gamma camera
Recently Published Documents


TOTAL DOCUMENTS

1879
(FIVE YEARS 136)

H-INDEX

45
(FIVE YEARS 3)

2022 ◽  
Vol 90 (1) ◽  
pp. 51-58
Author(s):  
Mary Lowe ◽  
Alex Spiro ◽  
Peter Kutt

2022 ◽  
Vol 17 (01) ◽  
pp. E01001
Author(s):  
J. Nagata ◽  
S. Yamamoto ◽  
Y. Noguchi ◽  
T. Nakaya ◽  
K. Okudaira ◽  
...  

Abstract The gamma camera has a 1-mm-thick cerium-doped yttrium aluminum perovskite (YA1O_3: YAP(Ce)) scintillator plate optically coupled to a position-sensitive photomultiplier (PSPMT), and a 0.1-mm-diameter pinhole collimator was mounted in front of the camera to improve spatial resolution and reduce sensitivity.


2021 ◽  
Vol 16 (12) ◽  
pp. T12005
Author(s):  
J. Nagata ◽  
S. Yamamoto ◽  
Y. Noguchi ◽  
T. Nakaya ◽  
K. Okudaira ◽  
...  

Abstract In high-dose-rate (HDR) brachytherapy, verification of the Ir-192 source's position during treatment is needed because such a source is extremely radioactive. One of the methods used to measure the source position is based on imaging the gamma rays from the source, but the absolute position in a patient cannot be confirmed. To confirm the absolute position, it is necessary to acquire an optical image in addition to the gamma ray image at the same time as well as the same position. To simultaneously image the gamma ray and optical images, we developed an imaging system composed of a low-sensitivity, high-resolution gamma camera integrated with a CMOS camera. The gamma camera has a 1-mm-thick cerium-doped yttrium aluminum perovskite (YAIO3: YAP(Ce)) scintillator plate optically coupled to a position-sensitive photomultiplier (PSPMT), and a 0.1-mm-diameter pinhole collimator was mounted in front of the camera to improve spatial resolution and reduce sensitivity. We employed the concept of a periscope by placing two mirrors tilted at 45 degrees facing each other in front of the gamma camera to image the same field of view (FOV) for the gamma camera and the CMOS camera. The spatial resolution of the imaging system without the mirrors at 100 mm from the Ir-192 source was 3.2 mm FWHM, and the sensitivity was 0.283 cps/MBq. There was almost no performance degradation observed when the mirrors were positioned in front of the gamma camera. The developed system could measure the Ir-192 source positions in optical and gamma ray images. We conclude that the developed imaging system has the potential to measure the absolute position of an Ir-192 source in real-time clinical measurements.


2021 ◽  
Vol 178 ◽  
pp. 109937
Author(s):  
Seong Ho Jung ◽  
Kyuseok Kim ◽  
Won Seuk Jang ◽  
Hee-Kyo Jeong ◽  
Byeong-Ju Kwon ◽  
...  

2021 ◽  
Vol 11 (11) ◽  
pp. 1164
Author(s):  
Paweł Cichocki ◽  
Michał Błaszczyk ◽  
Kamila Cygulska ◽  
Krzysztof Filipczak ◽  
Zbigniew Adamczewski ◽  
...  

Background: Myocardial blood flow (MBF) and flow reserve (MFR) examination, especially useful in the diagnosis of multivessel coronary artery disease (CAD), can be assessed with a cadmium-zinc-telluride (CZT) SPECT gamma camera, as an alternative to the expensive and less available PET. However, study processing is not free from subjective factors. Therefore, this paper aims to evaluate intra- and interobserver repeatability of MBF and MFR values obtained by the same operator and two independent operators. Methods: This study included 57 adult patients. MBF and MFR were assessed using a Discovery NM530c camera in a two-day, rest/dipyridamople protocol, using 99mTc-MIBI. Data were processed using Corridor4DM software, twice by one operator and once by another operator. Results: The repeatability of the assessed values was quite good in the whole myocardium, LAD and LCX vascular territories, but was poor in the RCA territory. Conclusions: The poor repeatability of MBF and MFR in RCA vascular territory can be explained by poor automatic orientation of the heart axis during post-processing and a so-called “cardiac creep” phenomenon. Better automatic heart orientation and introduction of automatic motion correction is likely to drastically improve this repeatability. In the present state of the software, PET is better for patients requiring assessment of MFR in the RCA territory.


2021 ◽  
pp. jnmt.121.262627
Author(s):  
Hend Komber ◽  
David Little ◽  
Sarah Cade ◽  
Richard Graham ◽  
Stewart Redman

2021 ◽  
Author(s):  
Ching-Hsiu Ke ◽  
Wan-Ju Liu ◽  
Bing-Ru Peng ◽  
Lung-Fa Pan ◽  
Lung-Kwang Pan

Abstract Background: This study optimized the minimum detectable difference (MDD) of gamma camera SPECT images via the Taguchi analysis and an indigenous V-shaped slit gauge. The latter was customized to satisfy the Taguchi analysis’ quantitative requirements. Methods: The slit gauge MDD quantification of derived SPECT images was based on a pair of overlapped-peak profiles obtained from a tangent slice of the V-shaped slit with two adjacent peaks. Using the revised Student’s t-test with a multiplied constant, 1.96, the MDD was defined as the minimum distance between two peak centers, which deviation was large enough to ensure a 95% confidence level of their separation. In total, eighteen combinations of six gamma camera scanned factors (A-F), namely (A) collimator, (B) detector to target distance, (C) total counts, (D) acquired energy width, (E) Matrix size, and (F) zoom of collected ROI with each of two or three levels were organized into 18 groups to collect the slit gauge images according to Taguchi L18 orthogonal array. Next, three well-trained radiologists ranked the scanned gauge images to derive the fish-bone-plot of signal-to-noise ratio (S/N, dB) and correlated ANOVA. Results: The quantified MDD was proposed to verify the optimal suggestion of gamma camera scanned protocol, and obtained the MDD as 8.44, 7.88, and 7.40 mm for the 2nd group of the original L18, conventional, and optimal presets, respectively. Conclusions: The optimal preset of gamma camera was achieved according to Taguchi analysis. The MDD-based approach was found more beneficial in evaluating the spatial resolution than the line pair/cm approach in routine quality control in this study.