scholarly journals Shorting Factor In‐Flight Calibration for the Van Allen Probes DC Electric Field Measurements in the Earth's Plasmasphere

2019 ◽  
Vol 6 (4) ◽  
pp. 646-654 ◽  
Author(s):  
Solène Lejosne ◽  
F. S. Mozer
2013 ◽  
Vol 41 (12) ◽  
pp. 3459-3470
Author(s):  
Dale C. Ferguson ◽  
David Cooke ◽  
Robert Pfaff ◽  
Douglas Rowland ◽  
Jeffrey Klenzing ◽  
...  

2020 ◽  
Author(s):  
Wenlong Liu ◽  
Zhao Zhang

<p>Corotation electric field is important in the inner magnetosphere topology, which was usually calculated by assuming 24h corotation period. However, some studies suggested that plasmasphere corotation lag exists which leads to the decrease of corotation electric field. In this study, we use electric field measurements from Van Allen Probes mission from 2013 to 2017 to statistically calculate the distribution of large-scale electric field in the inner magnetosphere. A new method is subsequently developed to separate corotation electric field from convection electric field. Our research shows electric field is inversely proportional to the square of L, and, with the assumption of dipole magnetic field, the rotation period of plasmasphere is estimated as 27h, consistent to the results by Sandel et al. [2003] and Burch et al. [2004] with EUV imaging of the plasmasphere. Based on the research, a new empirical model of innermagnetospheric corotation electric field was estibalished, which is significant for a more accurate understanding the large-scale electric field in the inner magnetosphere.</p>


1997 ◽  
Vol 24 (13) ◽  
pp. 1695-1698 ◽  
Author(s):  
J.-M. Jahn ◽  
J. LaBelle ◽  
R. F. Pfaff

Author(s):  
Y. V. Khotyaintsev ◽  
P.-A. Lindqvist ◽  
C. M. Cully ◽  
A. I. Eriksson ◽  
M. André

Abstract. Double-probe electric field instrument with long wire booms is one of the most popular techniques for in situ measurement of DC and AC electric fields in plasmas on spinning spacecraft platforms, which have been employed on a large number of space missions. Here we present an overview of the calibration procedure used for the EFW instrument on Cluster, which involves spin fits of the data and correction of several offsets. We also describe the procedure for the offset determination and present results for the long-term evolution of the offsets.


Sensors ◽  
2018 ◽  
Vol 18 (6) ◽  
pp. 1740 ◽  
Author(s):  
Ya Mou ◽  
Zhanqing Yu ◽  
Kaitian Huang ◽  
Qing Ma ◽  
Rong Zeng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document