scholarly journals Higher CPAP levels improve functional residual capacity at birth in preterm rabbits

Author(s):  
Tessa Martherus ◽  
Michelle K. Croughan ◽  
Kelly J. Crossley ◽  
Megan J. Wallace ◽  
Erin V. McGillick ◽  
...  
1999 ◽  
Vol 45 (4, Part 2 of 2) ◽  
pp. 211A-211A
Author(s):  
Cindy T McEvoy ◽  
Susan C Bowling ◽  
Kathleen M Williamson ◽  
Pam McGaw ◽  
M Durand

1979 ◽  
Vol 46 (5) ◽  
pp. 867-871 ◽  
Author(s):  
A. Vinegar ◽  
E. E. Sinnett ◽  
D. E. Leith

Awake mice (22.6--32.6 g) were anesthetized intravenously during head-out body plethysmography. One minute after pentobarbital sodium anesthesia, tidal volume had fallen from 0.28 +/- 0.04 to 0.14 +/- 0.02 ml and frequency from 181 +/- 20 to 142 +/- 8. Functional residual capacity (FRC) decreased by 0.10 +/- 0.02 ml. Expiratory flow-volume curves were linear, highly repeatable, and submaximal over substantial portions of expiration in awake and anesthetized mice; and expiration was interrupted at substantial flows that abruptly fell to and crossed zero as inspiration interrupted relaxed expiration. FRC is maintained at a higher level in awake mice due to a higher tidal volume and frequency coupled with expiratory braking (persistent inspiratory muscle activity or increased glottal resistance). In anesthetized mice, the absence of braking, coupled with reductions in tidal volume and frequency and a prolonged expiratory period, leads to FRCs that approach relaxation volume (Vr). An equation in derived to express the difference between FRC and Vr in terms of the portion of tidal volume expired without braking, the slope of the linear portion of the expiratory flow-volume curve expressed as V/V, the time fraction of one respiratory cycle spent in unbraked expiration, and respiratory frequency.


2017 ◽  
Vol 123 (6) ◽  
pp. 1545-1554 ◽  
Author(s):  
Per M. Gustafsson ◽  
Lovisa Bengtsson ◽  
Anders Lindblad ◽  
Paul D. Robinson

The detrimental effects on breathing pattern during multiple breath inert gas washout (MBW) have been described with different inhaled gases [100% oxygen (O2) and sulfur hexafluoride (SF6)] but detailed comparisons are lacking. N2- and SF6-based tests were performed during spontaneous quiet sleep in 10 healthy infants aged 0.7–1.3 yr using identical hardware. Differences in breathing pattern pre and post 100% O2 and 4% SF6 exposure were investigated, and the results obtained were compared [functional residual capacity (FRC) and lung clearance index (LCI)]. During 100% O2 exposure. mean inspiratory flow (“respiratory drive”) decreased transiently by mean (SD) 28 (9)% ( P < 0.001), and end-tidal CO2 (carbon dioxide) increased by mean (SD) 0.3 (0.4)% units ( P < 0.05) vs. air breathing prephase. During subsequent N2 washin (i.e., recovery phase), the pattern of change reversed. No significant effect on breathing pattern was observed during SF6 testing. In vitro testing confirmed that technical artifacts did not explain these changes. Mean (SD) FRC and LCI in vivo were significantly higher with N2 vs. SF6 washout: 216 (33) vs. 186 (22) ml ( P < 0.001) and 8.25 (0.85) vs. 7.55 (0.57) turnovers ( P = 0.021). Based on these results, SF6 based MBW is the preferred methodology for tests in this age range. NEW & NOTEWORTHY Inert gas choice for multiple breath inert gas washout (MBW) in infants has important consequences on both breathing pattern during test performance and the functional residual capacity and lung clearance index values obtained. Data suggest the detrimental effect of breathing pattern of 100% O2 and movement of O2 across the alveolar capillary membrane, with direct effects on MBW outcomes. SF6 MBW during infancy avoids this and can be further optimized by addressing the sources of technical artifact identified in this work.


1991 ◽  
Vol 70 (6) ◽  
pp. 2611-2618 ◽  
Author(s):  
T. Mutoh ◽  
W. J. Lamm ◽  
L. J. Embree ◽  
J. Hildebrandt ◽  
R. K. Albert

Abdominal distension (AD) occurs in pregnancy and is also commonly seen in patients with ascites from various causes. Because the abdomen forms part of the "chest wall," the purpose of this study was to clarify the effects of AD on ventilatory mechanics. Airway pressure, four (vertical) regional pleural pressures, and abdominal pressure were measured in five anesthetized, paralyzed, and ventilated upright pigs. The effects of AD on the lung and chest wall were studied by inflating a liquid-filled balloon placed in the abdominal cavity. Respiratory system, chest wall, and lung pressure-volume (PV) relationships were measured on deflation from total lung capacity to residual volume, as well as in the tidal breathing range, before and 15 min after abdominal pressure was raised. Increasing abdominal pressure from 3 to 15 cmH2O decreased total lung capacity and functional residual capacity by approximately 40% and shifted the respiratory system and chest wall PV curves downward and to the right. Much smaller downward shifts in lung deflation curves were seen, with no change in the transdiaphragmatic PV relationship. All regional pleural pressures increased (became less negative) and, in the dependent region, approached 0 cmH2O at functional residual capacity. Tidal compliances of the respiratory system, chest wall, and lung were decreased 43, 42, and 48%, respectively. AD markedly alters respiratory system mechanics primarily by "stiffening" the diaphragm/abdomen part of the chest wall and secondarily by restricting lung expansion, thus shifting the lung PV curve as seen after chest strapping. The less negative pleural pressures in the dependent lung regions suggest that nonuniformities of ventilation could also be accentuated and gas exchange impaired by AD.


Sign in / Sign up

Export Citation Format

Share Document