Broadband Infrared Spectroscopy of Molecules in Solutions with Two Intrapulse Difference-Frequency-Generated Mid-Infrared Frequency Combs

Author(s):  
Noh Soo Han ◽  
JunWoo Kim ◽  
Tai Hyun Yoon ◽  
Minhaeng Cho
Author(s):  
Daniel L. Maser ◽  
Flavio C. Cruz ◽  
Gabriel Ycas ◽  
Todd Johnson ◽  
Andrew Klose ◽  
...  

2018 ◽  
Vol 90 (17) ◽  
pp. 10494-10500 ◽  
Author(s):  
Jessica L. Klocke ◽  
Markus Mangold ◽  
Pitt Allmendinger ◽  
Andreas Hugi ◽  
Markus Geiser ◽  
...  

2013 ◽  
Vol 21 (8) ◽  
pp. 9238 ◽  
Author(s):  
Chun-Chieh Liao ◽  
Yu-Hung Lien ◽  
Kuo-Yu Wu ◽  
Yan-Rung Lin ◽  
Jow-Tsong Shy

2015 ◽  
Vol 23 (20) ◽  
pp. 26814 ◽  
Author(s):  
Flavio C. Cruz ◽  
Daniel L. Maser ◽  
Todd Johnson ◽  
Gabriel Ycas ◽  
Andrew Klose ◽  
...  

Author(s):  
Alessio Gambetta ◽  
Nicola Coluccelli ◽  
Marco Cassinerio ◽  
Paolo Laporta ◽  
Gianluca Galzerano ◽  
...  

2011 ◽  
Vol 28 (1) ◽  
pp. 33-48 ◽  
Author(s):  
Oto Hanuš ◽  
Václava Genčurová ◽  
Yunhai Zhang ◽  
Pavel Hering ◽  
Jaroslav Kopecký ◽  
...  

Milk acetone determination by the photometrical method after microdiffusion and via FT infra-red spectroscopyMilk acetone (AC) and betahydroxybutyrate (BHB) are important indicators of the energy metabolism of cows (ketosis occurrence) and an effective method for their determination, with reliable results, is of great importance. The goal of this work was to investigate the infrared method MIR-FT in terms of its calibration for milk AC and to develop a usable procedure. The microdiffusion photometric (485 nm; Spekol 11) method was used with salicylaldehyde as a reference (Re) and mid infrared spectroscopy FT (MIR-FT: Lactoscope FT-IR, Delta; MilkoScan FT 6000, M-Sc) as an indirect method. The acetone addition to milk had no recovery using MIR-FT (Delta). The reference AC set must have acceptable statistics for good MIR-FT calibration (M-Sc) and they were: 10.1 ± 9.74 at a geometric mean of 7.26 mg l-1, and a variation range from 1.98 to 33.66 mg l-1. The AC correlation between Re and MIR-FT (Delta) was low at 0.32 (P>0.05 but the Log AC relationship between Re and MIR-FT (M-Sc) was markedly better at 0.80 (P<0.01). The conversion of >10 mg l-1 as an AC subclinical ketosis limit could be > -0.80 (feedback 0.158 mmol l-1 = 9.25 mg l-1) and > -1.66. This could be important for ketosis monitoring (using M-Sc).


2021 ◽  
Vol 164 ◽  
pp. 106029
Author(s):  
Diego Maciel Gerônimo ◽  
Sheila Catarina de Oliveira ◽  
Frederico Luis Felipe Soares ◽  
Patricio Peralta-Zamora ◽  
Noemi Nagata

Sign in / Sign up

Export Citation Format

Share Document