scholarly journals Comparison of Functional Results of Patients with an Active Middle Ear Implant (Vibrant Soundbridge) and Semi-Implantable Bone Conduction Device (Bonebridge)

2020 ◽  
Author(s):  
Jennifer L. Spiegel ◽  
Bernhard G. Weiss ◽  
Ivelina Stoycheva ◽  
Martin Canis ◽  
Friedrich Ihler
2020 ◽  
Vol 141 (1) ◽  
pp. 34-38
Author(s):  
Masahiro Takahashi ◽  
Satoshi Iwasaki ◽  
Sakiko Furutate ◽  
Shinichiro Oka ◽  
Shogo Oyamada ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-4 ◽  
Author(s):  
Giovanni Bianchin ◽  
Lorenzo Tribi ◽  
Aronne Reverzani ◽  
Patrizia Formigoni ◽  
Valeria Polizzi

We describe the novel solution adopted in positioning middle ear implant in a child with bilateral congenital aural atresia and craniofacial dysmorphism that have posed a significant challenge for the safe and correct management of deafness. A five-year-old child, affected by a rare congenital disease (Van Maldergem Syndrome), suffered from conductive hearing loss. Conventional skin-drive bone-conduction device, attached with a steel spring headband, has been applied but auditory restoration was not optimal. The decision made was to position Vibrant Soundbridge, a middle ear implant, with an original surgical application due to hypoplasia of the tympanic cavity. Intubation procedure was complicated due to child craniofacial deformities. Postoperative hearing rehabilitation involved a multidisciplinary team, showing improved social skills and language development.


2016 ◽  
Vol 130 (4) ◽  
pp. 404-407 ◽  
Author(s):  
J F Polanski ◽  
A D Soares ◽  
Z M Dos Santos ◽  
O L Mendonça Cruz

AbstractObjective:The Vibrant Soundbridge is an active middle-ear implant for hearing rehabilitation that is usually placed in the long process of the incus or round window. This study reports on the unusual implant attachment to the short process of the incus in a patient with ear malformation, and describes their audiological and clinical outcomes.Methods:Case report and literature review.Results:Audiological evaluation with the Vibrant Soundbridge implant showed a pure tone average of 31 dB. The speech test, at 65 dB HL, revealed correct recognition of 92 per cent of disyllabic words. The Glasgow Hearing Aid Benefit Profile showed high levels of satisfaction, hearing aid use and benefit.Conclusion:Fixation of the Vibrant Soundbridge implant on the short process of the incus is a feasible option, with good clinical and audiological outcomes. Coupling the floating mass transducer to the short process of the incus is a good surgical option, especially when the long process and the oval or round window are inaccessible.


2019 ◽  
Vol 28 (3) ◽  
pp. 553-559 ◽  
Author(s):  
Ute Geiger ◽  
Andreas Radeloff ◽  
Rudolf Hagen ◽  
Mario Cebulla

Purpose This study intraoperatively measured the coupling efficiency of the Vibrant Soundbridge (VSB), with the aim of avoiding revision surgery due to insufficient outcome. This method can also be used to test the integrity of the implant at the end of the implantation surgery and to evaluate aided thresholds. In addition, this method makes it possible to objectively test how well the VSB has been fitted, provide assistance in fitting handicapped patients or children, evaluate hearing degradation, or test for a drop in coupling efficiency before revision surgeries. In order to analyze the feasibility of these new VSB-aided auditory brainstem response (ABR) thresholds, they were compared to behavioral thresholds from the Vibrogram and the preoperative bone conduction thresholds. Method The study included 30 patients with mild-to-severe hearing loss implanted with a VSB (VORP503). Intraoperative ABR thresholds during the VSB implantation were recorded using a VSB-optimized chirp stimulus. The new method is compared to the bone conduction threshold of the study sample and the aided Vibrogram thresholds. Speech intelligibility results up to 24 months after surgery are also presented. Results A reliable correlation between the bone conduction thresholds and the intraoperative ABRs was found and was higher in comparison to the Vibrogram. Furthermore, speech intelligibility outcomes were stable over time. Conclusion ABR measurements can be used intraoperatively to estimate the coupling efficiency of the VSB and test the integrity of the implant at the end of surgery.


2016 ◽  
Vol 21 (6) ◽  
pp. 347-355 ◽  
Author(s):  
Susan Busch ◽  
Thomas Lenarz ◽  
Hannes Maier

The active middle ear implant Vibrant Soundbridge© provides a variety of coupling modalities of the floating mass transducer (FMT) to various structures of the ossicular chain and the round window. A retrospective analysis was performed on 125 subjects (n = 137 ears) (1) to compare the efficacy of the different FMT coupling modalities with increasing degree of hearing loss, (2) to compare the performance in speech outcome and the effective gain between the coupling types, and (3) to evaluate the risk of additional hearing loss of each coupling procedure. The patients were grouped according to their type of FMT coupling into incus vibroplasty (incus group, n = 59), round window vibroplasty with coupler (RWC group, n = 23), round window vibroplasty without coupler (RW group, n = 22), and oval window vibroplasty with coupler (OWC group, n = 33). For each coupling group, pre- and postoperative thresholds, the results of the Freiburg monosyllable test at 65 dB SPL, and the effective gain across frequencies (0.5-6 kHz) were evaluated. A logistic regression function was used to describe the relationship between word recognition scores (WRS, in % correct) and the mean bone conduction (BC) hearing loss. The surgical procedure had no clinically relevant effect on BC thresholds of patients in each coupling group. The BC pure tone average (PTA4) for 50% WRS predicted by the model function was similar for the incus (48.2 dB nHL), RW (47.8 dB nHL), and OWC (49.0 dB nHL) groups, but higher for the RWC group (67.9 dB nHL). However, the median WRS was 80% or better with no significant differences in speech perception between coupling types (Kruskal-Wallis test, p = 0.229). The effective gain shows an advantage for the incus coupling between 0.5 and 2 kHz over the other coupling types. The performance of the FMT coupling modalities is equally good for patients with a mild-to-moderate hearing loss, but the efficacy of coupling types differs for patients with greater hearing loss (>48 dB BC HL).


Sign in / Sign up

Export Citation Format

Share Document