dose sparing
Recently Published Documents


TOTAL DOCUMENTS

164
(FIVE YEARS 44)

H-INDEX

23
(FIVE YEARS 3)

2021 ◽  
Vol 26 (50) ◽  
Author(s):  
Edoardo Colzani ◽  
Kari Johansen ◽  
Helen Johnson ◽  
Lucia Pastore Celentano

While many European Union/European Economic Area (EU/EEA) countries recently expanded human papillomavirus (HPV) vaccination to boys, HPV vaccine supply is currently limited for girls in low- and middle-income countries (LMIC) that are severely affected by HPV. Globally, about 50% of countries have introduced HPV vaccination. Some LMIC with high burden of cervical cancer have not yet introduced HPV vaccination, or are reaching suboptimal vaccination coverage. While WHO issued a call for cervical cancer elimination in 2018, a global shortage of HPV vaccines is currently predicted to last at least until 2024. We reviewed national policies of EU/EEA countries and recommendations of the World Health Organization (WHO) Strategic Advisory Group of Experts on immunisation to discuss current challenges and dose-sparing options. Several EU/EEA countries have extended HPV vaccination to boys and the European Cancer Organisation has issued a resolution for elimination of all HPV-associated cancers in both sexes. The European Centre for Disease Prevention and Control concluded in its 2020 guidance that cost-effectiveness of extending routine vaccination to boys depends on several context-specific factors. The extension of HPV vaccination to boys in EU/EEA countries may affect global availability of vaccines. Temporary dose-sparing options could be considered during the COVID-19 post-pandemic period.


EBioMedicine ◽  
2021 ◽  
Vol 72 ◽  
pp. 103586
Author(s):  
Stephen J Kent ◽  
Jennifer A Juno
Keyword(s):  

BMJ Open ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. e050596
Author(s):  
Carole Lunny ◽  
Jesmin Antony ◽  
Patricia Rios ◽  
Chantal Williams ◽  
Naveeta Ramkissoon ◽  
...  

BackgroundThe objective of this rapid scoping review was to identify studies of dose-sparing strategies for administration of intramuscular seasonal influenza vaccines in healthy individuals of all ages.MethodsComprehensive literature searches were executed in MEDLINE, Embase and the Cochrane library. The grey literature was searched via international clinical trial registries for relevant studies published in English in the last 20 years. We included studies in healthy humans of any age that used any dose-sparing strategy to administer intramuscular seasonal influenza vaccines. Title/abstract and full-text screening were carried out by pairs of reviewers independently. Data extraction was conducted by a single reviewer and verified by a second reviewer. Our outcomes were influenza infections, intensive care unit admission, pneumonia, hospitalisations, adverse events and mortality. Results were summarised descriptively.ResultsA total of 13 studies with 10 351 participants were included in the review and all studies were randomised controlled trials (RCTs) conducted between 2006 and 2019. The most common interventions were the trivalent influenza vaccine (n=10), followed by the quadrivalent influenza vaccine (n=4). Nine studies included infants/toddlers 6–36 months old and one of these studies also included children and adolescents. In these nine studies, no clinical effectiveness outcomes were reported. Of the four adult studies (≥18 years), two studies reported on effectiveness outcomes, however, only one RCT reported on laboratory-confirmed influenza.ConclusionsDue to the low number of studies in healthy adults and the lack of studies assessing confirmed influenza and influenza-like illness, there remains a need for further evaluation.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Zhigong Wei ◽  
Xingchen Peng ◽  
Yan Wang ◽  
Lianlian Yang ◽  
Ling He ◽  
...  

Abstract Objective To evaluate the influence of target dose heterogeneity on normal tissue dose sparing for peripheral lung tumor stereotactic body radiation therapy (SBRT). Methods Based on the volumetric-modulated arc therapy (VMAT) technique, three SBRT plans with homogeneous, moderate heterogeneous, and heterogeneous (HO, MHE, and HE) target doses were compared in 30 peripheral lung tumor patients. The prescription dose was 48 Gy in 4 fractions. Ten rings outside the PTV were created to limit normal tissue dosage and evaluate dose falloff. Results When MHE and HE plans were compared to HO plans, the conformity index of the PTV was increased by approximately 0.08. The median mean lung dose (MLD), V5, V10, V20 of whole lung, D2%, D1cc, D2cc of the rib, V30 of the rib, D2% and the maximum dose (Dmax) of the skin, and D2% and Dmax of most mediastinal organs at risk (OARs) and spinal cord were reduced by up to 4.51 Gy or 2.8%. Analogously, the median Dmax, D2% and mean dose of rings were reduced by 0.71 to 8.46 Gy; and the median R50% and D2cm were reduced by 2.1 to 2.3 and 7.4% to 8.0%, respectively. Between MHE and HE plans there was little to no difference in OARs dose and dose falloff beyond the target. Furthermore, the dose sparing of rib V30 and the mean dose of rings were negatively correlated with the rib and rings distance from tumor, respectively. Conclusions For peripheral lung tumor SBRT, target conformity, normal tissue dose, and dose falloff around the target could be improved by loosening or abandoning homogeneity. While there was negligible further dose benefit for the maximum target dose above 125% of the prescription, dose sparing of normal tissue derived from a heterogeneous target decreased as the distance from the tumor increased.


