Embedded sensing package for temporary bone cement spacers in infected total knee arthroplasty

Author(s):  
Michael K. Lavdas ◽  
Ryan Willing ◽  
Brent A. Lanting ◽  
Matthew G. Teeter
2008 ◽  
Vol 69 (03) ◽  
pp. 207-212 ◽  
Author(s):  
S. Dovas ◽  
V. Liakopoulos ◽  
L. Papatheodorou ◽  
I. Chronopoulou ◽  
V. Papavasiliou ◽  
...  

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Hans Bösebeck ◽  
Anna-Maria Holl ◽  
Peter Ochsner ◽  
Manuel Groth ◽  
Kevin Stippich ◽  
...  

Abstract Background In cemented primary total knee arthroplasty (TKA), aseptic loosening remains a major cause for failure. Cementing techniques and characteristics of a chosen cement play a key role for good fixation and implant survival. A pastry bone cement was developed to facilitate the cement preparation and to rule out most of preparation-associated application errors. The pastry bone cement was compared to a conventional polymethyl methacrylate cement in a TKA setting. Methods Standardized implantations of total knee endoprostheses were performed in bilateral knee cadavers to investigate handling properties, variables of cement application, working time, and temperature development. Mechanical aspects and cementation quality were assessed by pull-out trials and microscopic interface analysis. Results Both cements expressed similar characteristics during preparation and application, only the curing time of the pastry cement was about 3 min longer and the temperature peak was lower. Fractures of the conventional cement specimens differed from the pastry cement specimens in the tibial part, while no differences were found in the femoral part. Penetration depth of the pastry cement was similar (tibia) or deeper (femur) compared to the conventional cement. Conclusions The pastry cement facilitates the feasibility of cemented TKA. The pre-clinical tests indicate that the pastry bone cement fulfills the requirements for bone cement in the field of knee arthroplasty. A clinical trial is needed to further investigate the approach and ensure patient safety.


2015 ◽  
Vol 2015 ◽  
pp. 1-3 ◽  
Author(s):  
Dongquan Shi ◽  
Xingquan Xu ◽  
Anyun Guo ◽  
Jin Dai ◽  
Zhihong Xu ◽  
...  

Introduction. Mechanical alignment deviation after total knee arthroplasty is a major reason for early loosening of the prosthesis. Achieving optimum cement penetration during fixation of the femoral and tibial component is an essential step in performing a successful total knee arthroplasty. Bone cement is used to solidify the bone and prosthesis. Thickness imbalance of bone cement leads to the deviation of mechanical alignment. To estimate the influence of bone cement, a retrospective study was conducted.Materials and Methods. A total of 36 subjects were studied. All the TKA were performed following the standard surgical protocol for navigated surgery by medial approach with general anaesthesia. Prostheses were fixed by bone cement.Results. We compared the mechanical axis, flexion/extension, and gap balance before and after cementation. All the factors were different compared with those before and after cementation. Internal rotation was reached with statistical significance (P=0.03).Conclusion. Bone cement can influence the mechanical axis, flexion/extension, and gap balance. It also can prompt us to make a change when poor knee kinematics were detected before cementation.


Author(s):  
Blair S. Ashley ◽  
Javad Parvizi

AbstractTotal knee arthroplasty is a widely successful procedure, but a small percentage of patients have a postoperative course complicated by periprosthetic joint infection (PJI). PJI is a difficult problem to diagnose and to treat, and the management of PJI differs, depending on the acuity of the infection. This paper discusses the established and newer technologies developed for the diagnosis of PJI as well as different treatment considerations and surgical solutions currently available.


Sign in / Sign up

Export Citation Format

Share Document