Quantification of Liver Glucose Metabolism by Positron Emission Tomography: Validation Study in Pigs

2007 ◽  
Vol 132 (2) ◽  
pp. 531-542 ◽  
Author(s):  
Patricia Iozzo ◽  
Mikko J. Jarvisalo ◽  
Jan Kiss ◽  
Ronald Borra ◽  
Gratian A. Naum ◽  
...  
1999 ◽  
Vol 41 (6) ◽  
pp. 689-692 ◽  
Author(s):  
ZENICHIRO Kato ◽  
KANJI Yasuda ◽  
KAZUNARI Ishii ◽  
HAJIME Takagi ◽  
SHINJI Mizuno ◽  
...  

1987 ◽  
Vol 7 (2) ◽  
pp. 214-229 ◽  
Author(s):  
K. Herholz ◽  
C. S. Patlak

An analytical method based on Taylor expansions was developed to analyze errors caused by tissue heterogeneity in dynamic positron emission tomography (PET) measurements. Some general rules concerning the effect of parameter variances and covariances were derived. The method was further applied to various compartmental models currently used for measurement of blood flow, capillary permeability, glucose metabolism, and tracer binding. Blood flow and capillary permeability are shown to be generally underestimated in heterogenous tissue, the underestimation being more severe for slowly decaying, constant or increasing input functions rather than for bolus input, and increasing with measurement time. Typical errors caused by the heterogeneity due to insufficient separation between gray and white matter by a PET scanner with full width at half-maximum (FWHM)= 5 to 10 mm resolution range between–0.9 and–6% in dynamic CBF measurements with intravenous (i. v.) bolus injection of 15O-water or inhalation of 18F-fluoromethane and total measurement times of6 or 10 min, respectively. Binding or metabolic rates determined with tracers that are essentially trapped in tissue (e.g., FDG for measurement of cerebral glucose metabolism) are only slightly overestimated (0.5–3.0%) at typical measurement times and are essentially independent of the shape of the input function. The error increases considerably if tracer accumulation is very slow, however, or if short measurement times [<5/(k2 + k3)] are used. Some rate constants are also subject to larger errors.


2020 ◽  
Vol 21 (18) ◽  
pp. 6523
Author(s):  
Maria Vittoria Mattoli ◽  
Giorgio Treglia ◽  
Maria Lucia Calcagni ◽  
Annunziato Mangiola ◽  
Carmelo Anile ◽  
...  

Idiopathic normal pressure hydrocephalus (iNPH) is the only form of dementia that can be cured by surgery. Its diagnosis relies on clinical and radiological criteria. Identifying patients who can benefit from surgery is challenging, as other neurological diseases can be concomitant or mimic iNPH. We performed a systematic review on the role of positron emission tomography (PET) in iNPH. We retrieved 35 papers evaluating four main functional aspects with different PET radiotracers: (1) PET with amyloid tracers, revealing Alzheimer’s disease (AD) pathology in 20–57% of suspected iNPH patients, could be useful in predictions of surgical outcome. (2) PET with radiolabeled water as perfusion tracer showed a global decreased cerebral blood flow (CBF) and regional reduction of CBF in basal ganglia in iNPH; preoperative perfusion parameters could predict surgical outcome. (3) PET with 2-Deoxy-2-[18F]fluoroglucose ([18F]FDG ) showed a global reduction of glucose metabolism without a specific cortical pattern and a hypometabolism in basal ganglia; [18F]FDG PET may identify a coexisting neurodegenerative disease, helping in patient selection for surgery; postsurgery increase in glucose metabolism was associated with clinical improvement. (4) Dopaminergic PET imaging showed a postsynaptic D2 receptor reduction and striatal upregulation of D2 receptor after treatment, associated with clinical improvement. Overall, PET imaging could be a useful tool in iNPH diagnoses and treatment response.


Sign in / Sign up

Export Citation Format

Share Document