The Active Middle Ear Implant Vibrant Soundbridge: Outcomes on Safety, Efficacy, Effectiveness, and Subjective Benefit 1996–2017

Author(s):  
Michael Urban ◽  
Francesca Scandurra ◽  
Anna Truntschnig ◽  
Severin Fürhapter ◽  
Geoffrey Ball
2020 ◽  
Vol 141 (1) ◽  
pp. 34-38
Author(s):  
Masahiro Takahashi ◽  
Satoshi Iwasaki ◽  
Sakiko Furutate ◽  
Shinichiro Oka ◽  
Shogo Oyamada ◽  
...  

2016 ◽  
Vol 130 (4) ◽  
pp. 404-407 ◽  
Author(s):  
J F Polanski ◽  
A D Soares ◽  
Z M Dos Santos ◽  
O L Mendonça Cruz

AbstractObjective:The Vibrant Soundbridge is an active middle-ear implant for hearing rehabilitation that is usually placed in the long process of the incus or round window. This study reports on the unusual implant attachment to the short process of the incus in a patient with ear malformation, and describes their audiological and clinical outcomes.Methods:Case report and literature review.Results:Audiological evaluation with the Vibrant Soundbridge implant showed a pure tone average of 31 dB. The speech test, at 65 dB HL, revealed correct recognition of 92 per cent of disyllabic words. The Glasgow Hearing Aid Benefit Profile showed high levels of satisfaction, hearing aid use and benefit.Conclusion:Fixation of the Vibrant Soundbridge implant on the short process of the incus is a feasible option, with good clinical and audiological outcomes. Coupling the floating mass transducer to the short process of the incus is a good surgical option, especially when the long process and the oval or round window are inaccessible.


2021 ◽  
pp. 1-8
Author(s):  
Birthe Warnholtz ◽  
Merlin Schär ◽  
Pascale Cuny ◽  
Kathrin Sonntag ◽  
Dirk Beutner ◽  
...  

Introduction: The Vibrant Soundbridge (MED-EL Medical Electronics, Austria) is an active middle ear implant with a floating mass transducer (FMT) for patients with conductive, sensorineural, or mixed hearing loss. While the FMT is vertically aligned above the stapes head (SH) with the current Vibroplasty Clip coupler (MED-EL Medical Electronics), the new SH coupler was developed to mount the FMT on the inferior side of the stapes and to fit in the reduced middle ear space after canal-wall-down mastoidectomy. Methods: Using 11 human cadaveric temporal bones (TBs), placements of the new SH couplers on the stapes were examined, and effective stimuli to the cochlea were evaluated by measuring piston-like motion of the stapes footplate with a current of 1 mA on the FMT. The results were assessed in comparison with the Vibroplasty Clip coupler. Results: The new SH coupler showed perfect coupling on the stapes in 9 out of 11 TBs. A small gap between the SH and the plate of the connection link part was unavoidable in 2 TBs but had negligible effect on vibrational motion of the stapes. Vibrational motion of the stapes with the new SH coupler was reduced at frequencies above 3 kHz compared to the corresponding motion with the current Vibroplasty Clip coupler, but the relative attenuation over all 11 cadaveric temporal bones was <10 dB. Conclusions: The new SH coupler provides an alternative with more stable fixation when placement of the current Vibroplasty Clip coupler is limited due to insufficient space after canal-wall-down mastoidectomy, while still delivering effective stimuli to the cochlea.


2016 ◽  
Vol 37 (7) ◽  
pp. e222-e227 ◽  
Author(s):  
Johannes Schnabl ◽  
Astrid Wolf-Magele ◽  
Stefan Marcel Pok ◽  
Lena Hirtler ◽  
Gertraud Heinz ◽  
...  

2018 ◽  
Vol 129 (2) ◽  
pp. 477-481 ◽  
Author(s):  
Faris F. Brkic ◽  
Dominik Riss ◽  
Alice Auinger ◽  
Barbara Zoerner ◽  
Christoph Arnoldner ◽  
...  

2015 ◽  
Vol 136 (1) ◽  
pp. 23-33 ◽  
Author(s):  
Shouqin Zhao ◽  
Shusheng Gong ◽  
Demin Han ◽  
Hua Zhang ◽  
Xiaobo Ma ◽  
...  