Internet of things-assisted architecture for QRS complex detection in real time

2021 ◽  
pp. 100395
Author(s):  
Ricardo Rodríguez-Jorge ◽  
I. De León-Damas ◽  
Jiri Bila ◽  
Jiří Škvor
2017 ◽  
Vol 17 (08) ◽  
pp. 1750111 ◽  
Author(s):  
M. M. BENOSMAN ◽  
F. BEREKSI-REGUIG ◽  
E. GORAN SALERUD

Heart rate variability (HRV) analysis is used as a marker of autonomic nervous system activity which may be related to mental and/or physical activity. HRV features can be extracted by detecting QRS complexes from an electrocardiogram (ECG) signal. The difficulties in QRS complex detection are due to the artifacts and noises that may appear in the ECG signal when subjects are performing their daily life activities such as exercise, posture changes, climbing stairs, walking, running, etc. This study describes a strong computation method for real-time QRS complex detection. The detection is improved by the prediction of the position of [Formula: see text] waves by the estimation of the RR intervals lengths. The estimation is done by computing the intensity of the electromyogram noises that appear in the ECG signals and known here in this paper as ECG Trunk Muscles Signals Amplitude (ECG-TMSA). The heart rate (HR) and ECG-TMSA increases with the movement of the subject. We use this property to estimate the lengths of the RR intervals. The method was tested using famous databases, and also with signals acquired when an experiment with 17 subjects from our laboratory. The obtained results using ECG signals from the MIT-Noise Stress Test Database show a QRS complex detection error rate (ER) of 9.06%, a sensitivity of 95.18% and a positive prediction of 95.23%. This method was also tested against MIT-BIH Arrhythmia Database, the result are 99.68% of sensitivity and 99.89% of positive predictivity, with ER of 0.40%. When applied to the signals obtained from the 17 subjects, the algorithm gave an interesting result of 0.00025% as ER, 99.97% as sensitivity and 99.99% as positive predictivity.


2011 ◽  
Vol 27 (3) ◽  
pp. 222-230 ◽  
Author(s):  
Peng LI ◽  
Changchun LIU ◽  
Ming ZHANG ◽  
Wenbiao CHE ◽  
Jian LI

Author(s):  
Dorthe B. Saadi ◽  
George Tanev ◽  
Morten Flintrup ◽  
Armin Osmanagic ◽  
Kenneth Egstrup ◽  
...  

2017 ◽  
Vol 16 (1) ◽  
Author(s):  
Salah Hamdi ◽  
Asma Ben Abdallah ◽  
Mohamed Hedi Bedoui

Author(s):  
Fatima Yasmeen ◽  
Mohammad Arifuddin Mallick ◽  
Yusuf Uzzaman Khan

<p><span lang="EN-IN">This paper presents a novel method for QRS detection. To accomplish this task ECG signal was first filtered by using a third order Savitzky Golay filter. The filtered ECG signal was then preprocessed by a Wavelet based denoising in a real-time fashion to minimize the undefined noise level. R-peak was then detected from denoised signal after wavelet denoising. Windowing mechanism was also applied for finding any missing R-peaks. All the 48 records have been used to test the proposed method. During this testing, 99.97% sensitivity and 99.99% positive predictivity is obtained for QRS complex detection.</span></p>


Sign in / Sign up

Export Citation Format

Share Document