Design of Circular Thin-Walled Concrete Filled Steel Tubes

2000 ◽  
Vol 126 (11) ◽  
pp. 1295-1303 ◽  
Author(s):  
Martin D. O'Shea ◽  
Russell Q. Bridge
2016 ◽  
Vol 78 (5-4) ◽  
Author(s):  
Clotilda Petrus ◽  
Hanizah Abd Hamid ◽  
Azmi Ibrahim ◽  
Joe Davylyn Nyuin

This paper presents an experimental investigation into the structural behaviour of eccentrically loaded concrete filled, thin walled, steel tubular slender column with tab stiffeners (CFST). The primary parameters studied through the experimental work are load eccentricity and type of stiffeners. Three different types of stiffeners used in this study are longitudinal stiffeners of 10mm height, longitudinal and tab stiffeners of 25mm height and longitudinal and extended tab stiffeners at 40mm. The effects of the stiffeners on the structural behavior were investigated experimentally using 26 specimens of slender CFST, loaded with eccentricity ranging from 0 mm to 60 mm. It was observed that all specimens failed mainly by overall buckling and, the compressive strength and bending strength of the specimens decreases as the applied load eccentricity increases.


2016 ◽  
Vol 98 ◽  
pp. 293-300 ◽  
Author(s):  
Ju Chen ◽  
Jun Wang ◽  
Fang Xie ◽  
Wei-liang Jin

2009 ◽  
Vol 47 (3) ◽  
pp. 271-276 ◽  
Author(s):  
Juan Chen ◽  
Ju Chen ◽  
Wei Liang Jin

2018 ◽  
Vol 15 (1) ◽  
pp. 59
Author(s):  
NAZRUL AZMI AHMAD ZAMRI ◽  
CLOTILDA PETRUS ◽  
AZMI IBRAHIM ◽  
HANIZAH AB HAMID

The application of concrete filled steel tubes (CFSTs) as composite members has widely been used around the world and is becoming popular day by day for structural application especially in earthquake regions. This paper indicates that an experimental study was conducted to comprehend the behaviour of T-stub end plates connected to concrete filled thin-walled steel tube (CFTST) with different types of bolts and are subjected to pullout load. The bolts used are normal type bolt M20 grade 8.8 and Lindapter Hollo-bolt HB16 and HB20. A series of 10 mm thick T-stub end plates were fastened to 2 mm CFTST of 200 mm x 200 mm in cross-section. All of the specimens were subjected to monotonic pull-out load until failure. Based on test results, the Lidapter Hollo-bolts showed better performance compare to normal bolts. The highest ultimate limit load for T-stub end plate fasten with Lindapter Hollo-bolt is four times higher than with normal bolt although all end plates show similar behaviour and failure mode patterns. It can be concluded that T-stub end plate with Lindapter Hollo-bolt shows a better performance in the service limit and ultimate limit states according to the regulations in the design codes.


Sign in / Sign up

Export Citation Format

Share Document