Review of AI applications in harmonic analysis in power systems

2022 ◽  
Vol 154 ◽  
pp. 111897
Author(s):  
Ahmadreza Eslami ◽  
Michael Negnevitsky ◽  
Evan Franklin ◽  
Sarah Lyden
1998 ◽  
Vol 13 (1) ◽  
pp. 180-185 ◽  
Author(s):  
B.C. Smith ◽  
J. Arrillaga ◽  
A.R. Wood ◽  
N.R. Watson

2013 ◽  
Vol 3 (4) ◽  
pp. 467-472 ◽  
Author(s):  
S. F. Mekhamer ◽  
A. Y. Abdelaziz ◽  
S. M. Ismael

Power system harmonics may cause several problems, such as malfunctions of electrical equipment, premature equipment failures and plant shutdowns. Accordingly, mitigation of these harmonics is considered an important target especially for industrial applications where any short downtime period may lead to great economic losses. Harmonic analysis studies are necessary to analyze the current and voltage harmonic levels and check if these levels comply with the contractual or international standard limits. If the studies reveal that the preset limits are exceeded, then a suitable harmonic mitigation technique should be installed. Harmonic analysis studies in the industrial electrical systems are discussed in many references. However, a comprehensive procedure for the steps required to perform a harmonic study is rarely found in the literature even though it is strongly needed for design engineers. This paper provides a comprehensive procedure for the steps required to perform a harmonic study in the form of a flowchart, based on industrial research and experience. Hence, this paper may be considered as a helpful guide for design engineers and consultants of the industrial sector.


Author(s):  
Jayababu Badugu ◽  
Y. P.Obulesu ◽  
Ch. Saibabu

Three-phase Fixed Capacitor Thyristor Controlled Reactor is widely used for reactive power compensation in power systems because of reduced cost and high reliability.  The problem with FC-TCR is that to generate current harmonics when it is partially conducting. When this harmonic current is interacted with system impedance, voltage waveform will distorted. This harmonic pollution is undesirable in power systems. Therefore, it is important to know the harmonic behaviour of three-phase FC-TCR before they can be used in a power system network. This paper presents the harmonic analysis of three-phase FC-TCR operating under balanced and unbalanced conditions. This analysis is useful to design the harmonic filter to reduce the harmonic pollution in power systems.The proposed work is implemented in MATLAB environment.


Sign in / Sign up

Export Citation Format

Share Document