Microstructure of titanium coatings controlled by pulse sequence in multipulse HiPIMS

Author(s):  
Pavel Souček ◽  
Jaroslav Hnilica ◽  
Peter Klein ◽  
Matej Fekete ◽  
Petr Vašin
2018 ◽  
pp. 73-78
Author(s):  
Yu. V. Morozov ◽  
M. A. Rajfeld ◽  
A. A. Spektor

The paper proposes the model of a person seismic signal with noise for the investigation of passive seismic location system characteristics. The known models based on Gabor and Berlage pulses have been analyzed. These models are not able wholly to consider statistical properties of seismic signals. The proposed model is based on almost cyclic character of seismic signals, Gauss character of fluctuations inside a pulse, random amplitude change from pulse to pulse and relatively small fluctuation of separate pulses positions. The simulation procedure consists of passing the white noise through a linear generating filter with characteristics formed by real steps of a person, and the primary pulse sequence modulation by Gauss functions. The model permits to control the signal-to-noise ratio after its reduction to unity and to vary pulse shifts with respect to person steps irregularity. It has been shown that the model of a person seismic signal with noise agrees with experimental data.


2021 ◽  
Vol 23 (15) ◽  
pp. 9457-9465
Author(s):  
Stuart J. Elliott ◽  
Olivier Cala ◽  
Quentin Stern ◽  
Samuel F. Cousin ◽  
Dmitry Eshchenko ◽  
...  

Optimization of a dipolar cross-polarization (dCP) sequence increases the efficiency of 1H polarization transfers to 13C spins in a diverse range of molecular candidates with 13C polarizations surpassing 30%.


2021 ◽  
Vol 49 ◽  
pp. 101556
Author(s):  
Cesare Montesano ◽  
Marzia Faedda ◽  
Luca Matteo Martini ◽  
Giorgio Dilecce ◽  
Paolo Tosi

Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 319
Author(s):  
Chan-Rok Park ◽  
Seong-Hyeon Kang ◽  
Young-Jin Lee

Recently, the total variation (TV) algorithm has been used for noise reduction distribution in degraded nuclear medicine images. To acquire positron emission tomography (PET) to correct the attenuation region in the PET/magnetic resonance (MR) system, the MR Dixon pulse sequence, which is based on controlled aliasing in parallel imaging, results from higher acceleration (CAIPI; MR-ACDixon-CAIPI) and generalized autocalibrating partially parallel acquisition (GRAPPA; MR-ACDixon-GRAPPA) algorithms are used. Therefore, this study aimed to evaluate the image performance of the TV noise reduction algorithm for PET/MR images using the Jaszczak phantom by injecting 18F radioisotopes with PET/MR, which is called mMR (Siemens, Germany), compared with conventional noise-reduction techniques such as Wiener and median filters. The contrast-to-noise (CNR) and coefficient of variation (COV) were used for quantitative analysis. Based on the results, PET images with the TV algorithm were improved by approximately 7.6% for CNR and decreased by approximately 20.0% for COV compared with conventional noise-reduction techniques. In particular, the image quality for the MR-ACDixon-CAIPI PET image was better than that of the MR-ACDixon-GRAPPA PET image. In conclusion, the TV noise-reduction algorithm is efficient for improving the PET image quality in PET/MR systems.


Sign in / Sign up

Export Citation Format

Share Document