In Vivo Validation of Volume Flow Measurements of Pulsatile Flow Using a Clinical Ultrasound System and Matrix Array Transducer

2017 ◽  
Vol 43 (3) ◽  
pp. 579-585 ◽  
Author(s):  
John M. Hudson ◽  
Ross Williams ◽  
Laurent Milot ◽  
Qifeng Wei ◽  
James Jago ◽  
...  
1995 ◽  
Vol 33 (6) ◽  
pp. 778-784 ◽  
Author(s):  
Mark B. M. Hofman ◽  
Frans C. Visser ◽  
Albert C. Van Rossum ◽  
Ger Q. M. Vink ◽  
Michiel Sprenger ◽  
...  

2011 ◽  
Vol 300 (6) ◽  
pp. H2096-H2104 ◽  
Author(s):  
Zhang Zhang ◽  
Shigeho Takarada ◽  
Sabee Molloi

Structural coronary microcirculation abnormalities are important prognostic determinants in clinical settings. However, an assessment of microvascular resistance (MR) requires a velocity wire. A first-pass distribution analysis technique to measure volumetric blood flow has been previously validated. The aim of this study was the in vivo validation of the MR measurement technique using first-pass distribution analysis. Twelve anesthetized swine were instrumented with a transit-time ultrasound flow probe on the proximal segment of the left anterior descending coronary artery (LAD). Microspheres were injected into the LAD to create a model of microvascular dysfunction. Adenosine (400 μg·kg−1·min−1) was used to produce maximum hyperemia. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. Volumetric blood flow measurements (Qa) were made using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. Blood flow from the flow probe (Qp), coronary pressure (Pa), and right atrium pressure (Pv) were continuously recorded. Flow probe-based normalized MR (NMRp) and angiography-based normalized MR (NMRa) were calculated using Qp and Qa, respectively. In 258 measurements, Qa showed a strong correlation with the gold standard Qp (Qa = 0.90 Qp + 6.6 ml/min, r2 = 0.91, P < 0.0001). NMRa correlated linearly with NMRp (NMRa = 0.90 NMRp + 0.02 mmHg·ml−1·min−1, r2 = 0.91, P < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between NMRa and NMRp. In conclusion, a technique based on angiographic image data for quantifying NMR was validated using a swine model. This study provides a method to measure NMR without using a velocity wire, which can potentially be used to evaluate microvascular conditions during coronary arteriography.


1994 ◽  
Vol 31 (3) ◽  
pp. 153-160 ◽  
Author(s):  
J. Craig Hartman ◽  
Douglas A. Olszanski ◽  
Thomas G. Hullinger ◽  
Marshall N. Brunden

2016 ◽  
Vol 42 (4) ◽  
pp. 971-979 ◽  
Author(s):  
Jessica Kishimoto ◽  
Aaron Fenster ◽  
David S.C. Lee ◽  
Sandrine de Ribaupierre

2014 ◽  
Author(s):  
J. Kishimoto ◽  
A. Fenster ◽  
N. Chen ◽  
D. Lee ◽  
S. de Ribaupierre

Sign in / Sign up

Export Citation Format

Share Document