Equivalent Noise Dose Obtained Through Hearing Aids in the Classrooms of Hearing-Impaired Children

1990 ◽  
Vol 21 (3) ◽  
pp. 147-150
Author(s):  
Ronald A. Wilde

A commercial noise dose meter was used to estimate the equivalent noise dose received through high-gain hearing aids worn in a school for deaf children. There were no significant differences among nominal SSPL settings and all SSPL settings produced very high equivalent noise doses, although these are within the parameters of previous projections.

2011 ◽  
Vol 68 (4) ◽  
pp. 349-352 ◽  
Author(s):  
Sanja Ostojic ◽  
Sanja Djokovic ◽  
Nadezda Dimic ◽  
Branka Mikic

Bacground/Aim. Almost 200 cochlear implantations were done in the four centers (two in Belgrade, per one in Novi Sad and Nis) in Serbia from 2002 to 2009. Less than 10% of implantees were postlingually deaf adults. The vast majority, i.e. 90% were pre- and perilingually profoundly deaf children. The aim of this study was to assess the influence of improved auditory perception due to cochlear implantation on comprehension of abstract words in children as compared with hearing impaired children with conventional hearing aids and normal hearing children. Methods. Thirty children were enrolled in this study: 20 hearing impaired and 10 normal hearing. The vocabulary test was used. Results. The overall results for the whole test (100 words) showed a significant difference in favor of the normal hearing as compared with hearing impaired children. The normal hearing children successfully described or defined 77.93% of a total of 100 words. Success rate for the cochlear implanted children was 26.87% and for the hearing impaired children with conventional hearing aids 20.32%. Conclusion. Testing for abstract words showed a statistically significant difference between the cochlear implanted and the hearing impaired children with hearing aids (Mann- Whitney U-test, p = 0.019) implying considerable advantage of cochlear implants over hearing aids regarding successful speech development in prelingually deaf children.


1988 ◽  
Vol 31 (2) ◽  
pp. 156-165 ◽  
Author(s):  
P. A. Busby ◽  
Y. C. Tong ◽  
G. M. Clark

The identification of consonants in a/-C-/a/nonsense syllables, using a fourteen-alternative forced-choice procedure, was examined in 4 profoundly hearing-impaired children under five conditions: audition alone using hearing aids in free-field (A),vision alone (V), auditory-visual using hearing aids in free-field (AV1), auditory-visual with linear amplification (AV2), and auditory-visual with syllabic compression (AV3). In the AV2 and AV3 conditions, acoustic signals were binaurally presented by magnetic or acoustic coupling to the subjects' hearing aids. The syllabic compressor had a compression ratio of 10:1, and attack and release times were 1.2 ms and 60 ms. The confusion matrices were subjected to two analysis methods: hierarchical clustering and information transmission analysis using articulatory features. The same general conclusions were drawn on the basis of results obtained from either analysis method. The results indicated better performance in the V condition than in the A condition. In the three AV conditions, the subjects predominately combined the acoustic parameter of voicing with the visual signal. No consistent differences were recorded across the three AV conditions. Syllabic compression did not, therefore, appear to have a significant influence on AV perception for these children. A high degree of subject variability was recorded for the A and three AV conditions, but not for the V condition.


1978 ◽  
Vol 43 (3) ◽  
pp. 348-352 ◽  
Author(s):  
Robert E. Jirsa ◽  
Thomas W. Norris

Aided threshold improvement obtained by 12 hearing-impaired children was compared to the acoustic gain of their hearing aids using both the traditional 2-cc coupler and a variable volume coupler designed to approximate real ear volume in children. Results indicated that acoustic gain determined in the 2-cc coupler underestimated aided threshold improvement by approximately 8.7 dB. Use of the variable volume coupler to determine acoustic gain, however, adequately predicted aided improvement at comfort setting. Use of the variable volume coupler in hearing-aid fittings for children is discussed with special emphasis on preventing over-amplification.