Evaluating the Mixing Mechanism of Outfall Discharges from Municipal Separate Storm Sewer Systems

Author(s):  
Michael H. Woo
Keyword(s):  
2018 ◽  
Vol 78 (11) ◽  
pp. 2279-2287 ◽  
Author(s):  
Qianyi Zhang ◽  
Mohamed Gaafar ◽  
Evan G. R. Davies ◽  
James R. Bolton ◽  
Yang Liu

Abstract Monochloramine (NH2Cl), as the dominant disinfectant in drinking water chloramination, can provide long-term disinfection in distribution systems. However, NH2Cl can also be discharged into storm sewer systems and cause stormwater contamination through outdoor tap water uses. In storm sewer systems, NH2Cl dissipation can occur by three pathways: (i) auto-decomposition, (ii) chemical reaction with stormwater components, and (iii) biological dissipation. In this research, a field NH2Cl dissipation test was conducted with continuous tap water discharge into a storm sewer. The results showed a fast decrease of NH2Cl concentration from the discharge point to the sampling point at the beginning of the discharge period, while the rate of decrease decreased as time passed. Based on the various pathways involved in NH2Cl decay and the field testing results, a kinetic model was developed. To describe the variation of the NH2Cl dissipation rates during the field testing, a time coefficient fT was introduced, and the relationship between fT and time was determined. After calibration through the fT coefficient, the kinetic model described the field NH2Cl dissipation process well. The model developed in this research can assist in the regulation of tap water outdoor discharge and contribute to the protection of the aquatic environment.


2013 ◽  
Vol 67 (12) ◽  
pp. 2712-2718 ◽  
Author(s):  
Jaap Nienhuis ◽  
Cornelis de Haan ◽  
Jeroen Langeveld ◽  
Martijn Klootwijk ◽  
François Clemens

Distributed temperature sensing (DTS) with fiber-optic cables is a powerful tool to detect illicit connections in storm sewer systems. High-frequency temperature measurements along the in-sewer cable create a detailed representation of temperature anomalies due to illicit discharges. The detection limits of the monitoring equipment itself are well-known, but there is little information available on detection limits for the discovery of illicit connections, as in mixing of sewers, and attenuation also plays an important role. This paper describes the results of full-scale experiments aiming to quantify the detection limits for illicit connections under various sewer conditions. Based on the results, a new monitoring set-up for (partially) filled sewer conduits has been proposed.


Sign in / Sign up

Export Citation Format

Share Document