Finite Element Analysis of a Passive Magnetic Fault Current Limiter using Adaptive Meshing

Author(s):  
S. Das ◽  
A. B. Choudhury ◽  
T. Santra ◽  
T. Sankar Daphadar
2020 ◽  
Author(s):  
Gabriel Dos Santos ◽  
Flávio Goulart dos Reis Martins ◽  
Bárbara Maria Oliveira Santos ◽  
Daniel Henrique Nogueira Dias ◽  
Guilherme Gonçalves Sotelo ◽  
...  

Nowadays, the complexity of electrical power systems is increasing. Consequently, the occurrence and the amplitude of the fault current are rising. This fault currents harm the substations’ electrical equipment. Besides, the growth in the fault current level is forcing the change of the circuit breakers to others with a higher interruption capability. A proposal to solve this problem is the fault current limiter (FCL). This equipment has low impedance in the normal operation and high impedance in a short circuit moment. Superconductors are an advantageous choice of material in this case, because of their properties. In order to simulate this equipment, the 2-D Finite Element Method (FEM) has been used. In this paper, a novel FEM simulation analysis of the saturated core Superconductor Fault Current Limiter (SFCL) is proposed using the A-V-H formulation. The current distribution in the superconducting coil is observed. The results are compared to the limited fault current measurements and simulations available in the literature.


2007 ◽  
Vol 20 (4) ◽  
pp. 338-344 ◽  
Author(s):  
J Duron ◽  
F Grilli ◽  
L Antognazza ◽  
M Decroux ◽  
B Dutoit ◽  
...  

2013 ◽  
Vol 389 ◽  
pp. 1089-1095
Author(s):  
Jun Zhen Peng ◽  
Kun Nan Cao ◽  
Da Da Wang ◽  
Meng Song ◽  
Nan Nan Hu ◽  
...  

As one of the most applicable to high-voltage network superconducting fault current limiterSCFCL(saturated core superconducting fault current limiter) ,which use of core saturation properties can be achieved the current-limiting function without delay ,will be the most widely applied in the future,By analyzing the working principle of SCFCL,this paper use of PSCAD and finite element analysis software Ansoft to build the 500kV\/3150A grade SCFCL model and accurate calculation coil self-inductance and mutual inductance, the harmonic of each size and analyzed its Impedance characteristic on the different external parameters,The results show that SCFCL has a excellent performance for high voltage power network short-circuit current limitation, and provides important reference for design.


2002 ◽  
Vol 382 (1) ◽  
pp. 127-131 ◽  
Author(s):  
E.S Otabe ◽  
M Migita ◽  
M Watanabe ◽  
T Matsushita ◽  
M Morita