Thyroid Disorders and the Distribution of Orally Administered Radioiodine

1977 ◽  
Vol 16 (06) ◽  
pp. 205-213
Author(s):  
H. DaCosta ◽  
B. A. Bagwe

Summary128 control, thyrotoxic, hypothyroid and goitrous euthyroid children were administered 1–2 μCi Na 131I orally and studied in a shadow-shield whole-body counter. 48-hr whole-body counts permitted the differentiation of the first 3 groups (p < 0.005). Ratio of extrathyroid:excreted 131I was 3 times greater in thyrotoxics than in goitrous euthyroids, but the thyroid:extrathyroid ratio was 3 times greater in the latter group. The whole-body profile scan obtained at 48 hr on an attached strip chart recorder, revealed activity not only in the thyroid but even lower down in the vicinity of the knees and feet.

1984 ◽  
Vol 57 (679) ◽  
pp. 581-584 ◽  
Author(s):  
T. K. Hames ◽  
B. R. Condon ◽  
J. S. Fleming ◽  
G. Phillips ◽  
G. Holdstock ◽  
...  

1997 ◽  
Vol 24 (4) ◽  
pp. 398-402
Author(s):  
C. Pirich ◽  
U. Pr�fert ◽  
E. Havlik ◽  
E. Schwarmeis ◽  
J Flores ◽  
...  

2019 ◽  
Vol 23 ◽  
pp. 171
Author(s):  
N. Sarlikiotis ◽  
C. Potiriadis ◽  
M. Nikolaki ◽  
I. E. Stamatelatos

Monte Carlo simulations and verification measurements for the efficiency calibration of the ACCUSCAN shadow-shield type Whole Body Counter (WBC) of the Greek Atomic Energy Commission (EEAE) are presented. A model of the counter and RMC-II anthropomorphic phantom was developed using the MCNP code. Full energy peak efficiencies for different phantom positions were calculated for 60Co and 137Cs sources. The deviations between computational and experimental efficiencies were found to be less than 12 % for 60Co and 4 % for 137Cs for the Ge detector and less than 25 % for 60Co and 4 % for 137Cs for the NaI detector. This work contributes to the accurate quantification of internal contamination in individuals accidentally exposed in Greece by the Greek Atomic Energy Commission Laboratories and moreover demonstrates the effectiveness of using computational tools for understanding the calibration of radiation detection systems used for in vivo monitoring.


2016 ◽  
Vol 39 (2) ◽  
pp. 68
Author(s):  
IS Singh ◽  
Rajesh Sankhla ◽  
DD Rao ◽  
Abhay Kumar ◽  
AK Sinha ◽  
...  

1997 ◽  
Vol 24 (4) ◽  
pp. 398-402 ◽  
Author(s):  
C. Pirich ◽  
U. Prüfert ◽  
E. Havlik ◽  
E. Schwarmeis ◽  
J Flores ◽  
...  

Author(s):  
O. Aviv ◽  
H. B. Spitz ◽  
H. Datz ◽  
G. Haquin ◽  
Y. Shamai ◽  
...  

2021 ◽  
pp. 110020
Author(s):  
M. Manohari ◽  
P. Sugumar ◽  
R. Deepu ◽  
R. Mathiyarasu ◽  
B. Venkatraman

1965 ◽  
Vol 11 (11) ◽  
pp. 1213-1220 ◽  
Author(s):  
H. E. Palmer ◽  
W. C. Roesch

Sign in / Sign up

Export Citation Format

Share Document