Multicatheter interstitial brachytherapy versus intensity modulated external beam therapy for accelerated partial breast irradiation: A comparative treatment planning study with respect to dosimetry of organs at risk

2017 ◽  
Vol 122 (1) ◽  
pp. 17-23 ◽  
Author(s):  
Tibor Major ◽  
Gábor Stelczer ◽  
Csilla Pesznyák ◽  
Norbert Mészáros ◽  
Csaba Polgár
2019 ◽  
Vol 53 (1) ◽  
pp. 123-130 ◽  
Author(s):  
Gábor Stelczer ◽  
Tibor Major ◽  
Norbert Mészáros ◽  
Csaba Polgár ◽  
Csilla Pesznyák

Abstract Background The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conformal radiotherapy (3D-CRT), “step and shoot” (SS) and “sliding window” (SW) intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (RA). Patients and methods CT scans of 40 APBI patients were selected for the study. The planning objectives were set up according to the international recommendations. Homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. Results There were no significant differences in the coverage of the target volume between the techniques. The homogeneity indices of 3D-CRT, SS, SW and RA plans were 0.068, 0.074, 0.058 and 0.081, respectively. The conformation numbers were 0.60, 0.80, 0.82 and 0.89, respectively. The V50% values of the ipsilateral breast for 3D-CRT, SS, SW and RA were 47.5%, 40.2%, 39.9% and 31.6%, respectively. The average V10% and V40% values of ipsilateral lung were 13.1%, 28.1%, 28%, 36% and 2.6%, 1.9%, 1.9%, 3%, respectively. The 3D-CRT technique provided the best heart protection, especially in the low dose region. All contralateral organs received low doses. The SW technique achieved the best plan quality index (PQI). Conclusions Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all aspects, we recommend the SW IMRT technique for APBI.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
András Herein ◽  
Gábor Stelczer ◽  
Csilla Pesznyák ◽  
Georgina Fröhlich ◽  
Viktor Smanykó ◽  
...  

Abstract Background The aim of the study was to dosimetrically compare multicatheter interstitial brachytherapy (MIBT) and stereotactic radiotherapy with CyberKnife (CK) for accelerated partial breast irradiation (APBI) especially concerning the dose of organs at risk (OAR-s). Patients and methods Treatment plans of thirty-two MIBT and CK patients were compared. The OAR-s included ipsilateral non-target and contralateral breast, ipsilateral and contralateral lung, skin, ribs, and heart for left-sided cases. The fractionation was identical (4 x 6.25 Gy) in both treatment groups. The relative volumes (e.g. V100, V90) receiving a given relative dose (100%, 90%), and the relative doses (e.g. D0.1cm3, D1cm3) delivered to the most exposed small volumes (0.1 cm3, 1 cm3) were calculated from dose-volume histograms. All dose values were related to the prescribed dose (25 Gy). Results Regarding non-target breast CK performed slightly better than MIBT (V100: 0.7% vs. 1.6%, V50: 10.5% vs. 12.9%). The mean dose of the ipsilateral lung was the same for both techniques (4.9%), but doses irradiated to volume of 1 cm3 were lower with MIBT (36.1% vs. 45.4%). Protection of skin and rib was better with MIBT. There were no significant differences between the dose-volume parameters of the heart, but with MIBT, slightly larger volumes were irradiated by 5% dose (V5: 29.9% vs. 21.2%). Contralateral breast and lung received a somewhat higher dose with MIBT (D1cm3: 2.6% vs. 1.8% and 3.6% vs. 2.5%). Conclusions The target volume can be properly irradiated by both techniques with similar dose distributions and high dose conformity. Regarding the dose to the non-target breast, heart, and contralateral organs the CK was superior, but the nearby organs (skin, ribs, ipsilateral lung) received less dose with MIBT. The observed dosimetric differences were small but significant in a few parameters at the examined patient number. More studies are needed to explore whether these dosimetric findings have clinical significance.