scholarly journals Real-time monitoring of pressure and temperature of oil well using a carbon-coated and bellow-packaged optical fiber sensor

2021 ◽  
Vol 67 ◽  
pp. 102703
Author(s):  
Ying-Ying Wang ◽  
Fa-Xiang Zhang ◽  
Qing-Chao Zhao ◽  
Chuan-Rui Che
2017 ◽  
Vol 265 ◽  
pp. 193-201 ◽  
Author(s):  
Wern Kam ◽  
Kieran O'Sullivan ◽  
Mary O'Keeffe ◽  
Sinead O'Keeffe ◽  
Waleed S. Mohammed ◽  
...  

2013 ◽  
Vol 416-417 ◽  
pp. 971-974
Author(s):  
Shi Sheng Guo ◽  
Ying Ying Wang ◽  
Chang Wang ◽  
Xiao Hui Liu

Optical fiber sensors have been used widely in offshore oilfield. An optical fiber sensor system including an optical fiber sensor testing temperature and pressure under well, a connector connecting the optical fiber sensor with the optical cable, two connectors connecting cables, 3600 meters armoured optical cable and an interrogator was applied in an offshore oil well on Zhoushan island. The temperature and pressure under well have been measured for about two month and the testing results are presented in this paper.


Author(s):  
Ana Maria Cao y Paz ◽  
Jorge Marcos Acevedo ◽  
Jesus Doval Gandoy ◽  
Alfredo del Rio Vazquez ◽  
Carlos Martinez-Penalver Freire ◽  
...  

2017 ◽  
Author(s):  
Hongtao Zhang ◽  
Wei Fu ◽  
Chunqian Wang ◽  
Guangyu Zhang ◽  
Zhenlong Wang

AIP Advances ◽  
2018 ◽  
Vol 8 (7) ◽  
pp. 075019
Author(s):  
Wanshan Zhu ◽  
Junfeng Jiang ◽  
Jin Wang ◽  
Xinggang Liu ◽  
Tiegen Liu

2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Hyuk-Jin Yoon ◽  
Kwang-Yong Song ◽  
Chanyong Choi ◽  
Hee-Seoung Na ◽  
Jung-Seok Kim

This study demonstrates the monitoring of distributed strain of rail and girder of a railway bridge occurring during train passage over the bridge’s entire section on a real-time basis by applying a developed distributed optical fiber sensor based on Brillouin Optical Correlation Domain Analysis (BOCDA). The distributed optical fiber sensor system and an algorithm to control as well as to analyze Brillouin gain spectrum signals were also developed. A single-mode optical fiber was attached in the longitudinal direction on the rail and the lower flange of the girder to be used as a sensing fiber of the BOCDA system. Changes in the girder’s strain at the center point of the bridge during the passage of a commercial train were measured at 9 Hz, and the accuracy of this measurement was validated by comparing the measured data with the data from strain gauge. In addition, the distributed strain of a girder and the rail with a length of 40.26 m was measured in real time with a spatial resolution of 31.1 cm. Based on the results of the rail’s strain distribution, the study could identify the location where excessive strain occurred due to an influence of unsupported sleepers on girder of the bridge.


2009 ◽  
Author(s):  
Eric Fujiwara ◽  
Rafael T. Takeishi ◽  
Eduardo Ono ◽  
J. S. dos Santos ◽  
Aya Hase ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document