Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures

Injury ◽  
2020 ◽  
Vol 51 (4) ◽  
pp. 995-1003 ◽  
Author(s):  
Jiantao Li ◽  
Menglin Wang ◽  
Jianfeng Zhou ◽  
Hao Zhang ◽  
Lianting Li
2020 ◽  
Vol 21 (1) ◽  
Author(s):  
Shi Zhan ◽  
Dajun Jiang ◽  
Jian Xu ◽  
Ming Ling ◽  
Kai Yang ◽  
...  

Abstract Background The treatment of vertical femoral neck fractures (vFNFs) in young patients remains challenging, with a high complication rate by using traditional techniques. The use of cannulated screws (CSs) combined with a buttress plate represents an alternative approach for treating vFNFs. However, the biomechanical influence of the use or non-use of the proximal screws of buttress plates on vFNFs stability remains unclear. This study aims to analyse the biomechanics of buttress plate fixation with or without the use of proximal screws through finite element analysis (FEA) to further understand this approach. Methods We built five vFNFs (Pauwels angle 70°) finite element models treated using three cannulated screws (CS group) or three cannulated screws plus a locking buttress plate (buttress group). In the buttress group, use or non-use of proximal screws was carried out on two types of plates (4-hole & 6-hole). The following seven parameters were analysed to compare biomechanical properties of the five models: the stiffness; the maximal stress of the plate system (plate and screws), CSs and bone (MPS, MCS, MBS); the maximal displacement of internal fixations (plate system & CSs) and bone (MIFD, MBD); and the maximal relative displacement of interfragments (MID). Results Compared with CS model, the buttress models exhibited improved biomechanical properties, with increased stiffness and decreased MCS, MBS, MIFD, MBD and MID. The models fixed using buttress plates combined with a proximal screw showed greater stiffness (+ 3.75% & + 8.31% vs + 0.98% & + 4.57%) and MPS (795.6 & 947.2 MPa vs 294.9 & 556.2 MPa) values, and smaller MCS, MBS, MIFD, MBD and MID (− 3.41% to − 15.35% vs − 0.07% to − 4.32%) values than those using the same length plates without a proximal screw. Conclusions Based on the FEA results, buttress plates can improve construct mechanics, help to resist shear force and prevent varus collapse; under the modelling conditions, the use of a proximal screw on buttress plate may be a key technical feature in improving anti-shearing ability; additionally, this screw may be essential to reduce stress and prevent re-displacement of cannulated screws and fracture fragments.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Jiantao Li ◽  
Menglin Wang ◽  
Jianfeng Zhou ◽  
Lin Han ◽  
Hao Zhang ◽  
...  

Objectives. In the present study, we evaluated the mechanical outcome of different configurations of cannulated compression screws for the fixation of Pauwels type III femoral neck fracture and the stress distribution around the holes corresponding to fixation protocol after screws removal. Methods. The Pauwels type III of femoral neck fracture was created in 3-matic software and the models of cannulated compression screws were constructed using UG-NX software. Five fixation systems were assembled to the fracture models. Abaqus software was used to perform the process of finite element analysis. Values of stress distribution, maximum stress, model principal strains of proximal fragment, and stress distribution around the holes of femur model were recorded. Results. Stress of cannulated compression screws was intensely focused on the middle area of the screw near the fragment of each group. Inverted triangle model showed the highest peak stress on screws under different phases of load. Each screw dispersed some stresses, but at least one underwent the peak stress. Fracture model fixed by inverted triangle configuration showed the lowest volume of yielding strain in the proximal fragment. The area of higher stress around the holes was largest after triangle screws removal when compared with other four models. Conclusions. Our study indicated that different cannulated compression screws fixation configurations for the unstable femoral neck fractures showed the different mechanical efficiency. Inverted triangular configuration showed the mechanical advantage and being less likely to cutout. The fixation strategy of triangle configuration was least recommended if patients tended to remove the implants.


2021 ◽  
Vol 27 ◽  
Author(s):  
Hai Huang ◽  
Zhengkuan Feng ◽  
Weifei Wang ◽  
Cheng Yang ◽  
Jianwen Liao ◽  
...  

Injury ◽  
2019 ◽  
Vol 50 (11) ◽  
pp. 1895-1900
Author(s):  
Jia Li ◽  
Pengbin Yin ◽  
Licheng Zhang ◽  
Hua Chen ◽  
Peifu Tang

Sign in / Sign up

Export Citation Format

Share Document