The relationship between ACL reconstruction, tibial tunnel location, and the anterior aspect of the PCL tibial insertion

2019 ◽  
Vol 29 (8) ◽  
pp. 1749-1758 ◽  
Author(s):  
Takanori Teraoka ◽  
Yusuke Hashimoto ◽  
Shinji Takahashi ◽  
Shinya Yamasaki ◽  
Yohei Nishida ◽  
...  

Author(s):  
Tsuneari Takahashi ◽  
Tomohiro Saito ◽  
Tatsuya Kubo ◽  
Ko Hirata ◽  
Hideaki Sawamura ◽  
...  

AbstractFew studies have determined whether a femoral bone tunnel could be created behind the resident's ridge by using a transtibial (TT) technique-single bundle (SB)-anterior cruciate ligament (ACL) reconstruction. The aim of this study was to clarify (1) whether it is possible to create a femoral bone tunnel behind the resident's ridge by using the TT technique with SB ACL reconstruction, (2) to define the mean tibial and femoral tunnel angles during anatomic SB ACL reconstruction, and (3) to clarify the tibial tunnel inlet location when the femoral tunnel is created behind resident's ridge. Arthroscopic TT-SB ACL reconstruction was performed on 36 patients with ACL injuries. The point where 2.4-mm guide pin was inserted was confirmed, via anteromedial portal, to consider a location behind the resident's ridge. Then, an 8-mm diameter femoral tunnel with a 4.5-mm socket was created. Tunnel positions were evaluated by using three-dimensional computed tomography (3D-CT) 1 week postoperatively. Quadrant method and the resident's ridge on 3D-CT were evaluated to determine whether femoral tunnel position was anatomical. Radiological evaluations of tunnel positions yielded mean ( ±  standard deviation) X- and Y-axis values for the tunnel centers: femoral tunnel, 25.2% ± 5.1% and 41.6% ± 10.2%; tibial tunnel, 49.2% ± 3.5%, and 31.5% ± 7.7%. The bone tunnels were anatomically positioned in all cases. The femoral tunnel angle relative to femoral axis was 29.4 ± 5.5 degrees in the coronal view and 43.5 ± 8.0 degrees in the sagittal view. The tibial tunnel angle relative to tibial axis was 25.5 ± 5.3 degrees in the coronal view and 52.3 ± 4.6 degrees in the sagittal view. The created tibial bone tunnel inlet had an average distance of 13.4 ± 2.7 mm from the medial tibial joint line and 9.7 ± 1.7 mm medial from the axis of the tibia. Femoral bone tunnel could be created behind the resident's ridge with TT-SB ACL reconstruction. The tibial bone tunnel inlet averaged 13.4 mm from the medial tibial joint line and 9.7 mm medial from the tibia axis.


2020 ◽  
Vol 7 (4) ◽  
pp. 206-210
Author(s):  
Shekhar Tank ◽  
Saurabh Dutt ◽  
Rakesh Sehrawat ◽  
Dhananjaya Sabat ◽  
Vinod Kumar

2018 ◽  
Vol 47 (1) ◽  
pp. 132-135 ◽  
Author(s):  
Edoardo Monaco ◽  
Andrea Redler ◽  
Mattia Fabbri ◽  
Lorenzo Proietti ◽  
Edoardo Gaj ◽  
...  

2002 ◽  
Vol 11 (2) ◽  
pp. 128-138 ◽  
Author(s):  
Michael D. Ross ◽  
Shelly Hooten ◽  
Darren Moore

Objective:To determine the relationship between asymmetries in lower leg girth and standing heel-rise after anterior cruciate ligament (ACL) reconstruction.Design:Single-group posttest.Participants:15 at a mean of 30 d after ACL reconstruction.Measurements:Lower leg girth and number of repetitions performed on the standing heel-rise test.Results:A significant decrease in lower leg girth and number of repetitions performed on the standing heel-rise test for the involved leg. There was also a low correlation between asymmetries in lower leg girth and standing heel-rise test (r= .25).Conclusion:Ankle plantar-flexor endurance should be considered when developing rehabilitation programs for the early stages after ACL reconstruction. In this study the ankle of the involved leg attained a significantly smaller angle of maximal standing plantar flexion, suggesting that ankle range of motion should also be assessed. Caution should be used in predicting standing heel-rise asymmetries from asymmetries in lower leg girth in ACL-reconstructed patients.


2018 ◽  
Vol 32 (11) ◽  
pp. 1094-1101
Author(s):  
Jiangyu Cai ◽  
Fang Wan ◽  
Chengchong Ai ◽  
Wenhe Jin ◽  
Dandan Sheng ◽  
...  

