scholarly journals Performance and conversion of the BrightWater ConvertX™ Nephroureteral Stent System

2016 ◽  
Vol 27 (3) ◽  
pp. S131
Author(s):  
B. Smouse ◽  
T. Williams ◽  
K. Stalker ◽  
D. Heilbrunn
2012 ◽  
Vol 50 (08) ◽  
Author(s):  
H Otto ◽  
S Ullrich ◽  
C Rüther ◽  
I Steinbrück ◽  
F Hagenmüller
Keyword(s):  

2021 ◽  
pp. neurintsurg-2021-017469
Author(s):  
Cameron G McDougall ◽  
Orlando Diaz ◽  
Alan Boulos ◽  
Adnan H Siddiqui ◽  
Justin Caplan ◽  
...  

ObjectiveTo evaluate the safety and effectiveness of the Flow Redirection Endoluminal Device (FRED) flow diverter in support of an application for Food and Drug Administration approval in the USA.Methods145 patients were enrolled in a prospective, single-arm multicenter trial. Patients with aneurysms of unfavorable morphology for traditional endovascular therapies (large, wide-necked, fusiform, etc) were included. The trial was designed to demonstrate non-inferiority in both safety and effectiveness, comparing trial results with performance goals (PGs) established from peer-reviewed published literature. The primary safety endpoint was death or major stroke (National Institutes of Health Stroke Scale score ≥4 points) within 30 days of the procedure, or any major ipsilateral stroke or neurological death within the first year. The primary effectiveness endpoint was complete occlusion of the target aneurysm with ≤50% stenosis of the parent artery at 12 months after treatment, and in which an alternative treatment of the target intracranial aneurysm had not been performed.Results145 patients underwent attempted placement of a FRED device, and one or more devices were placed in all 145 patients. 135/145 (93%) had a single device placed. Core laboratory adjudication deemed 106 (73.1%) of the aneurysms large or giant. A safety endpoint was experienced by 9/145 (6.2%) patients, successfully achieving the safety PG of <15%. The effectiveness PG of >46% aneurysm occlusion was also achieved, with the effectiveness endpoint being met in 80/139 (57.6%)ConclusionAs compared with historically derived performance benchmarks, the FRED flow diverter is both safe and effective for the treatment of appropriately selected intracranial aneurysms.Clinical registration numberNCT01801007


Author(s):  
Pasqualino Sirignano ◽  
Eugenio Stabile ◽  
Wassim Mansour ◽  
Laura Capoccia ◽  
Federico Faccenna ◽  
...  
Keyword(s):  

2007 ◽  
Vol 8 (2) ◽  
pp. 99-102 ◽  
Author(s):  
Yoriyasu Suzuki ◽  
Fumiaki Ikeno ◽  
Jennifer K. Lyons ◽  
Tomomi Koizumi ◽  
Alan C. Yeung

2019 ◽  
Vol 276 ◽  
pp. 107-109
Author(s):  
Daniel Quandt ◽  
Walter Knirsch ◽  
Ina Michel-Behnke ◽  
Erwin Kitzmüller ◽  
Miko Obradovic ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document