2021 ◽  
Vol 11 ◽  
Author(s):  
Hyunsoo Jang ◽  
Jiyeon Park ◽  
Mark Artz ◽  
Yawei Zhang ◽  
Jacob C. Ricci ◽  
...  

BackgroundAlthough there are some controversies regarding whole pelvic radiation therapy (WPRT) due to its gastrointestinal and hematologic toxicities, it is considered for patients with gynecological, rectal, and prostate cancer. To effectively spare organs-at-risk (OAR) doses using multi-leaf collimator (MLC)’s optimal segments, potential dosimetric benefits in volumetric modulated arc therapy (VMAT) using a half-beam technique (HF) were investigated for WPRT.MethodsWhile the size of a fully opened field (FF) was decided to entirely include a planning target volume in all beam’s eye view across arc angles, the HF was designed to use half the FF from the isocenter for dose optimization. The left or the right half of the FF was alternatively opened in VMAT-HF using a pair of arcs rotating clockwise and counterclockwise. Dosimetric benefits of VMAT-HF, presented with dose conformity, homogeneity, and dose–volume parameters in terms of modulation complex score, were compared to VMAT optimized using the FF (VMAT-FF). Consequent normal tissue complication probability (NTCP) by reducing the irradiated volumes was evaluated as well as dose–volume parameters with statistical analysis for OAR. Moreover, beam-on time and MLC position precision were analyzed with log files to assess plan deliverability and clinical applicability of VMAT-HF as compared to VMAT-FF.ResultsWhile VMAT-HF used 60%–70% less intensity modulation complexity than VMAT-FF, it showed superior dose conformity. The small intestine and colon in VMAT-HF showed a noticeable reduction in the irradiated volumes of up to 35% and 15%, respectively, at an intermediate dose of 20–45 Gy. The small intestine showed statistically significant dose sparing at the volumes that received a dose from 15 to 45 Gy. Such a dose reduction for the small intestine and colon in VMAT-HF presented a significant NTCP reduction from that in VMAT-FF. Without sacrificing the beam delivery efficiency, VMAT-HF achieved effective OAR dose reduction in dose–volume histograms.ConclusionsVMAT-HF led to deliver conformal doses with effective gastrointestinal-OAR dose sparing despite using less modulation complexity. The dose of VMAT-HF was delivered with the same beam-on time with VMAT-FF but precise MLC leaf motions. The VMAT-HF potentially can play a valuable role in reducing OAR toxicities associated with WPRT.


2021 ◽  
Vol 161 ◽  
pp. S1620
Author(s):  
C. Abraham ◽  
O. Nicholas ◽  
R. Lewis ◽  
A. Selby ◽  
H. Wong ◽  
...  

2021 ◽  
Author(s):  
Geert V.T. Roozen ◽  
Manon Prins ◽  
Rob van Binnendijk ◽  
Gerco den ◽  
Vincent Kuiper ◽  
...  

Background There is an urgent need for fair and equitable access to safe and effective vaccines to end the COVID-19 pandemic. Shortages in reagents and vaccines are a major challenge, as well as limited knowledge on dose response relationship with mRNA COVID-19 vaccines. We explored intradermal fractional dose administration of a mRNA SARS-CoV-2/COVID-19 vaccine as a potential dose-sparing strategy. Methods We conducted a proof-of-concept, dose-escalation, open-label, randomised-controlled vaccine trial (IDSCOVA) in healthy adults aged 18-30 years. To test initial safety, ten participants received 10 μg mRNA-1273 vaccine through intradermal injection at day 1 and 29. Following a favourable safety review, thirty participants were 1:1 randomised to receive 20 μg mRNA-1273 either intradermally or intramuscularly. The primary endpoint was tolerability and safety. The secondary endpoint was seroconversion and specific IgG concentration against SARS-CoV-2 spike S1 and Receptor Binding Domain (RBD) after the second dose at day 43. We compared results to two historical cohorts of non-hospitalised COVID-19 patients and vaccinated individuals. Findings Thirty-eight of forty included participants (median age 25 years) completed the study. There were no serious adverse events. Self-reported local adverse reactions after intradermal delivery were mild, both in the 10 μg and the 20 μg group. In the higher dose group, systemic adverse reactions were more common, but still well tolerated. All 38 participants mounted substantially higher IgG-anti-S1 and IgG-anti-RBD concentrations at day 43 than COVID-19 controls. At day 43, anti-S1 (95% CI) was 1,696 (1,309-2,198) BAU/mL for the 10 μg intradermal group, 1,406 (953.5-2,074) BAU/mL for the 20 μg intramuscular group and 2,057 (1,421-2,975) BAU/mL for the 20 μg intradermal group. Anti-S1 was 107.2 (63-182.2) BAU/mL for the convalescent plasma control group and 1,558 (547.8-4,433) BAU/mL for the individuals vaccinated with 100 μg mRNA-1273. Interpretation Intradermal administration of 10 μg and 20 μg mRNA-1273 vaccine was well tolerated and safe, and resulted in a robust antibody response. Intradermal vaccination has the potential to be deployed for vaccine dose-sparing.


Sign in / Sign up

Export Citation Format

Share Document