friction factor, and temperature fields from experiments and LES simulations. Nusselt number distributions illustrate that surface heat transfer is increased considerably with ribs, and coupled with the vortices in the flow. Heat transfer at the sharp corner is increased by more than twofold due to ribs placed at the center of the channel, due to secondary flow. The present partially ribbed channel utilizes secondary flow toward the corner, and is presumed to have better thermal performance than a fully ribbed channel. Thus, it is important to set the appropriate rib length within the channel.


2012 ◽  
Vol 135 (1) ◽  
Author(s):  
Waseem Siddique ◽  
Lamyaa El-Gabry ◽  
Igor V. Shevchuk ◽  
Torsten H. Fransson

High inlet temperatures in a gas turbine lead to an increase in the thermal efficiency of the gas turbine. This results in the requirement of cooling of gas turbine blades/vanes. Internal cooling of the gas turbine blade/vanes with the help of two-pass channels is one of the effective methods to reduce the metal temperatures. In particular, the trailing edge of a turbine vane is a critical area, where effective cooling is required. The trailing edge can be modeled as a trapezoidal channel. This paper describes the numerical validation of the heat transfer and pressure drop in a trapezoidal channel with and without orthogonal ribs at the bottom surface. A new concept of ribbed trailing edge has been introduced in this paper which presents a numerical study of several trailing edge cooling configurations based on the placement of ribs at different walls. The baseline geometries are two-pass trapezoidal channels with and without orthogonal ribs at the bottom surface of the channel. Ribs induce secondary flow which results in enhancement of heat transfer; therefore, for enhancement of heat transfer at the trailing edge, ribs are placed at the trailing edge surface in three different configurations: first without ribs at the bottom surface, then ribs at the trailing edge surface in-line with the ribs at the bottom surface, and finally staggered ribs. Heat transfer and pressure drop is calculated at Reynolds number equal to 9400 for all configurations. Different turbulent models are used for the validation of the numerical results. For the smooth channel low-Re k-ɛ model, realizable k-ɛ model, the RNG k-ω model, low-Re k-ω model, and SST k-ω models are compared, whereas for ribbed channel, low-Re k-ɛ model and SST k-ω models are compared. The results show that the low-Re k-ɛ model, which predicts the heat transfer in outlet pass of the smooth channels with difference of +7%, underpredicts the heat transfer by −17% in case of ribbed channel compared to experimental data. Using the same turbulence model shows that the height of ribs used in the study is not suitable for inducing secondary flow. Also, the orthogonal rib does not strengthen the secondary flow rotational momentum. The comparison between the new designs for trailing edge shows that if pressure drop is acceptable, staggered arrangement is suitable for the outlet pass heat transfer. For the trailing edge wall, the thermal performance for the ribbed trailing edge only was found about 8% better than other configurations.


Author(s):  
Waseem Siddique ◽  
Igor V. Shevchuk ◽  
Lamyaa A. El-Gabry ◽  
Torsten H. Fransson

High inlet temperatures in a gas turbine lead to an increase in the thermal efficiency of the gas turbine. This results in the requirement of cooling of gas turbine blades/vanes. Internal cooling of the gas turbine blade/vanes with the help of two-pass channels is one of the effective methods to reduce the metal temperatures. Especially the trailing edge of a turbine vane is a critical area, where effective cooling is required. The trailing edge can be modeled as a trapezoidal channel. This paper describes the numerical validation of the heat transfer and pressure drop in a trapezoidal channel with and without orthogonal ribs at the bottom surface. A new concept of ribbed trailing edge has been introduced in this paper which presents a numerical study of several trailing edge cooling configurations based on the placement of ribs at different walls. The baseline geometries are two-pass trapezoidal channels with and without orthogonal ribs at the bottom surface of the channel. Ribs induce secondary flow which results in enhancement of heat transfer therefore for enhancement of heat transfer at the trailing edge, ribs are placed at the trailing edge surface in three different configurations: first without ribs at the bottom surface, then ribs at trailing edge surface in-line with the ribs at bottom surface and finally staggered ribs. Heat transfer and pressure drop is calculated at Reynolds number equal to 9400 for all configurations. Different turbulent models are used for the validation of the numerical results. For the smooth channel low-Re k-ε model, realizable k-ε model, the RNG k-ω model, low-Re k-ω model and SST k-ω models are compared, whereas for ribbed channel low-Re k-ε model and SST k-ω models are compared. The results show that the low-Re k-ε model, which predicts the heat transfer in outlet pass of the smooth channels with difference of +7%, underpredicts the heat transfer by −17% in case of ribbed channel compared to experimental data. Using the same turbulence model shows that the height of ribs used in the study is not suitable for inducing secondary flow. Also, the orthogonal rib does not strengthen the secondary flow rotational momentum. The comparison between the new designs for trailing edge shows that if pressure drop is acceptable, staggered arrangement is suitable for the outlet pass heat transfer. For the trailing edge wall, the thermal performance for ribbed trailing edge only, was found about 8% better than other configurations.


AIAA Journal ◽  
2002 ◽  
Vol 40 ◽  
pp. 2206-2216 ◽  
Author(s):  
A. Oberai ◽  
F. Roknaldin ◽  
T. J. R. Hughes

AIAA Journal ◽  
1997 ◽  
Vol 35 ◽  
pp. 1780-1782
Author(s):  
G. Ben-Dor ◽  
T. Elperin ◽  
H. Li ◽  
E. Vasiliev ◽  
A. Chpoun ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document