Astigmatism induced by intraocular lens tilt evaluated via ray tracing

2018 ◽  
Vol 44 (6) ◽  
pp. 745-749 ◽  
Author(s):  
Mitchell P. Weikert ◽  
Abhinav Golla ◽  
Li Wang
Author(s):  
I.L. Kulikova ◽  
◽  
N.S. Timofeyeva ◽  
D.B. Abramenko ◽  
◽  
...  

Purpose. Determination of the influence of the intraocular lens (IOL) inclination and decentration on the magnitude of induced astigmatism in a theoretical study using software on an eye model. Material and methods. An eye model with the specified parameters was performed to carry out the calculation. Modulation of the change in the wavefront was carried out using the Zemax program (LLC, USA). In the model eye, the probability of induction of astigmatism was analyzed depending on the change in the position of the aspherical IOL Acrysof IQ 16.0, 22.0 and 24.0 diopters and the toric model Acrysof IQ Toric SN6AT3, SN6AT4 and SN6AT5. The angle of inclination of the IOL relative to the horizontal plane was examined from 0° to 10° with a step of 1°, decentration from 0.1 to 1.5 mm with a step of 0.1 mm. At each IOL position, aberration data of the 2nd order Z (2, 2) were recorded. The obtained results were used to calculate the critical tilt angle and decentration. Results. The magnitude of induced astigmatism increased with the rise of the degree of inclination and decentration, corresponding to an increase in the optical power of the IOL. Accordingly, critically significant were the values of 3.0° inclination for the aspherical IOL with an optical power of 22.0 and 22.0 diopters and 3.5° for 16.0 diopters, decentration – 0.7 mm and 1.0 mm. The inclination of the TIOL relative to the horizontal plane revealed the induction of the magnitude of inverse astigmatism, according to an increase in the inclination angle of 0.3 diopters at a slope of 3–4°. Conclusions. The tilt and decentration of the aspherical and TIOL patterns induce astigmatism depending on the increase in IOL power. The inclination of the TIOL in relation to the horizontal plane set at 90 ° promotes the induction of astigmatism. Key words: astigmatism, toric intraocular lenses, tilt and decentration of the intraocular lens, ray tracing


2011 ◽  
Vol 151 (3) ◽  
pp. 406-412.e2 ◽  
Author(s):  
Dhivya Ashok Kumar ◽  
Amar Agarwal ◽  
Gaurav Prakash ◽  
Soosan Jacob ◽  
Yoga Saravanan ◽  
...  

2014 ◽  
Vol 58 (3) ◽  
pp. 276-281 ◽  
Author(s):  
Megumi Saiki ◽  
Kazuno Negishi ◽  
Naoko Kato ◽  
Hidemasa Torii ◽  
Murat Dogru ◽  
...  

2019 ◽  
Vol 45 (10) ◽  
pp. 1446-1451
Author(s):  
Takehiro Matsumura ◽  
Yoshihiro Takamura ◽  
Jun Makita ◽  
Akira Kobori ◽  
Masaru Inatani

Sign in / Sign up

Export Citation Format

Share Document