Application of infrared thermography for in-situ determination of building envelope thermal properties

2019 ◽  
Vol 26 ◽  
pp. 100885
Author(s):  
Xinrui Lu ◽  
Ali Memari
2018 ◽  
Vol 70 ◽  
pp. 03013
Author(s):  
Robert Smusz ◽  
Michał Korzeniowski

In recent time the energy consumption of buildings may be reduced by the application of modern technologies in the construction industry. Modern building materials ensure a reduction of heat losses. However, studies show that thermal bridges may cause up to 30% of the additional heat losses through the building envelope. Therefore, a one key aspect in assessing the real thermal state of buildings is the identification of the heat losses through thermal bridges. The analytical, experimental and numerical methods are used for the assessment of thermal transmittance value of building. In the paper the authors present the experimental research on heat losses through the building under real winter conditions. Infrared thermovision technique has been used to the thermal bridges assessment in situ. IR thermography technique allowed the determination of the influence of thermal bridges on the additional heat losses. For the obtaining the surface emissivity the measurements have been also performed with the use of thermocouples system. Numerical validation of the experimental results has been performed.


2014 ◽  
Vol 933 ◽  
pp. 477-481
Author(s):  
Shuai Chen

Ground source heat pump (GSHP) systems exchange heat with the ground, often through a closed-loop, vertical, borehole heat exchanger (BHE). The performance of the BHE depends on the thermal properties of the ground formation, as well as soil or backfill in the borehole. The design and economic probability of GSHP systems need the thermal conductivity of geological structure and thermal resistance of BHE. Thermal response test (TRT) method allows the in-situ determination of the thermal conductivity (λ) of the ground formation in the vicinity of a BHE, as well as the effective thermal resistance (Rb) of this latter. Thermal properties measured in laboratory experiments do not comply with data of in-situ conditions. The present article describes the results of thermal properties of the BHE whose depth is 100m in Yancheng City, Jiangsu Province, China. As shown in these results, λ and Rb of borehole are determined as 1.84(W·m-1·K-1) and 0.121 (m·K·W-1) respectively.


2004 ◽  
Vol 29 (12) ◽  
pp. 1947-1963 ◽  
Author(s):  
P. Roth ◽  
A. Georgiev ◽  
A. Busso ◽  
E. Barraza

1961 ◽  
Vol 38 (4) ◽  
pp. 545-562 ◽  
Author(s):  
L. Kecskés ◽  
F. Mutschler ◽  
I. Glós ◽  
E. Thán ◽  
I. Farkas ◽  
...  

ABSTRACT 1. An indirect paperchromatographic method is described for separating urinary oestrogens; this consists of the following steps: acidic hydrolysis, extraction with ether, dissociation of phenol-fractions with partition between the solvents. Previous purification of phenol fraction with the aid of paperchromatography. The elution of oestrogen containing fractions is followed by acetylation. Oestrogen acetate is isolated by re-chromatography. The chromatogram was developed after hydrolysis of the oestrogens 'in situ' on the paper. The quantity of oestrogens was determined indirectly, by means of an iron-reaction, after the elution of the iron content of the oestrogen spot, which was developed by the Jellinek-reaction. 2. The method described above is satisfactory for determining urinary oestrogen, 17β-oestradiol and oestriol, but could include 16-epioestriol and other oestrogenic metabolites. 3. The sensitivity of the method is 1.3–1.6 μg/24 hours. 4. The quantitative and qualitative determination of urinary oestrogens with the above mentioned method was performed in 50 pregnant and 9 non pregnant women, and also in 2 patients with granulosa cell tumour.


Sign in / Sign up

Export Citation Format

Share Document