Determination of low intrinsic clearance in vitro: the benefit of a novel internal standard in human hepatocyte incubations

Xenobiotica ◽  
2018 ◽  
Vol 49 (4) ◽  
pp. 381-387 ◽  
Author(s):  
Ugo Zanelli ◽  
Thomas Michna ◽  
Carl Petersson
2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Liusheng Huang ◽  
Janus Anders Juul Haagensen ◽  
Davide Verotta ◽  
Vincent Cheah ◽  
Alfred M. Spormann ◽  
...  

It is well known that ion-pairing reagents cause ion suppression in LC-MS/MS methods. Here, we report that trichloroacetic acid increases the MS signal of tobramycin. To support studies of an in vitro pharmacokinetic/pharmacodynamic simulator for bacterial biofilms, an LC-MS/MS method for determination of tobramycin in M9 media was developed. Aliquots of 25 μL M9 media samples were mixed with the internal standard (IS) tobramycin-d5 (5 µg/mL, 25 µL) and 200 µL 2.5% trichloroacetic acid. The mixture (5 µL) was directly injected onto a PFP column (2.0 × 50 mm, 3 µm) eluted with water containing 20 mM ammonium formate and 0.14% trifluoroacetic acid and acetonitrile containing 0.1% trifluoroacetic acid in a gradient mode. ESI+ and MRM with ion m/z 468 → 324 for tobramycin and m/z 473 → 327 for the IS were used for quantification. The calibration curve concentration range was 50–25000 ng/mL. Matrix effect from M9 media was not significant when compared with injection solvents, but signal enhancement by trichloroacetic acid was significant (∼3 fold). The method is simple, fast, and reliable. Using the method, the in vitro PK/PD model was tested with one bolus dose of tobramycin.


2004 ◽  
Vol 72 (2) ◽  
pp. 143-155 ◽  
Author(s):  
M. Sultan ◽  
H. Abdine ◽  
N. Zoman ◽  
F. Belal

A reversed-phase HPLC method with spectrophotometric detection was developed for the simultaneous determination of labetalol (LBT) and hydrochloro-thiazide (HCD). The chromatographic separation was performed using a Microbondapak C18 column (4.6 i.d. x 250 nm) and paracetamol as internal standard. A mobile phase consisting of 0.05 M phosphate buffer/acetonitrile of pH 4 (7:3) at a flow rate of 0.7 ml/min was used. The detection was affected spectrophotornetrically at 302 nm. The working concentration range was 0.3–10 µg/ml with detection limits of 0.05 µg/ml for both drugs. The lower quantitation limit was 0.25 µg/ml in the two cases. The method was successfully applied to tablets, the % recoveries were 99.45 ± 0.68 for LBT and 99.79 ± 0.75 for HCD. The method was extended to the in-vitro determination in spiked human plasma. The % recoveries were 91.12 ± 0.33 for LBT and 91.37 ± 0.40 for HCD. The interday and intraday precision and accuracy were evaluated in plasma by calculating the % RSD (n=5) and the % error and were found to be in the ranges of 1.18–4.1% and 0.38–0.36% for both drugs, respectively.


Planta Medica ◽  
2010 ◽  
Vol 76 (12) ◽  
Author(s):  
W Jülich ◽  
J Pörksen ◽  
H Welzel ◽  
U Lindequist
Keyword(s):  

Planta Medica ◽  
2013 ◽  
Vol 79 (13) ◽  
Author(s):  
GN Ndlovu ◽  
G Fouche ◽  
W Cordier ◽  
V Steenkamp ◽  
M Tselanyane

Sign in / Sign up

Export Citation Format

Share Document