scholarly journals Intra-operative cone-beam computed tomography for detecting residual stones in percutaneous nephrolithotomy

2020 ◽  
Vol 19 ◽  
pp. e2332
Author(s):  
R.A. Kingma ◽  
M.J.H. Voskamp ◽  
B.H.J. Doornweerd ◽  
I.J. De Jong ◽  
S. Roemeling
Urolithiasis ◽  
2021 ◽  
Author(s):  
R. A. Kingma ◽  
M. J. H. Voskamp ◽  
B. H. J. Doornweerd ◽  
I. J. de Jong ◽  
S. Roemeling

AbstractCone beam computed tomography (CBCT) provides multiplanar cross-sectional imaging and three-dimensional reconstructions and can be used intraoperatively in a hybrid operating room. In this study, we investigated the feasibility of using a CBCT-scanner for detecting residual stones during percutaneous nephrolithotomy (PCNL). Intraoperative CBCT-scans were made during PCNL procedures from November 2018 until March 2019 in a university hospital. At the point where the urologist would have otherwise ended the procedure, a CBCT-scan was made to image any residual fragments that could not be detected by either nephroscopy or conventional C-arm fluoroscopy. Residual fragments that were visualized on the CBCT-scan were attempted to be extracted additionally. To evaluate the effect of this additional extraction, each CBCT-scan was compared with a regular follow-up CT-scan that was made 4 weeks postoperatively. A total of 19 procedures were analyzed in this study. The mean duration of performing the CBCT-scan, including preparation and interpretation, was 8 min. Additional stone extraction, if applicable, had a mean duration of 11 min. The mean effective dose per CBCT-scan was 7.25 mSv. Additional extraction of residual fragments as imaged on the CBCT-scan occurred in nine procedures (47%). Of the follow-up CT-scans, 63% showed a stone-free status as compared to 47% of the intraoperative CBCT-scans. We conclude that the use of CBCT for the detection of residual stones in PCNL is meaningful, safe, and feasible.


Trials ◽  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
R. A. Kingma ◽  
I. J. de Jong ◽  
M. J. W. Greuter ◽  
S. Roemeling

Abstract Introduction Percutaneous nephrolithotomy (PCNL) is the standard surgical treatment method for large kidney stones. Its aim is to achieve a stone-free status, since any residual fragments (RFs) after PCNL are likely to cause additional morbidity or stone growth. Enhancing intraoperative detectability of RFs could lead to increased stone-free rates and decreased re-intervention rates. Cone beam computed tomography (CBCT) has recently been introduced in urology as a feasible method for intraoperatively imaging RFs. The aim of this trial is to determine the added value of CBCT in percutaneous nephrolithotomy, by measuring differences in stone-related morbidity for patients with procedures in which a CBCT is used versus patients with procedures without the use of CBCT. Methods The CAPTURE trial is an investigator-initiated single-center, randomized controlled trial (RCT) in adult patients who have an indication for percutaneous nephrolithotomy. A contemporary percutaneous nephrolithotomy is performed. Once the surgeon is convinced of a stone-free status by means of fluoroscopy and nephroscopy, randomization allocates patients to either the study group in whom an intraoperative CBCT scan is performed or to the control group in whom no intraoperative CBCT scan is performed. The main endpoint is the stone-free status as assessed four weeks postoperatively by low-dose non-contrast abdominal CT, as a standard follow-up procedure. Secondary endpoints include the number of PCNL procedures required and the number of stone-related events (SREs) registered. The total study population will consist of 320 patients that undergo PCNL and are eligible for randomization for an intraoperative CBCT scan. Discussion We deem a randomized controlled trial to be the most effective and reliable method to assess the efficacy of CBCT in PCNL. Though some bias may occur due to the impossibility of blinding the urologist at randomization, we estimate that the pragmatic nature of the study, standardized circumstances, and follow-up methods with pre-defined outcome measures will result in a high level of evidence. Trial registration Netherlands Trial Register (NTR) NL8168, ABR NL70728.042.19. Registered on 15 October 2019. Prospectively registered.


2019 ◽  
Vol 1 (1) ◽  
pp. 16-18 ◽  
Author(s):  
Norafida Bahari ◽  
Nik Azuan Nik Ismail ◽  
Jegan Thanabalan ◽  
Ahmad Sobri Muda

In this article, we evaluate the effectiveness of Cone Beam Computed Tomography, through a case study, in assessing the complication of intracranial bleeding during an endovascular treatment of brain arteriovenous malformation when compared to Multislice-Detector Computed Tomography performed immediately after the procedure. The image quality of Cone Beam Computed Tomography has enough diagnostic value in differentiating between haemorrhage, embolic materials and the arteriovenous malformation nidus to facilitate physicians to decide for further management of the patient.


Author(s):  
Norafida Bahari ◽  
NikAzuan Nik Ismail ◽  
Jegan Thanabalan ◽  
Ahmad Sobri Muda

In this article, we evaluate the effectiveness of Cone Beam Computed Tomography, through a case study, in assessing the complication of intracranial bleeding during an endovascular treatment of brain arteriovenous malformation when compared to Multislice-Detector Computed Tomography performed immediately after the procedure. The image quality of Cone Beam Computed Tomography has enough diagnostic value in differentiating between haemorrhage, embolic materials and the arteriovenous malformation nidus to facilitate physicians to decide for further management of the patient.


Sign in / Sign up

Export Citation Format

Share Document