field technique
Recently Published Documents


TOTAL DOCUMENTS

440
(FIVE YEARS 33)

H-INDEX

30
(FIVE YEARS 1)

2021 ◽  
Author(s):  
Jussi Silvonen ◽  
Niko Järvelä ◽  
Markus Koppanen ◽  
Matti Järveläinen ◽  
Arto Ojuva ◽  
...  

AbstractOnline control of industrial processes by lean principle increases productivity and yields higher product quality. Polysaccharides are dissolved in liquids, such as water, in many industrial products, like paints, cosmetics and culinary products. In these products, it is important to control viscosity or create thixotropy and yield stress for product functionality. Electromagnetic field and electrical conductivity techniques were applied to a meter polysaccharide dissolution process online up to a 0.5 wt% concentration, and the resultant solution was also further tested by UV–Vis spectrophotometry. The electromagnetic field technique measures changes in the local electrical permittivity of the liquid and the interest in this research were to find out whether the changes correlate to the concentration changes during the dissolution of polymer polysaccharide. The results that were obtained showed good consistency, suggesting the feasibility of the electromagnetic field technique in online monitoring of a polysaccharide suspension concentration. Moreover, this technique gives the advantage of instant monitoring of a polysaccharide dissolution for improved process control. Graphic abstract


Author(s):  
Manindra Bhushan ◽  
Deepak Tripathi ◽  
Girigesh Yadav ◽  
Lalit Kumar ◽  
Rahul Lal Chowdhary ◽  
...  

Abstract Background The number of people with implanted hip prosthesis has grown worldwide. For radiotherapy planning of patients with hip implants, few main challenges are encountered. The aim of the present study was to evaluate the feasibility of different planning algorithms in the presence of high-density metallic implant in the treatment of patients with carcinoma cervix. Results It was found that D98% were 44.49 ± 0.11, 44.51 ± 0.13, 44.39 ± 0.22, and 44.45 ± 0.16 Gy for 4FMC6MV (4-field technique calculated with Monte-Carlo algorithm and 6 MV photon energy), 4FMC6MV_WP (4-field technique calculated with Monte-Carlo algorithm and 6 MV photon energy without prosthesis), 4FCC6MV (4-field technique calculated with collapse-cone-convolution algorithm and 6 MV photon energy), and 4FCC6MV_WP (4-field technique calculated with collapse-cone-convolution algorithm and 6 MV photon energy without prosthesis) respectively. Similarly, D2% were 49.40 ± 0.84, 49.05 ± 0.76, 48.97 ± 0.91, and 48.57 ± 0.85 Gray (Gy) for 4FMC6MV, 4FMC6MV_WP, 4FCC6MV, and 4FCC6MV_WP respectively. The present study has not suggested any major difference between the Monte-Carlo (MC) and collapse-cone-convolution (CCC) calculation algorithm in the presence of high-Z metallic implants. Volume of bowel receiving 15 Gy dose has shown a significant difference with prosthesis cases. This study investigates that hip prosthesis creates considerable changes in the treatment planning of cervical malignancies. Conclusion CCC algorithm is in good agreement with MC calculation algorithm in the presence of high-density metallic implants in terms of target coverage and avoidance organ sparing except few parameters.


2021 ◽  
Vol 10 (03) ◽  
pp. 35-43
Author(s):  
Bidyapati Jha ◽  
Hari Prasad Lamichhane ◽  
GisupNikha Prasiko ◽  
Raju Prasad Srivastava

2020 ◽  
Vol 217 (24) ◽  
pp. 2000537
Author(s):  
Shailendra Kr. Singh ◽  
Uttam Kr. Samanta ◽  
Anirban Dhar ◽  
Mrinmay Pal ◽  
Mukul Chandra Paul

Sign in / Sign up

Export Citation Format

Share Document