scholarly journals EP-1140: Dosimetric comparison between Helical Tomotherapy and IMRT for Bilateral Breast Cancer

2017 ◽  
Vol 123 ◽  
pp. S621
Author(s):  
M.H. Wang
Author(s):  
Reena Phurailatpam ◽  
Tabassum Wadasadawala ◽  
Kamalnayan Chauhan ◽  
Subhajit Panda ◽  
Rajiv Sarin

Abstract Purpose: Dosimetric comparison between volumetric-modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of bilateral breast cancer (BBC). Materials and methods: Ten patients treated on HT were selected retrospectively. Dose prescription was 50 Gy in 25 fractions to breast/chest wall and supraclavicular fossa (SCF) while tumour bed was simultaneously boosted to 61 Gy in 25 fractions. VMAT plans were made with four mono-isocentric partial arcs. The monitoring unit (MU) and treatment time were used to quantify the treatment efficiency. Target volumes were compared for homogeneity index (HI), conformity index (CI) while organs at risk (OARs) were compared for relevant dose volumes and integral doses (IDs). Result: For targets, no significant difference is observed between VMAT and HT in CI but VMAT could give better HI. The mean lung dose, V20 and V5 is 10·6 Gy versus 8·4 Gy (p-value 0·03), 12% versus 11·5% (p-value 0·5) and 78·1% versus 43·4% (p-value 0·005), respectively. The mean heart dose, V30 and V5 is 4·9 Gy versus 4·7 Gy (p-value 0·88), 0·5% versus 1·5% (p-value 0·18) and 26·2% versus 22·8% (p-value 0·4). Integral dose (ID) for the whole body and heart are comparable: 289 Gy kg versus 299 Gy kg (p-value 0·24) and 2·9 Gy kg versus 2·8 Gy kg (p-value 0·80). ID for lungs was significantly higher with VMAT: 7·9 Gy kg versus 6·3 Gy kg (p-value 0·03). There is a 53% reduction in treatment time and 78% in MU with VMAT against HT. Conclusion: VMAT can generate clinically acceptable plans comparable to HT for BBC. HT shows better control over low dose spillage in lungs compared to VMAT thereby increasing ID to lungs. VMAT shows better homogeneity and efficient treatment delivery than HT.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Hilde Van Parijs ◽  
Truus Reynders ◽  
Karina Heuninckx ◽  
Dirk Verellen ◽  
Guy Storme ◽  
...  

Background. Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining normofractionation on the breast.Methods. For 10 patients 4 treatment plans were deployed, 1 with a sequential photon boost, and 3 with different SIB techniques: on a conventional linear accelerator, helical TomoTherapy, and static TomoDirect. Dosimetric comparison was performed.Results. PTV-coverage was good in all techniques. Conformity was better with all SIB techniques compared to sequential boost (P= 0.0001). There was less dose spilling to the ipsilateral breast outside the PTVboost (P= 0.04). The dose to the organs at risk (OAR) was not influenced by SIB compared to sequential boost. Helical TomoTherapy showed a higher mean dose to the contralateral breast, but less than 5 Gy for each patient.Conclusions. SIB showed less dose spilling within the breast and equal dose to OAR compared to sequential boost. Both helical TomoTherapy and the conventional technique delivered acceptable dosimetry. SIB seems a safe alternative and can be implemented in clinical routine.


2017 ◽  
Vol 90 (1077) ◽  
pp. 20170152 ◽  
Author(s):  
Tabassum Wadasadawala ◽  
Shanu Jain ◽  
Siji Paul ◽  
Reena Phurailatpam ◽  
Kishore Joshi ◽  
...  