scholarly journals Improving the stability of power transmission lines based on an adaptive single pole auto-reclosure using a two-step strategy

2020 ◽  
Vol 14 (5) ◽  
pp. 873-882 ◽  
Author(s):  
Mohsen Jannati ◽  
Mahdi Yazdan Nazari
Author(s):  
Pham Van Kien Pham

Vietnam\'s electricity system has been increasingly invested in development, meeting the growth rate of energy consumption demand in all socio-economic aspects. In particular, the energization and commission of solar and wind power plants greatly affect the stability and safety of the Vietnam power system. To improve the system\'s stability when incidents occur, one of the current solutions is to coordinate relay calibration settings which have a rapid reaction time at all voltage levels. To meet the above requirements, an option is to use Intelligent Electronic Device (IED) with fast processing speed, reduced latency, and multiple functions with intelligent algorithms. In addition, the solution to coordinate the protection areas between IEDs is being concerned. This paper presents the coordination of Permissive Over-Reaching Transfer Trip (POTT) interlock function of SEL 311L relay for power transmission lines to reduce the fault clearing time compared to the traditional calculation method.


Complexity ◽  
2020 ◽  
Vol 2020 ◽  
pp. 1-19
Author(s):  
Changliang Xu ◽  
Zhong Yang ◽  
Zhao Zhang ◽  
Hao Xu ◽  
Jiying Wu ◽  
...  

Tree branches near the electric power transmission lines are of great threat to the electricity supply. Nowadays, the tasks of clearing threatening tree branches are still mostly operated by hand and simple tools. Traditional structures of the multirotor aerial robot have the problem of fixed structure and limited performance, which affects the stability and efficiency of pruning operation. In this article, in order to obtain better environmental adaptability, an active deformable trees-pruning aerial robot is presented. The deformation of the aerial robot is implemented through two ways, arm telescopic and folding. In order to suppress the influence of internal and external disturbances on the system, Active Disturbance Rejection Control (ADRC) technology is adopted to build the flight controller. Firstly, active deformation aerial robot structure is given, followed by system dynamic model establishment under wind disturbance using the Newton–Euler method. Also, the analysis of the gusts influence on the system is considered. Then, the active deformation aerial robot system is decoupled into a combination of six SISO systems, so that a disturbance rejection controller is designed. Finally, the expanded state observer and the nonlinear state error feedback law are used to inspect and compensate the disturbance. Simulation results of attitude and position tracking as well as the antidisturbance capability show that the active deformation aerial robot with the ADRC flight controller designed in this paper has excellent attitude control capabilities during flight and trees-pruning operation.


2016 ◽  
Vol 2016 (4) ◽  
pp. 8-10 ◽  
Author(s):  
B.I. Kuznetsov ◽  
◽  
A.N. Turenko ◽  
T.B. Nikitina ◽  
A.V. Voloshko ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1561
Author(s):  
Hao Chen ◽  
Zhongnan Qian ◽  
Chengyin Liu ◽  
Jiande Wu ◽  
Wuhua Li ◽  
...  

Current measurement is a key part of the monitoring system for power transmission lines. Compared with the conventional current sensor, the distributed, self-powered and contactless current sensor has great advantages of safety and reliability. By integrating the current sensing function and the energy harvesting function of current transformer (CT), a time-multiplexed self-powered wireless sensor that can measure the power transmission line current is presented in this paper. Two operating modes of CT, including current sensing mode and energy harvesting mode, are analyzed in detail. Through the design of mode-switching circuit, harvesting circuit and measurement circuit are isolated using only one CT secondary coil, which eliminates the interference between energy harvesting and current measurement. Thus, the accurate measurement in the current sensing mode and the maximum energy collection in the energy harvesting mode are both realized, all of which simplify the online power transmission line monitoring. The designed time-multiplexed working mode allows the sensor to work at a lower transmission line current, at the expense of a lower working frequency. Finally, the proposed sensor is verified by experiments.


IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Vedanta Pradhan ◽  
O. D. Naidu ◽  
Sinisa Zubic ◽  
Patrick Cost

Author(s):  
Ronaldo F. R. Pereira ◽  
Felipe P. Albuquerque ◽  
Luisa H. B. Liboni ◽  
Eduardo C. M. Costa ◽  
Mauricio C. de Oliveira

Sign in / Sign up

Export Citation Format

Share Document