PO-1552 Fraction ΔNTCP calculation using automatic 4D accumulated dose in IMPT for thoracic indications

2021 ◽  
Vol 161 ◽  
pp. S1276-S1278
Author(s):  
A.C. Hengeveld ◽  
C.O. Ribeiro ◽  
A. Meijers ◽  
C.T. Muijs ◽  
A. Crijns ◽  
...  
Keyword(s):  
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Yang Li ◽  
Yoshiki Kubota ◽  
Masahiko Okamoto ◽  
Shintaro Shiba ◽  
Shohei Okazaki ◽  
...  

Abstract Background Daily anatomical deviations may distort the dose distribution in carbon ion radiotherapy (CIRT), which may cause treatment failure. Therefore, this study aimed to perform re-planning to maintain the dose coverage in patients with pancreatic cancer with passive scattering CIRT. Methods Eight patients with pancreatic cancer and 95 daily computed tomography (CT) sets were examined. Two types of adaptive plans based on new range compensators (RCs) (AP-1) and initial RCs (AP-2) were generated. In AP-2, each beam was optimized by manually adjusting the range shifter thickness and spread-out Bragg peak size to make dose reduction by < 3% of the original plan. Doses of the original plan with bone matching (BM) and tumor matching (TM) were examined for comparison. We calculated the accumulated dose using the contour and intensity-based deformable image registration algorithm. The dosimetric differences in respect to the original plan were compared between methods. Results Using TM and BM, mean ± standard deviations of daily CTV V95 (%) difference from the original plan was − 5.1 ± 6.2 and − 8.8 ± 8.8, respectively, but 1.2 ± 3.4 in AP-1 and − 0.5 ± 2.1 in AP-2 (P < 0.001). AP-1 and AP-2 enabled to maintain a satisfactory accumulated dose in all patients. The dose difference was 1.2 ± 2.8, − 2,1 ± 1.7, − 7.1 ± 5.2, and − 16.5 ± 15.0 for AP-1, AP-2, TM, and BM, respectively. However, AP-2 caused a dose increase in the duodenum, especially in the left–right beam. Conclusions The possible dose deterioration should be considered when performing the BM, even TM. Re-planning based on single beam optimization in passive scattering CIRT seems an effective and safe method of ensuring the treatment robustness in pancreatic cancer. Further study is necessary to spare healthy tissues, especially the duodenum.


2020 ◽  
Vol 152 ◽  
pp. S308
Author(s):  
M. Boekhoff ◽  
I. Defize ◽  
A. Kotte ◽  
N. Takahashi ◽  
J. Lagendijk ◽  
...  

2021 ◽  
Vol 161 ◽  
pp. S428-S429
Author(s):  
Y. Ez-zyouy ◽  
A. Gulyban ◽  
C. Bouchart ◽  
N. Reynaert

2018 ◽  
Vol 63 (12) ◽  
pp. 125005 ◽  
Author(s):  
Yibing Wang ◽  
Steven F Petit ◽  
Eliana Vásquez Osorio ◽  
Vikas Gupta ◽  
Alejandra Méndez Romero ◽  
...  

2016 ◽  
Vol 119 (2) ◽  
pp. 319-325 ◽  
Author(s):  
Antonetta C. Houweling ◽  
Kyohei Fukata ◽  
Yoshiki Kubota ◽  
Hirofumi Shimada ◽  
Coen R.N. Rasch ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document