Lateral Mass of C1 Fixation and Ponticulus-Posticus

2014 ◽  
Vol 82 (1-2) ◽  
pp. e145-e146 ◽  
Author(s):  
Faiz U. Ahmad ◽  
Michael Y. Wang
2018 ◽  
Vol 113 ◽  
pp. e579-e585 ◽  
Author(s):  
Dilek Arslan ◽  
Mehmet Asim Ozer ◽  
Figen Govsa ◽  
Omer Kıtıs

2021 ◽  
Author(s):  
William W Wroe ◽  
Bradley Budde ◽  
Joseph C Hsieh

Abstract BACKGROUND AND IMPORTANCE Fractures of C2 are typically managed nonoperatively with good rates of healing. Management decisions are complicated, however, when there are additional fractures in the axis possibly leading to increased instability. Additionally, the techniques used for treating these unstable axis fractures can have either significant complications or permanent loss of range of motion. Here, we present a novel technique for the reduction and stabilization of complex C2 body fracture. CLINICAL PRESENTATION A 34-yr-old woman with a complex C2 body fracture, which included a right pars and left lateral mass fracture, presented after a water slide accident. It was felt that this fracture was both unstable and would not heal in an anatomically acceptable way so an open surgical reduction was needed. After consideration of more traditional fusion and osteosynthesis techniques, we chose to perform a C1-C2 internal stabilization with C1 sublaminar and C2 spinous process wiring. The patient was then instructed to wear a Miami J collar for 3 mo. CONCLUSION The outcome was favorable with good approximation and healing with preserved range of motion.


2011 ◽  
Vol 14 (3) ◽  
pp. 405-411 ◽  
Author(s):  
Kalil G. Abdullah ◽  
Amy S. Nowacki ◽  
Michael P. Steinmetz ◽  
Jeffrey C. Wang ◽  
Thomas E. Mroz

Object The C-7 lateral mass has been considered difficult to fit with instrumentation because of its unique anatomy. Of the methods that exist for placing lateral mass screws, none particularly accommodates this anatomical variation. The authors have related 12 distinct morphological measures of the C-7 lateral mass to the ability to place a lateral mass screw using the Magerl, Roy-Camille, and a modified Roy-Camille method. Methods Using CT scans, the authors performed virtual screw placement of lateral mass screws at the C-7 level in 25 male and 25 female patients. Complications recorded included foraminal and articular process violations, inability to achieve bony purchase, and inability to place a screw longer than 6 mm. Violations were monitored in the coronal, axial, and sagittal planes. The Roy-Camille technique was applied starting directly in the middle of the lateral mass, as defined by Pait's quadrants, with an axial angle of 15° lateral and a sagittal angle of 90°. The Magerl technique was performed by starting in the inferior portion of the top right square of Pait's quadrants and angling 25° laterally in the axial plane with a 45° cephalad angle in the sagittal plane. In a modified method, the starting point is similar to the Magerl technique in the top right square of Pait's quadrant and then angling 15° laterally in the axial plane. In the sagittal plane, a 90° angle is taken perpendicular to the dorsal portion of the lateral mass, as in the traditional Roy-Camille technique. Results Of all the morphological methods analyzed, only a combined measure of intrusion of the T-1 facet and the overall length of the C-7 lateral mass was statistically associated with screw placement, and only in the Roy-Camille technique. Use of the Magerl technique allowed screw placement in 28 patients; use of the Roy-Camille technique allowed placement in 24 patients; and use of the modified technique allowed placement in 46 patients. No screw placement by any method was possible in 4 patients. Conclusions There is only one distinct anatomical ratio that was shown to affect lateral mass screw placement at C-7. This ratio incorporates the overall length of the lateral mass and the amount of space occupied by the T-1 facet at C-7. Based on this virtual study, a modified Roy-Camille technique that utilizes a higher starting point may decrease the complication rate at C-7 by avoiding placement of the lateral mass screw into the T1 facet.


Sign in / Sign up

Export Citation Format

Share Document