AbstractAn enlarged bone tunnel may affect the graft–bone integration and pose a problem for revision anterior cruciate ligament (ACL) surgery. The purpose of this study was to evaluate the effect of remnant preservation on tibial tunnel enlargement in ACL reconstruction with polyethylene terephthalate (PET) artificial ligament. Twenty-four skeletally mature male beagles underwent ACL reconstruction with PET artificial ligament for both knees. One knee was reconstructed with remnant preservation using sleeve technique (remnant group), while the contralateral was reconstructed without remnant preservation (control group). The animals were sacrificed at 1 day, 6 weeks, and 12 weeks after surgery for further evaluation including macroscopic observation, microcomputed tomography (micro-CT), histological assessment, and biomechanical testing. The remnant group had better synovial coverage than the control group at 6 and 12 weeks after surgery. The micro-CT analysis showed the tibial tunnel area (TTA) of the remnant group was significantly smaller and the bone volume/total volume fraction (BV/TV) value was higher than those of the control group at 6 and 12 weeks. Moreover, TTA and BV/TV at each time point were divided into three groups according to the different grade of synovial coverage. Significant association was observed between the synovial coverage degree and the TTA and BV/TV values. The histological assessment revealed that the interface width between the graft and host bone in the remnant group was smaller than that in the control group in the tibial tunnels at 6 and 12 weeks. Moreover, the remnant group had better failure load and stiffness than the control group at 12 weeks. The remnant preservation using sleeve technique could effectively promote the synovial coverage of the graft, decrease the risk of tibial tunnel enlargement by sealing the bone tunnel entrance, and enhance the biological environment for graft–bone healing after ACL reconstruction using PET artificial ligament. This technique provides a potential solution for bone tunnel enlargement following artificial ligament surgery for the acute ACL rupture in the clinical practice.


2012 ◽  
Vol 6 (1) ◽  
pp. 295-300 ◽  
Author(s):  
James Min-Leong Wong ◽  
Tanvir Khan ◽  
Chethan S Jayadev ◽  
Wasim Khan ◽  
David Johnstone

Anterior Cruciate Ligament (ACL) rupture is a common sporting injury that frequently affects young, athletic patients. Apart from the functional problems of instability, patients with ACL deficient knees also develop osteoarthritis. Although this is frequently cited as an indication for ACL reconstruction, the relationship between ACL rupture, reconstruction and the instigation and progression of articular cartilage degenerative change is controversial. The purpose of this paper is to review the published literature with regards ACL rupture and the multifactorial causes for osteoarthritis progression, and whether or not this is slowed or stopped by ACL reconstruction. There is no evidence in the published literature to support the view that ACL reconstruction prevents osteoarthritis, although it may prevent further meniscal damage. It must be recognised that this conclusion is based on the current literature which has substantial methodological limitations.


2018 ◽  
Vol 46 (5) ◽  
pp. 1143-1149 ◽  
Author(s):  
Shaohua Liu ◽  
Hong Li ◽  
Hongyue Tao ◽  
Yaying Sun ◽  
Shiyi Chen ◽  
...  

Background: The hamstring tendons are commonly harvested for anterior cruciate ligament (ACL) reconstruction with detachment of the tibial insertion. Retaining the insertion may help to preserve vascularity and viability of the graft and bypass the stages of avascular necrosis and revascularization, which might be beneficial to graft maturity. Purpose: To investigate and compare graft maturity by magnetic resonance imaging (MRI) after ACL reconstruction with preservation or detachment of hamstring tendon tibial insertion at up to 2 years. Study Design: Randomized controlled trial; Level of evidence, 2. Methods: Forty-five patients (age range, 18-45 years) undergoing isolated ACL reconstruction with hamstring tendon were enrolled and randomized to 2 groups. The tibial insertion of the hamstring tendon was preserved in the study group (n = 21) and detached in the control group (n = 24). Patients had follow-up at 3, 6, 12, and 24 months, which consisted of the following: (1) clinical examination and (2) MRI evaluation of graft signal intensity based on signal/noise quotient (SNQ) values. Finally, 18 patients in the study group and 19 in the control group received full follow-up evaluation (ie, at all 4 time points). Results: All knees acquired full range of motion at 24 months without significant laxity. At each time point, the KT-1000 arthrometer revealed no significant difference between groups; the clinical scores significantly improved in both groups, although the difference between groups was not significant. In the control group, the SNQ value increased from 3 months, peaked at 6 months, and then decreased (3 months, 21.4 ± 12.7; 6 months, 25.6 ± 12; 12 months, 18.3 ± 7.7; 24 months, 15.3 ± 6.3). However, the insertion-preserved graft in the study group maintained relatively lower and unchanged signal intensity throughout all time points (3 months, 15.0 ± 11.2; 6 months, 14.9 ± 6.3; 12 months, 12.6 ± 7.0; 24 months, 14.6 ± 7.0). Between groups, there was no significant difference at 3 or 24 months ( P = .11 and .75, respectively), while the SNQ values were significantly lower in the study group versus the control group at 6 and 12 months ( P = .002 and .02, respectively). Conclusion: The insertion-detached hamstring tendon grafts underwent a significantly increasing change in signal intensity during the first 2 years after ACL reconstruction, while the insertion-preserved grafts kept a relatively lower and unchanged signal intensity. The difference was most significant at 6 and 12 months postoperatively.


Sign in / Sign up

Export Citation Format

Share Document