Ion Pairs of 5,5-dimethyl-2-(2-hydroxy-3,5-disulfophenylhydrazo)cyclohexane-1,3-dione with Cationic Surface-Active Substances as Analytical Reagent for Determination of Copper(II)

2010 ◽  
Vol 43 (18) ◽  
pp. 2923-2938 ◽  
Author(s):  
Kamran T. Mahmudov ◽  
Abel M. Maharramov ◽  
Rafiga A. Aliyeva ◽  
Ismayil A. Aliyev ◽  
Maximilian N. Kopylovich ◽  
...  
2011 ◽  
Vol 8 (2) ◽  
pp. 587-593 ◽  
Author(s):  
Maliheh Barazandeh Tehrani ◽  
Effat Souri

A simple and sensitive derivative spectrophotometric method for simultaneous determination of nickel and copper using 6-(2- naphthyl)-2,3-dihydro-1,2,4-triazine-3-thione (NDTT) as a selective analytical reagent was developed. The complexes of metal ions with NDTT were formed immediately in basic media and extracted with chloroform. The zero-crossing measurement technique was found suitable for the direct measurement of the third-derivative value of Ni-NDTT and Cu-NDTT at 501 and 472 nm respectively. Beer’s law is obeyed in the concentration range 1-30 μg/mL for both cations with different ratios. The limit of detection was 0.26 μg/mL and 0.13 μg/mL for copper and nickel respectively. The within day and between day variations showed coefficient of variation (CV%) values less than 2.80 and 2.97 for copper and nickel respectively. The error of the determination method did not exceed 6.50%. Analysis of alloy sample showed that this method can be successfully used for simultaneous determination of Cu and Ni in real samples.


1980 ◽  
Vol 45 (10) ◽  
pp. 2656-2669 ◽  
Author(s):  
Vlastimil Kubáň ◽  
Dagmar Gotzmannová

The spectrophotometric methods of determining Fe(III) ions with Chromazurol S, Eriochromazurol B and Eriochromcyanine R in the presence of cationic, anionic and nonionic tensides were compared using the basic optical and statistical parameters. A method was proposed and developed for the determination of Fe(III) ions using Chromazurol S in blood serum and plasma at pH 4.7-5.0 in a medium of 2 . 10-4M cetylpyridinium bromide and 0.1M pyridine buffer and at pH 6.0-6.5 in a medium of 2 . 10-3M cetylpyridinium bromide and 0.1M hexamethylenetetramine buffer with molar absorption coefficients of 1.31 . 105 and 1.40 . 105, respectively. The determination is sufficiently specific even at pathological concentrations of the other serum components.


2008 ◽  
Vol 59 (1) ◽  
pp. 3-7
Author(s):  
Aurora Reiss ◽  
Mihaela Mureseanu ◽  
Nicolae Muresan

5-Hydroxy-6-mercapto-benzo [a] phenazine (HMBP) is proposed as a sensitive and selective analytical reagent for the extractive spectrophotometric determination of copper (II). Copper reacts with HMBP to give a dark red complex which is soluble in chloroform. The composition of the CuII � HMBP complex is established as 1:2 by Job�s continuous variation method and molar ratio method. The instability constant of the complex calculated by Job�s relation for nonisomolar series is 4.65 . 10-9, at room temperature. The CuII-HMBP complex in chlorophorm shows a maximum absorbance at 495 nm, with molar absorptivity and Sandell�s sensitivity values of 7.39 . 103dm3 mol-1 cm-1 and 0.012 mg cm-2, respectively. Beer�s law is obeyed in the concentration range 0.67 - 26.90 mg mL-1 and the detection limit is 0.59 mg mL-1. A repetition of the method is checked by finding the relative standard deviation (RSD) at 1.00 mg mL-1 CuII of 0.6%. The method is successfully employed for the determination of copper (II) in environmental samples. The reliability of the method is assured by analysing the standard alloys and by inter-comparison of experimental values, using an atomic absorption spectrometer.


1961 ◽  
Vol 10 (3) ◽  
pp. 284-290
Author(s):  
Hideo WATANABE ◽  
Saburô MIYAZAWA ◽  
Katsumi YAMAMOTO ◽  
Shin'ichiro HAKOMORI

Sign in / Sign up

Export Citation Format

Share Document