Inferior vena cava thrombosis examined by three-dimensional and color-Doppler ultrasound

2007 ◽  
Vol 45 (05) ◽  
Author(s):  
G Székely ◽  
Á Szilvás ◽  
Á Futó
VASA ◽  
2011 ◽  
Vol 40 (1) ◽  
pp. 57-63 ◽  
Author(s):  
Ding ◽  
Li ◽  
Han ◽  
Wu ◽  
Shui ◽  
...  

Background: To evaluate retrospectively our initial clinical experience of agitation thrombolysis and balloon dilation in the treatment of Budd-Chiari syndrome (BCS) in patients with fresh inferior vena cava (IVC) thrombosis. Patients and methods: Between August 2004 and March 2009, a total of 12 BCS patients with fresh IVC thrombosis were treated with agitation thrombolysis and balloon dilation. Color Doppler ultrasound results, as well as mortality, morbidity, and the clinical outcomes were evaluated immediately after the treatment and at one week and 1, 3, 6, 12 months after the procedure and then annually thereafter. Results: Agitation thrombolysis and balloon dilation were technically successful in all patients, without immediate procedural complications. The inferior vena cavagrams after the procedure demonstrated complete resolution of the IVC thrombi without pulmonary embolism and full patency of the obstructed IVC. Thirty-day mortality was nil. Clinical success was observed in all patients respectively one month after the procedure. As of February 2010, the mean (± SD) follow-up period for the color Doppler ultrasound procedure was 21.7 ± 8.9 months (range, 12 - 32 months). All patients showed complete patency of the treated IVC without thrombosis, restenosis, or reobstruction, and all patients are alive with resolution of the symptoms at the time of this report. Conclusions: Our preliminary results suggest that agitation thrombolysis and balloon dilation may be a feasible approach for patients with BCS and fresh IVC thrombosis. However, larger studies are warranted to confirm these results.


2014 ◽  
Vol 30 (5) ◽  
pp. 569-571 ◽  
Author(s):  
Meggan L. Goodpasture ◽  
Kristen A. Zeller ◽  
John K. Petty

2021 ◽  
pp. 026835552092598
Author(s):  
Jacob J Bundy ◽  
Jeffrey Forris Beecham Chick ◽  
Ravi N Srinivasa ◽  
Kyle J Cooper ◽  
Joseph J Gemmete ◽  
...  

Objective The Simon Nitinol filter is a bi-level filtration device designed for permanent implantation that is no longer commercially available, but may result in similar complications to current commercially available long term indwelling temporary or permanent filters. Complications related to indwelling inferior vena cava filters include inferior vena cava thrombosis, inferior vena cava penetration, filter migration, and filter fracture. There is a paucity of reports describing the technical aspects related to retrieval of Simon Nitinol filters. Materials and methods This study consisted of five patients with Simon Nitinol filters and describes the indication for retrieval, the retrieval techniques used to remove the filters, technical success, complications, and clinical course. Results The indications for retrieval included: abdominal pain ( n = 2; 40%), iliocaval thrombosis ( n = 1; 20%), identification of an intracardiac filter fragment ( n = 1; 20%), and recurrent venous thromboembolic events ( n = 1; 20%). Retrieval techniques included: biopsy forceps ( n = 3; 60%), excimer laser extraction sheaths ( n = 3; 60%), hangman modified loop snares ( n = 3; 60%), rigid endobronchial forceps ( n = 2; 40%), and balloon deflection ( n = 2; 40%). All filters were successfully retrieved. One patient developed a post-procedural intramuscular hematoma near the site of right internal jugular sheath placement. Conclusions Simon Nitinol filters may be retrieved safely and effectively using advanced inferior vena cava filter retrieval techniques.


Author(s):  
L. Lajoie ◽  
A. Lee ◽  
M. Wilderman ◽  
M. Napolitano ◽  
G. Simonian ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document