scholarly journals EP-1702: Cardiac dose evaluation in left breast cancer radiotherapy: Direct and Helical Tomotherapy

2016 ◽  
Vol 119 ◽  
pp. S795-S796
Author(s):  
A. Fozza ◽  
L. Berta ◽  
S. Aimonetto ◽  
F. Migliaccio ◽  
A. Peruzzo Cornetto ◽  
...  
2021 ◽  
Vol 20 ◽  
pp. 153303382110537
Author(s):  
Jianjian Qiu ◽  
Shujun Zhang ◽  
Bo Lv ◽  
Xiangpeng Zheng

Purpose: A novel in-house technology “Non-Uniform VMAT (NU-VMAT)” was developed for automated cardiac dose reduction and treatment planning optimization in the left breast radiotherapy. Methods: The NU-VMAT model based on IGM (gantry MLC Movement coefficient index) was established to optimize the volumetric modulated arc therapy (VMAT) MLC movement and modulation intensity in certain gantry angles. The ESAPI embedded in Eclipse® was employed to connect TPS and the optimization program via I/O relevant DICOM RT files. The adjuvant whole-breast radiotherapy of 14 patients with left breast cancer was replanned using our NU-VMAT technology in comparison with VMAT and IMRT technology. Dosimetric parameters including D1%, D99%, and Dmean of PTV, V5, V10, and V20 of ipisilateral lung, V5, D20, D30, and Dmean of heart, monitor units (MUs), and delivery time derived from IMRT, VMAT, and NU-VMAT plans were evaluated for plan quality and delivery efficiency. The quality assurance (QA) was conducted using both point-dose and planar-dose measurements for all treatment plans. Results: The IGM−NU−VMAT curves with plan optimization (range from 50% to 147%) were converged more significantly than IGM-VMAT curves (range from 0% to 297%). The dose distribution requirements of the target and normal tissues could be met using IMRT, VMAT, or NU-VMAT; the lowest Dmean was achieved in NU-VMAT plans (5.38 ± 0.46 Gy vs 5.63 ± 0.61 Gy in IMRT and 7.95 ± 0.52 Gy in VMAT plans). Statistically significant differences were found in terms of delivery time and MU when comparing IMRT with VMAT and NU-VMAT plans ( P < .05). In comparison with IMRT plans, the MU and delivery time in NU-VMAT plans dramatically decreased by 69.8% and 28.4%, respectively. Moreover, NU-VMAT plans showed a high gamma passing rate (96.5% ± 1.11) in plane dose verification and minimal dose difference (2.4% ± 0.19) in point absolute dose verification. Conclusion: Our non-uniform VMAT facilitated the treatment strategy optimization for left breast cancer radiotherapy with dosimetric advantage in cardiac dose reduction and delivery efficiency in comparison with the conventional VMAT and IMRT.


2018 ◽  
Vol 09 (02) ◽  
Author(s):  
Eda Kucuktulu ◽  
Ahmet Fatih Yurekli ◽  
Eray Bilcan ◽  
Mahmut Serdar Sisecioglu ◽  
Murat Topbas and Uzer Kucuktulu

2014 ◽  
Vol 112 (1) ◽  
pp. 9-16 ◽  
Author(s):  
Chirag Shah ◽  
Shahed Badiyan ◽  
Sameer Berry ◽  
Atif J. Khan ◽  
Sharad Goyal ◽  
...  

2013 ◽  
Vol 108 (2) ◽  
pp. 248-253 ◽  
Author(s):  
Mirjam E. Mast ◽  
Loes van Kempen-Harteveld ◽  
Mark W. Heijenbrok ◽  
Yamoena Kalidien ◽  
Hans Rozema ◽  
...  

2016 ◽  
Vol 8 (8) ◽  
pp. 735 ◽  
Author(s):  
Olivier Lauche ◽  
Youlia M Kirova ◽  
Pascal Fenoglietto ◽  
Emilie Costa ◽  
Claire Lemanski ◽  
...  