The development of matrix reference material of microcystin LR in microcystin aeruginosa

Toxicon ◽  
2019 ◽  
Vol 158 ◽  
pp. S21
Author(s):  
Boqiang Fu ◽  
Zhiyu Tang ◽  
Jing Wang
Metrologia ◽  
2014 ◽  
Vol 51 (1A) ◽  
pp. 06007-06007 ◽  
Author(s):  
U Wätjen ◽  
T Altzitzogloa ◽  
A Ceccatelli ◽  
H Dikmen ◽  
L Ferreux ◽  
...  

2015 ◽  
Vol 407 (30) ◽  
pp. 9153-9163 ◽  
Author(s):  
Jun Li ◽  
Yuhua Wu ◽  
Xiaofei Li ◽  
Yulei Wang ◽  
Li Zhang ◽  
...  

2015 ◽  
Vol 407 (18) ◽  
pp. 5353-5363 ◽  
Author(s):  
Christie Hollingdale ◽  
Krista Thomas ◽  
Nancy Lewis ◽  
Khalida Békri ◽  
Pearse McCarron ◽  
...  

2021 ◽  
Vol 26 (2) ◽  
pp. 77-90
Author(s):  
Xuqian Guo ◽  
Yinghua Cai ◽  
Hongbin Liu ◽  
Ying Li ◽  
Lei Yu ◽  
...  

2010 ◽  
Vol 56 (12) ◽  
pp. 1880-1888 ◽  
Author(s):  
Ingrid Zegers ◽  
Thomas Keller ◽  
Wiebke Schreiber ◽  
Joanna Sheldon ◽  
Riccardo Albertini ◽  
...  

BACKGROUND The availability of a suitable matrix reference material is essential for standardization of the immunoassays used to measure serum proteins. The earlier serum protein reference material ERM-DA470 (previously called CRM470), certified in 1993, has led to a high degree of harmonization of the measurement results. A new serum protein material has now been prepared and its suitability in term of homogeneity and stability has been verified; after characterization, the material has been certified as ERM-DA470k/IFCC. METHODS We characterized the candidate reference material for 14 proteins by applying a protocol that is considered to be a reference measurement procedure, by use of optimized immunoassays. ERM-DA470 was used as a calibrant. RESULTS For 12 proteins [α2 macroglobulin (A2M), α1 acid glycoprotein (orosomucoid, AAG), α1 antitrypsin (α1-protease inhibitor, AAT), albumin (ALB), complement 3c (C3c), complement 4 (C4), haptoglobin (HPT), IgA, IgG, IgM, transferrin (TRF), and transthyretin (TTR)], the results allowed assignment of certified values in ERM-DA470k/IFCC. For CRP, we observed a bias between the lyophilized and liquid frozen materials, and for CER, the distribution of values was too broad. Therefore, these 2 proteins were not certified in the ERM-DA470k/IFCC. Different value transfer procedures were tested (open and closed procedures) and found to provide equivalent results. CONCLUSIONS A new serum protein reference material has been produced, and values have been successfully assigned for 12 proteins.


Sign in / Sign up

Export Citation Format

Share Document